background image

Microframe Corporation

Series 3007 - DataPage Lite Transmitter

9

3  SYSTEM OVERVIEW

3.1 DESCRIPTION

The Datapage Lite is a desktop transmitter

that can be used to transmit numeric messages

to individual pagers or even an entire group of

pagers.  The system can accommodate up to

9,999 pagers.  The transmitter base identity can

be configured to prevent interference with other

systems.  This transmitter can also transmit an

out-of-range signal.  This allows pagers to indi-

cate when they are no longer within signal

range.

3.2 RANGE EXPANSION

The range and performance of this equip-

ment can be improved by the addition of more

efficient antennas.* These can be installed

either inside or outside the building and are

connected to the transmitter with 50 OHM

coaxial cable.

The center-fed half wave dipole, measuring

approximately 12 inches from tip to tip, will

provide excellent all round local signalling.  It is

a light duty antenna suitable for sheltered

environments/internal installation (LUHFDP).

It includes a 15 foot cable.

NOTE: High frequencies can equate to high

power losses. Always use quality cable. RG58 is

only acceptable on cable runs of up to 5 meters

(16.4 feet.) We recommend RG213, or equiva-

lent, on greater lengths. If in doubt consult your

dealer.

*Subject to license conditions. Specifically,

mounting height and Effective Radiated Power

(ERP)

.

3.3 IMPORTANT INFORMATION

It is the purchaser's responsibility to deter-

mine the suitability of this equipment and its

derivatives for any given application.

Good working practice dictates that a suit-

able system installation log must be generated,

together with a record of the dates when the

system has been manually checked, (with the

aid of signal strength meters, etc.) enabling the

system performance to be compared with the

original installation data.

3.4 SAFETY INFORMATION

These products are designed to operate safely

when installed and used according to general

safety practices.  The following requirements

should be observed at all times:

Do NOT subject this equipment to:

Mechanical shock

Excessive humidity or moisture

Extremes of temperature

Corrosive liquids

This equipment is designed for indoor use,

unless expressly stated otherwise, and must

not be used in classified Hazardous Areas,

including areas containing explosive or flam-

mable vapors, unless express authorization has

been given in writing by the manufacturer.  If

in doubt, consult your local product dealer for

further information.

Do not obstruct any slots or openings in the

product.  These are provided for ventilation to

ensure reliable operation of the product and to

protect it from overheating.

3.5 CARE OF TRANSMITTER

Only use a damp cloth for cleaning (not

liquid or aerosol-based cleaners), and ensure

that any power is removed from the unit prior

to beginning the cleaning operation.

Removal of covers from the equipment must

only be undertaken by authorized service per-

sonnel, who must ensure that power is isolated

prior to removal.

3.6 LIABILITY

Scope and Microframe do not accept liability

for any damage or injury, caused as the result

of misuse of this equipment. It is the responsi-

bility of the user to ensure that the equipment

is operated in the manner for which it was

intended, and that it is the correct item of

equipment for the required task.

3.7 WARRANTY INVALIDATION

Alteration or modification to any part of this

equipment, without the prior written consent

of the manufacturer, will invalidate all manu-

facturer approvals and warranties.  No adjust-

ments can be undertaken except by qualified

and licensed persons as defined by the FCC

Rules and Regulations. Operation of altered

equipment can result in fines, imprisonment,

and/or confiscation of such equipment.

3.8 SERVICE INFORMATION

If you experience a problem with your equip-

ment, please contact Microframe at 1-800-635-

3811.

Содержание 3007 Series

Страница 1: ...Microframe Corporation Series 3007 DataPage Lite Transmitter Operating Manual B3007 7012 B3007 7012 ...

Страница 2: ...INSTALLATION SPECIFICATIONGUIDE ITEM NO A3007 7012 REVISION DATE 07 02 Microframe Corporation 604 S 12th Street Broken Arrow OK 74012 Tel 918 258 4839 Toll Free 1 800 635 3811 Website www microframecorp com E mail support microframecorp com ...

Страница 3: ...nsformers linecords andelec tricalequipmentshouldbekeptoutofthereach of children and away from water Life Support Policy Microframe s products are not autho rized for use as components in life sup port devices or systems without the ex press written approval of the president of Microframe Corporation As used herein 1 Life support devices or systems are de fined as systems which support or sustain ...

Страница 4: ... 2 RANGE EXPANSION 9 3 3 IMPORTANTINFORMATION 9 3 4 SAFETY INFORMATION 9 3 5 CARE OF TRANSMITTER 9 3 6LIABILITY 9 3 7 WARRANTY INVALIDATION 9 3 8 SERVICE INFORMATION 9 5 GEO PULSAR USER GUIDE 10 5 1 TURNING ON THE PAGER 10 5 2 SENDING A PAGE 10 5 3 SENDING AN ALPHA MESSAGE 10 5 4 SENDINGANUMERIC MESSAGE 10 5 5 RECEIVINGAPAGE 10 5 6 SENDING A GROUP CALL PAGE 10 5 7 MANUAL PAGER TURN OFF 10 5 8 PAGE...

Страница 5: ... P O Box 1700 Broken Arrow OK 74013 Features The DataPage Lite Transmitter can send a 12 digit numericmessagecodetoanyof9 999differentpagers Sinceyouownthetransmitter s andreceivers youcan enjoy unlimited paging with no monthly service fee Available for desk mount only Operation The DataPage Lite is a simple plug and play system Once the transmitter is plugged in and batteries are inserted into th...

Страница 6: ...GER 1 9999 The flashing cursor invites you to enter a pagernumber thiscanbeanynumberbetween 1 and 9 999 after which you must press SEND to transmit a page See Operation for further transmittingprocedures IMPORTANT NOTE Use only the power supply included with your system The use of non approved power supplies will invalidate all war ranty and service We also recommend using a surge suppressor for p...

Страница 7: ... call number is 900 unless otherwise specified by the cus tomer 2 3 PAGER TURN OFF FROM BASE Enter the pager number followed by the ENTER key Press ENTER again to bypass Beep Type screen When screen reads Enter Mesage type the code 123456 followed by SEND NOTE The two left parenthesis before the number are required or it will not work 2 4TURNINGOFFALLPAGERS To simultaneously turn all pagers off at...

Страница 8: ...INFORMATION Theseproductsaredesignedtooperatesafely when installed and used according to general safety practices The following requirements should be observed at all times Do NOT subject this equipment to Mechanical shock Excessive humidity or moisture Extremes of temperature Corrosiveliquids This equipment is designed for indoor use unless expressly stated otherwise and must not be used in class...

Страница 9: ... on the pager screen until the pager stops vibrating To view themessageafterthepagerhasstoppedvibrat ing pressthe LARGEBLACKBUTTON once 5 6SENDINGAGROUPCALLPAGE All pagers respond to call number 900 unless another group call number has been chosen To page all pagers at once simply enter 900 and SEND 5 7MANUALPAGERTURN OFF Pressthe RIGHTARROWBUTTON The words PGR OFF will appear on the LCD screen Pr...

Страница 10: ...towardstheground Avoid mounting the dipole on or near to any metal girders pilars or other metallic obstructions The dipole should preferably be mounted at a height which avoids potential snagging with any moveable objects that might be used in the vicinity e g ladders Ensure that the bracket is firmly bolted to a solid suface and that the feeder cable is adequately clamped along it s entire run b...

Страница 11: ...ration Series 3007 DataPage Lite Transmitter 12 Microframe Corporation 604 S 12th Street Broken Arrow OK 74012 Tel 918 258 4839 Toll Free 1 800 635 3811 Website www microframecorp com E mail support microframecorp com ...

Отзывы: