AQUADYN® FZ50 Series Hollow Fiber Module | OPERATION MANUAL 

MICRODYN-NADIR | REVISION: B | DATE: 01/08/2020 

4

 

Operation 

To ensure proper operation of AQUADYN

®

 FZ50 hollow fiber modules, please refer to the operating limits specified on the 

product data sheet. 

 

4.1

 

START-UP 

A trial run is recommended prior to actual operation. This eases the membranes into operation and allows purging of any 

remaining air from the system. 
 

At start-up, gradually increase the pressure and flow rate. Then, adjust the flow of the module to approximately 60% of the 
actual operating flow. Allow the system to operate under this condition for at least half a day (approximately 8 hours) or 1 to 

2 days. 
 

TABLE 1. RECOMMENDED START-UP FLOWS & FILTRATION TIMES. 

Filtration Time (intervals between backwashes) 

30 to 90 minutes 

Backwashing Time 

> 50 seconds 

Backwashing Water Volume 

> 200 L 

 

4.1.1

 

Preservative & Air Purge 

1.

 

After start-up, set the permeate flow to 0.5 m

3

/h (2.2 gpm) per module and discharge excess water. This will flush 

out any residual preservative and air from the system. 

2.

 

Be sure to purge the air from the piping and backwash pump. Failure to purge air from the system can result in 

hollow fiber breakages during backwash. 

 

4.2

 

STANDARD OPERATING CONDITIONS 

TABLE 2. STANDARD OPERATION CONDITIONS FOR VARYING FEED WATER TURBIDITIES. 

Type of Feed Water 

Water at Low Turbidity Level (

≤ 

0.5 

NTU) 

Water at Middle Turbidity Level (0.5 to 
5 NTU) 

Water at High Turbidity Level (

 5 NTU) 

Pretreatment 

None 

100-150 µm filter or screen 

100-150 µm filter or screen 

Flow Rate 

a

 

10 m

3

/hr  

(44 gpm) 

3.1 to 5.2 m

3

/hr  

(13.6 to 22.9 gpm) 

 3.1 m

3

/hr  

(

 13.6 gpm) 

Circulation Flow Rate (outlet port) 

0 to 7.4 m

3

/hr 

(0 to 32.6 gpm) 

3.7 to 7.4 m

3

/hr 

(16.3 to 32.6 gpm) 

7.4 m

3

/hr 

(32.6 gpm) 

Backwash Flow Rate 

b

 

15 m

3

/hr (66 gpm) 

15 m

3

/hr (66 gpm) 

15 m

3

/hr (66 gpm) 

NaClO Concentration in Backwash 
Water 

3 to 5 mg/L 

3 to 5 mg/L 

3 to 5 mg/L 

Water Temperature 

 35°C (95°F) 

c

 

 35°C (95°F) 

c

 

 35°C (95°F) 

c

 

pH Range 

4 to 8 

4 to 8 

4 to 8 

Chemical Cleaning 

1)

 

Periodical cleaning 

2)

 

Implemented when the 

transmembrane pressure increases 
to 0.07 MPa (10.2 psi) 

d

 

1)

 

Periodical cleaning 

2)

 

Implemented when the 
transmembrane pressure 
increases to 0.07 MPa (10.2 psi) 

d

 

1)

 

Periodical cleaning 

2)

 

Implemented when the 
transmembrane pressure increases 
to 0.07 MPa (10.2 psi) 

d

 

a

 Value based on 20°C (68°F) water temperature. 

b

 To be set according to the recovery ratio. 

c

 While the data sheet lists a maximum temperature of 40°C, this is for short time periods only. The maximum recommended 

temperature for long periods of operation is 35°C. 

d

 The supply pressure at the general start of operation is approximately 0.01 to 0.03 MPa.  

Note:

 The values above are the standard conditions and they vary depending on the quality of feed water. 

 

4.3

 

OPERATION 

The operating flux largely depends on the quality of the feed water and is usually determined based on test or pilot results. 

Pilot tests typically last about 6 months and include periods at various temperatures. The feed flow rate, just like the flux, is 
based on the feed water quality. For standard filtration, set the recovery ratio to 90%. The valves switch and the pump 

starts and stops automatically in the following order during operation: 
 

1.

 

Filtration for 45 minutes 

2.

 

30-second backwashing is implemented twice 

Содержание AQUADYN FZ50 Hollow

Страница 1: ...AQUADYN FZ50 Hollow Fiber Module Operation Manual...

Страница 2: ...IR REVISION B DATE 01 08 2020 2 Contact Europe Germany 49 611 962 6001 Italy 39 0721 1796201 info microdyn nadir com Americas USA 1 805 964 8003 Brazil 55 11 3378 7500 info microdyn nadir com Asia Chi...

Страница 3: ...P FLOWS FILTRATION TIMES 8 4 1 1 Preservative Air Purge 8 4 2 STANDARD OPERATING CONDITIONS 8 TABLE 2 STANDARD OPERATION CONDITIONS FOR VARYING FEED WATER TURBIDITIES 8 4 3 OPERATION 8 4 3 1 Feed pH 9...

Страница 4: ...ions of Chemical Cleaning 12 7 2 CLEANING PROCEDURE 12 TABLE 4 STANDARD CHEMICAL CLEANING PROCEDURE OF AQUADYN FZ50 MODULES 13 7 2 1 Cleaning Steps 15 7 2 2 Measuring the Flux 17 TABLE 5 WATER TEMPERA...

