IBEX 8 Nozzle
SMALL FRAME_June 2020
June 20 Page 5 of 41
WARNING!!
PLEASE TAKE NOTE OF THE FOLLOWING
1.
BEFORE STARTING
PLEASE READ THIS GUIDE ENTIRELY BEFORE BEGINNING INSTALLATION
ALSO, READ SUPPLEMENTAL INFORMATION RELATING TO OPTIONAL CONTROL EQUIPMENT
CRANKCASE OIL PLUG
The pump module crankcase vent has been plugged to prevent accidental oil leakage during shipment. Remove
the plug and replace with the supplied vent cap before operating pump unit. Failure to do so will cause oil leaks.
OIL LEVEL
Check that the oil level appears 1/2 way in the sight gauge or within range on the dipstick in the pump head.
INLET WATER SUPPLY PRESSURE.
When the pump module is running, it must be supplied with an inlet water supply of
NEVER
LESS
THAN
20
P.S.I.
(1.40
BAR)
AND
NEVER
MORE
THAN
90
P.S.I.
(6.20
BAR)
•
I
NLET WATER SUPPLY PRESSURE SHOULD BE STEADY AND SHOULD NOT BE ALLOWED TO FLUCTUATE OUTSIDE OF THESE
RANGES
.
F
AILURE TO DO SO CAN RESULT IN DAMAGE TO EQUIPMENT AND IS NOT COVERED BY WARRANTY
.
•
IF
WATER
PRESSURE
DROPS
BELOW
20
PSI,
THE
PUMP
WILL
SHUT
OFF
AND
THE
FAULT
LIGHT
WILL
COME
ON.
SEE
SECTION
9
SYSTEM
OPERATION
FOR
FUTHER
INFORMATION.
OIL CHANGE INTERVAL
The crankcase oil must be changed after the first
50 hours
of operation and from then on, once every 500 hours.
•
SYNTHETIC
75
W
-90
GEAR OIL IS RECOMMENDED FOR ALL APPLICATIONS
(
MOBILE ONE OR EQUAL
)
•
S
ECONDARY CHOICE SYNTHETIC
15
W
-50
MOTOR OIL MAY BE USED FOR ALL APPLICATIONS
(
MOBILE ONE OR EQUAL
)
HIGH PRESSURE FITTINGS
The system operates at 1,000 P.S.I. (70 bar) and should always be shut down when working on fittings or manifold
line. Extreme caution should always be exercised when working with high pressure water. Always wear safety glass
when working around fog equipment.
INLET WATER SUPPLY PLUMBING MATERIAL
Only rated and approved brass fittings or stainless steel fittings should be used to make plumbing connections. The
use of
galvanized or steel pipe fittings
can cause system failure, nozzle blockage and pump damage.
FLUSHING THE SYSTEM
Before pressurizing the system, flush all plumbing and atomization lines thoroughly to purge any residual debris.
Please refer to the startup section 7 of this manual.
TEFLON TAPE
When using Teflon tape on NPT threads, leave 1 or 2 of the starting threads showing. This will prevent pieces of
Teflon tape from entering the system, which could cause blockage or damage.
Содержание IBEX 1000
Страница 31: ...IBEX 8 Nozzle SMALL FRAME_June 2020 June 20 Page 31 of 41 IBEX 1 3 GALLON REAR VIEW...
Страница 32: ...IBEX 8 Nozzle SMALL FRAME_June 2020 June 20 Page 32 of 41 IBEX 1 3 GALLON RIGHT SIDE VIEW...
Страница 33: ...IBEX 8 Nozzle SMALL FRAME_June 2020 June 20 Page 33 of 41 IBEX 1 3 GALLON LEFT SIDE VIEW...
Страница 34: ...IBEX 8 Nozzle SMALL FRAME_June 2020 June 20 Page 34 of 41 IBEX 1 3 GALLON TOP VIEW...
Страница 35: ...IBEX 8 Nozzle SMALL FRAME_June 2020 June 20 Page 35 of 41 IBEX 1 3 GALLON INTERNAL TOP VIEW...
Страница 36: ...IBEX 8 Nozzle SMALL FRAME_June 2020 June 20 Page 36 of 41 IBEX 1 3 GALLON BOTTOM VIEW...
Страница 37: ...IBEX 8 Nozzle SMALL FRAME_June 2020 June 20 Page 37 of 41 IBEX 1 3 GALLON 240V CONTROL PANEL...
Страница 38: ...IBEX 8 Nozzle SMALL FRAME_June 2020 June 20 Page 38 of 41 IBEX 1 3 GALLON 480V CONTROL PANEL...
Страница 39: ...IBEX 8 Nozzle SMALL FRAME_June 2020 June 20 Page 39 of 41 IBEX 1 3 GALLON NOTES 1...
Страница 40: ...IBEX 8 Nozzle SMALL FRAME_June 2020 June 20 Page 40 of 41 IBEX 1 3 GALLON NOTES 2...
Страница 41: ...IBEX 8 Nozzle SMALL FRAME_June 2020 June 20 Page 41 of 41 IBEX 1 3 GALLON 208 240V ELECTRICAL DIAGRAM...