background image

Microframe Corporation

Series 3061 - DataTrack Waiter Call

10

3  SYSTEM OVERVIEW

3.1 DESCRIPTION

The Scope DataTrack Waiter Call is a desk-

top or wall mount radio transcoder that can be

used to transmit numeric and multi-call/pulsed

vibrate messages direct to pagers carried by

individuals or entire groups.  The system has 14

individual call buttons that can transmit any of

three different call types direct to the user’s

pager.

3.2 RANGE EXPANSION

The range and performance of this equip-

ment can be improved by the addition of more

efficient antennas.* These can be installed

either inside or outside the building and are

connected to the transmitter with 50 OHM

coaxial cable.

The center-fed half wave dipole, measuring

approximately 12 inches from tip to tip, will

provide excellent all round local signaling.  It is

a light duty antenna suitable for sheltered

environments/internal installation (LUHFDP).

It includes a 15 foot cable.

NOTE: High frequencies can equate to high

power losses. Always use quality cable. RG58 is

only acceptable on cable runs of up to 5 meters.

We recommend RG213, or equivalent, on

greater lengths. If in doubt consult your dealer.

*Subject to license conditions. Specifically,

mounting height and Effective Radiated Power

(ERP)

.

3.3 IMPORTANT INFORMATION

It is the purchaser's responsibility to deter-

mine the suitability of this equipment and its

derivatives for any given application.

Good working practice dictates that a suit-

able system installation log must be generated,

together with a record of the dates when the

system has been manually checked, (with the

aid of signal strength meters, etc.) enabling the

system performance to be compared with the

original installation data.

3.4 SAFETY INFORMATION

These products are designed to operate safely

when installed and used according to general

safety practices.  The following requirements

should be observed at all times:

Do NOT subject this equipment to:

Mechanical shock

Excessive humidity or moisture

Extremes of temperature

Corrosive liquids

This equipment is designed for indoor use,

unless expressly stated otherwise, and must

not be used in classified Hazardous Areas,

including areas containing explosive or flam-

mable vapors, unless express authorization has

been given in writing by the manufacturer.  If

in doubt, consult Microframe for further infor-

mation.

Do not obstruct any slots or openings in the

product.  These are provided for ventilation to

ensure reliable operation of the product and to

protect it from overheating.

3.5 CARING FOR TRANSMITTER

Only use a damp cloth for cleaning (not

liquid or aerosol-based cleaners), and ensure

that any power is removed from the unit prior

to beginning the cleaning operation.

Removal of covers from the equipment must

only be undertaken by authorized service per-

sonnel, who must ensure that power is isolated

prior to removal.

3.6 LIABILITY

Scope and Microframe do not accept liability

for any damage or injury, caused as the result

of misuse of this equipment. It is the responsi-

bility of the user to ensure that the equipment

is operated in the manner for which it was

intended and that it is the correct item of

equipment for the required task.

3.7 WARRANTY INVALIDATION

Alteration or modification to any part of this

equipment, without the prior written consent

of the manufacturer, will invalidate all manu-

facturer approvals and warranties.  No adjust-

ments can be undertaken except by qualified

and licensed persons as defined by the FCC

Rules and Regulations. Operation of altered

equipment can result in fines, imprisonment,

and/or confiscation of such equipment.

3.8 SERVICE INFORMATION

If you experience a problem with your equip-

ment, please contact Microframe at

1-800-635-3811.

Содержание 3061 Series

Страница 1: ...Microframe Corporation Series 3061 DataTrack Waiter Call Operating Manual B3061 7013 B3061 7013 ...

Страница 2: ...TER INSTALLATION SPECIFICATIONGUIDE ITEM NO A3061 7013 REVISION DATE 08 05 Microframe Corporation 604 S 12th Street Broken Arrow OK 74012 Tel 918 258 4839 Toll Free 1 800 635 3811 Website www microframecorp com E mail support microframecorp com ...

Страница 3: ...amecorp com Safety Do not install substitute parts or perform any modification to the product without first contacting Microframe Warning Allpowertransformers linecords andelec tricalequipmentshouldbekeptoutofthereach of children and away from water Life Support Policy Microframe s products are not autho rized for use as components in life sup port devices or systems without the ex press written a...