Страница 5: ...llution Due to the optimized design efficient flow distribution cleaning minimal pressure drop and high packing density can be achieved Moreover the AQUADYN FT50 CTA materials are superior in their hy...

Страница 6: ...hat contains ester plasticizer or e g flexible polyvinyl chloride tube etc Avoid exposing the FZ50 modules to organic solvents cleaning substances fat oil or adhesive tape as these materials may cause...

Страница 7: ...the module The plug inserted in the lower port is not pressure proof be sure to remove this plug before operation 3 Position the module vertically to discharge excess preservative If preservative sol...

Страница 8: ...10 m3 hr 44 gpm 3 1 to 5 2 m3 hr 13 6 to 22 9 gpm 3 1 m3 hr 13 6 gpm Circulation Flow Rate outlet port 0 to 7 4 m3 hr 0 to 32 6 gpm 3 7 to 7 4 m3 hr 16 3 to 32 6 gpm 7 4 m3 hr 32 6 gpm Backwash Flow...

Страница 9: ...for a given feed water the transmembrane pressure will increase in a short period of time 4 3 5 Flow Rate Set the flow so that the liquid linear velocity along the membrane surface on the outlet port...

Страница 10: ...double the TMP during filtration However the maximum backwashing pressure TMP should be 0 2 MPa or less If the backwash pressure exceeds this limit a chemical cleaning is recommended to help further r...

Страница 11: ...SHORT TERM STORAGE 2 DAYS OR LESS Backwash the module immediately before stopping operation The backwash water free chlorine concentration of 3 5 mg L needs to remain in the module Be sure that liquid...

Страница 12: ...fat Depending on acidic property and chelate effect Proteolytic enzyme contained Sodium hypochlorite NaClO Sodium hypochlorite NaClO Effective chlorine concentration 50 ppm Low solubility organic sub...

Страница 13: ...ning 1 wt 0 1 2 35 5 Mixed chemical solution soak 1 wt 120 35 6 Mixed chemical solution 2 port counter pressure cleaning 1 wt 0 1 2 35 Max 14 5 7 Mixed chemical solution flushing cleaning 1 wt 20 35 1...

Страница 14: ...ure cleaning 2 Measurement of flux Cleaning with mixed chemical solution 3 Measurement of flux Cleaning with sodium hypochlorite water solution 4 Measurement of flux 2 90 of operating flux 3 90 of ope...

Страница 15: ...2 Water backwash a Feed the water into the permeate port at the top of the module at up to 0 1 Mpa for approximately one minute approximately 300 L or 80 gal and discharge it from the inlet feed wate...

Страница 16: ...or a predefined time e After the soak is complete carry out the backwash using the chemical solution 5 Flush cleaning using chemical solution a Prepare the chemical solution using the recommended conc...

Страница 17: ...igure 4 Flux Measurement Conditions Feed water ulltrafiltered pure water Filtration mode dead end filtration by fully closing the feed water outlet port Inlet pressure approximately 0 05 MPa Measureme...

Страница 18: ...915 0 913 0 911 0 909 0 907 0 905 0 903 0 901 0 899 0 898 31 0 896 0 894 0 920 0 890 0 888 0 886 0 884 0 882 0 881 0 879 32 0 877 0 875 0 873 0 871 0 870 0 868 0 866 0 864 0 862 0 861 33 0 859 0 857 0...

Страница 19: ...emaining contaminants After filling the module with the preservative solution please check the free chlorine concentration If there s a chance that the preservative may freeze during storage or transp...

Страница 20: ...ION B DATE 01 08 2020 20 9 Disposal of the Module Always follow proper disposal processes when discharging wastewater or preservative solution or when disposing a UF module If hazardous substances rem...

Страница 21: ...AQUADYN FZ50 Series Hollow Fiber Module OPERATION MANUAL MICRODYN NADIR REVISION B DATE 01 08 2020 21 10 Appendix 10 1 DIMENSIONS OF AQUADYN FZ50 AC FUC1582 MODULE...

Страница 22: ...ION MANUAL MICRODYN NADIR REVISION B DATE 01 08 2020 22 10 2 CUT OFF CURVE FOR AQUADYN FZ50 AC FUC1582 MODULE Fig 2 Cut Off Curve of FUC1582 0 10 20 30 40 50 60 70 80 90 100 1 10 100 Molecular Weight...

Страница 23: ...8 2020 23 10 3 TRANSMEMBRANE PRESSURE VS PERMEATE RATE Transmembrane Pressure Feed Pressure Concentrate Pressure 2 Permeate Pressure Module AQUADYN FZ50 AC FUC1582 Feed Pure Water Conditions Dead End...

Страница 24: ...VISION B DATE 01 08 2020 24 10 4 FEED PRESSURE VS PERMEATION RATE Feed Pressure Inlet Pressure at Lower Feed Port Module AQUADYN FZ50 AC FUC1582 Feed Pure Water Conditions Dead End Filtration 100 Reco...

Страница 25: ...W VS MODULE PRESSURE DROP Module Pressure Drop Feed Pressure at Lower Feed Port Feed Pressure at Upper Feed Port Module AQUADYN FZ50 AC FUC1582 Feed Water Pure Water Water Temperature 21 3 C Condition...

Отзывы: