TIME CLOCK
The internal time clock needs to be set to the correct local time.
9.1.1 SETTING DATE & TIME
1. Press and hold F4 for three seconds.
2. Display screen will change to day, time and date.
3. Press “ESC” once.
4. Display screen will indicate “Stop”, “Program”, “Setup”, “Diagnostics” and “Network” with “>” indicating
selection.
5.
Use the ▲&▼buttons to move the
>selection indicator to “>Setup” and press OK.
6.
Use the ▲&▼buttons to move the >
selection indicator to “>Clock.” and press OK.
7.
Use the ► & ◄ buttons to move the cursor and the ▲&▼buttons to c
hange the value.
8. Once the value is changed move the cursor to the next value.
9. Set the date and time and press OK to save.
10. Press “ESC” to exit the current menu.
11. To exit the menus completely, press the “ESC” until day, time and date is displayed and press th
e ▲button.
12. The display will return to the home screen
9.1.2 SETTING AUXILIARY PARAMETERS
1. Auxiliary features only operate in “Auto” (F2)
2. The RHINO pump system has internal features that can be activated if required. The features consist of a
drain valve timer, three, 24 hour, 7 day clock timers, cycle/pulse timer, temperature and humidity control
(optional upgrade)
3. To access and activate these features follow the steps bellow:
4. Press and hold F4 for three seconds.
5. Display screen will change to day, time and date.
6. Press “ESC” once.
7. Display screen will indicate “Stop”, “Set Param”, Msg Config” and “Set..” with “>” indicating selection.
8.
Use the ▲&▼buttons to move the >selection i
ndicator to “>Set Program” and press OK.
9.
Use the ▲&▼buttons to move the >selection indicator to “>Set Param
eters” and press OK.
10.
Using the ▲&▼buttons
to move through the menu until you get to required option and press OK.
11.
Use the ► & ◄ buttons to move the cursor and the ▲&▼buttons to change the value.
12. Once the value is changed move the cursor to the next value.
13. To save the changes press the “OK” button once.
DRAIN/PRESSURE RELIEF VALVE TIME
The drain/pressure relief valve time is the time setting that determines how long the drain valve remains open after
pump unit shuts down. This valve can be used to only relive the nozzle line pressure or relieve the nozzle line
pressure and drain the system. If only pressure relief is required then a short time of 10 – 15 seconds is adequate, if
the system is required to drain completely then a longer time setting would be required, depending on the system
size and length of manifold lines.
9.2.1 SETTING DRAIN VALVE TIME
1. The following feature is available in “Set Param” and is labeled as “DRAIN T” the default drain time
setting is 30 seconds.
2. To access and increase or decrease the drain time, follow the steps in 9.2 "Setting Auxiliary
Parameters”
24 HOUR, 7 DAY CLOCK TIME
The controller contains three 24 hour 7 day time clocks that can be set to start and stop the pump unit on pre-set
days and times as required. Special care should be taken so as not to not program conflicting times.
Содержание RHINO 15
Страница 27: ...Master Rhino Manual_March 2020 docx March 20 Page 27 of 38 14 RHINO ILLUSTRATIONS RHINO FRONT VIEW...
Страница 28: ...Master Rhino Manual_March 2020 docx March 20 Page 28 of 38 RHINO BACK VIEW...
Страница 29: ...Master Rhino Manual_March 2020 docx March 20 Page 29 of 38 RHINO RIGHT SIDE VIEW...
Страница 30: ...Master Rhino Manual_March 2020 docx March 20 Page 30 of 38 RHINO LEFT SIDE VIEW...
Страница 31: ...Master Rhino Manual_March 2020 docx March 20 Page 31 of 38 RHINO PLAN VIEW...
Страница 32: ...Master Rhino Manual_March 2020 docx March 20 Page 32 of 38 RHINO FILTER AND BRACKET...
Страница 33: ...Master Rhino Manual_March 2020 docx March 20 Page 33 of 38 CONTROL PANEL 1...
Страница 34: ...Master Rhino Manual_March 2020 docx March 20 Page 34 of 38 CONTROL PANEL 2...
Страница 35: ...Master Rhino Manual_March 2020 docx March 20 Page 35 of 38 CONTROL PANEL 3...
Страница 36: ...Master Rhino Manual_March 2020 docx March 20 Page 36 of 38 CONTROL PANEL 4...
Страница 37: ...Master Rhino Manual_March 2020 docx March 20 Page 37 of 38 RHINO SOLENOID...
Страница 38: ...Master Rhino Manual_March 2020 docx March 20 Page 38 of 38 RHINO NOTES...