Страница 4: ... 9 2 5 TURNING OFF ALL PAGERS 9 3 SYSTEM OVERVIEW 10 3 1 DESCRIPTION 10 3 2 RANGE EXPANSION 10 3 3 IMPORTANTINFORMATION 10 3 4 SAFETY INFORMATION 10 3 5 CARING FOR YOUR TRANSMITTER 10 3 6LIABILITY 10 3 7 WARRANTY INVALIDATION 10 3 8 SERVICE INFORMATION 11 4 POCKET PAGER USER GUIDE 12 4 1 TURNING ON THE PAGER 12 4 2 RECEIVINGAPAGE 12 4 3 MANUAL PAGER TURN OFF 12 4 4 POWER CHECKING 12 4 5 LIGHTING F...

Страница 5: ...tterfeaturesindividualcallbut tonsthatcantransmittoanyof14on sitepagers When a call button is pressed a red light will appear in the cornerofthebuttonpressedtoconfirmapagewassent Available for desktop or wall mounting Operation TheDataTrackOne TouchPagingSystemisdesigned to page wait staff with the simple press of a button Names of servers may be written in the white boxes providedusingwaxpencils ...

Страница 6: ...OCEDURES Ensure that a minimum of 8 inches beneath the intended location is left clear for the an tenna and check that the power cable when fitted is within reach of a wall outlet Using the bracket provided as a template mark out the position of the three holes Check that the bracket is vertical prior to fixing Drill and fix the bracket to the wall using suitable wall plugs and fixing screws Lift ...

Страница 7: ...stem will be affected by the type of material the unit is mounted on and its sur roundings C The following is a list of materials that this transmitter will be adversely affected by if placed in close proximity to a Foil backed wallboard b Metal mesh or wire reinforced glass c Metal sheeting large mirrors or suspended ceilings d Elevator shafts All of the above can reflect radio waves and therebyr...

Страница 8: ...s thelightwillflashforapproximately15seconds before extinguishing automatically This helps to prevent the Server from being repeatedly called unnecessarily When the pager receives the call it will vibrate for a short burst and display the mes sage 1 to indicate a standard call 2 3 THE 2x AND 3x BUTTONS The 2x and 3x keys are programmable for predefinedalphamessagesatthetimeoforder but is limited t...

Страница 9: ...ratesafely when installed and used according to general safety practices The following requirements should be observed at all times Do NOT subject this equipment to Mechanical shock Excessivehumidityormoisture Extremes of temperature Corrosiveliquids This equipment is designed for indoor use unless expressly stated otherwise and must not be used in classified Hazardous Areas including areas contai...

Страница 10: ...ON four times Thewords PGROFF willappearonthe LCD screen Press the LARGE GRAY BUT TON once to confirm NOTE If you have chosen to disable the pagers on off button the pagers can only be turned off from the transmit ter 4 4 POWER CHECKING When the battery level is low a low battery symbol will appear at the bottom of the pager screen 4 5 LIGHTING FUNCTION Pressingthe UPARROWBUTTON forone second can ...

Страница 11: ...owardtheground Avoid mounting the dipole on or near to any metal girders pillars or other metallic obstructions The dipole should preferably be mounted at a height which avoids potential snagging with any moveable objects that might be used in the vicinity i e ladders Ensure that the bracket is firmly bolted to a solid surface and that the feeder cable is adequately clamped along its entire run be...

Страница 12: ...ing for the waiter num ber to be specified The waiter has not made it backtoacknowledgethepage The transmitter takes a little over a second to send a page and then reset The2Xand3Xbuttonsarevery sensitivetotimingandmustbe pressed at exactly the same time CheckthattheDCpoweradapterisconnected tounit Verifythatoutlettransformerisplugged in to has power Call for tech support Press a waiter number or ...

Страница 13: ...poration Series 3061 DataTrack Waiter Call 14 Microframe Corporation 604 S 12th Street Broken Arrow OK 74012 Tel 918 258 4839 Toll Free 1 800 635 3811 Website www microframecorp com E mail support microframecorp com ...

Отзывы: