DS1820 digital thermometer is well suited to
environmental temperature measurement,
having the temperature range of -55C to 125C
and the accuracy of +/-0.5C. It must be placed
correctly in the 3-pin socket provided on
EasyPIC4, with its rounded side to the right,
as marked on the board (see Fig. 42) other-
wise the DS1820 could be permanently dam-
aged. DS1820’s data pin can be connected to
either RA5 or RE2 pin, which is determined
by jumper JP11.
JP11
DS1820
VCC
R1
10K
GND
DQ
PICxxxx
RA0
RA1
RA2
RA3
RC0
RC1
RA4
RA5
RE0
RE1
RE2
RC3
RD0
RD1
RC4
RD3
RD2
RC5
RC6
RC7
RD4
RD5
RD6
RD7
RB0
RB1
RB2
RB3
RB4
RB5
RB7
RB6
RC2
VDD
VSS
OSC1
OSC2
MCLR
VDD
VSS
DQ line is
connected to RE2
DQ line is
connected to RA5
DQ line is
connected
dis
-55 C
125 C
VCC
X1
8MHz
C6
22pF
C7
22pF
VCC
VCC
There is a mark in
the form of half-cir-
cle for proper ori-
entation of DS1820
sensor.