background image

IBEX 8 Nozzle

 SMALL FRAME_June 2020

     June 20 Page 28 of 41 

12. 

WARRANTY 

 

 

Products manufactured by MicroCool

 bear the following limited warranty: 

 

MicroCool warrants that the goods to be delivered will be of the kind and quality described in the sales order or 

contract, and will be free of defects in workmanship or material. Should any failure to conform to this warranty 

appear within the time limit stated below, after the initial date of delivery, the MicroCool shall, upon notification 

thereof, and written substantiation that the goods have been stored, installed, maintained and operated in 

accordance with the seller's recommendations and standard industry practice, correct such defect by suitable repair 

or replacement at its own expense. This warranty is limited to repairing or replacing products that the 

manufacturer's investigation shows were defective at the time of shipment by the manufacturer. An RMA number 

must be obtained from MicroCool

 before returning a product for warranty consideration or repair.   

 

Warranty period: 

 

One (1) year on all MicroCool manufactured goods

 

 

 

 

 

Two (2) years on coupled Weg motor and VF Drive 

 

 

 

 

The lesser of One (1) year or 4,000 hours use on pump head 

 

Notification Period:  

 

Notify MicroCool within 15 days of determining defect. 

Product Return Period:  Return defect product within 30 days to MicroCool 

All products subject to this warranty shall be returned for examination, repair or replacement, freight pre-paid to: 

 

MicroCool

 

 

72216 Northshore Street #103-104 

 

 

 

 

Phone#  

760-322-1111 

Thousand Palms, California  92276, USA  

 

 

 

FAX#      

760-343-1820 

 

E-mail address: 

[email protected]

 

  

 

 

 

Web site: www.microcool.com  

 

This warranty is exclusive and is in lieu of any warranty or merchantability, fitness for a particular purpose or other 

warranty of quality, whether express or implied, except of title and against patent infringement. Correction of non-

conformities, in the manner and for the period of time provided above, shall constitute fulfillment of all liabilities of 

the seller to the purchaser with respect to, or arising out of the goods, whether based on contract negligence, strict 

tort or otherwise. 

 

LIMITATION OF LIABILITY - Repair or replacement of defective products as provided above is the sole and 

exclusive remedy provided hereunder and the seller shall not under any circumstances be liable for special or con-

sequential damages such as, but not limited to, damage or loss of other property or equipment, loss of profits, or 

revenue, cost of capital, cost of purchased or replacement goods, or claims or customers of purchaser for service 

interruptions. The remedies of the purchaser set forth are exclusive and the liability of seller with respect to any 

contract, or anything done in connection therewith such as the performance or breach thereof, or from the 

manufacture, sale, delivery, resale, installation or use of any goods covered by or furnished under this contract 

whether arising out of contract, negligence, strict tort, or under any warranty, or otherwise, shall not, except as 

expressly provided herein, exceed the price of the goods upon which such liabilities based. This is the only warranty 

on any MicroCool

 product; no other writing or description in the literature shall be construed as a warranty. 

Products manufactured by other than MicroCool

 bear the following limited warranty: 

 

Seller warrants that the goods manufactured by others will conform to the description herein stated. No other 

warranty express or implied is made, and the warranty of the manufacturer is hereby assigned and transferred to 

the buyer. Furthermore, except for the manufacturer's warranty, if any, the products sold hereunder are sold as is. 

MicroCool

 is not liable for any incidental or consequential damages in connection with these products. 

 

In addition to all of the above, MicroCool

 accepts no liability if the system is used to dispense corrosive, toxic or 

other non-approved agents. MicroCool

 will not be responsible for poor water quality damage or nozzle blockage 

due to poor water quality. 

 

 

MicroCool

  

 

 

Содержание IBEX 1000

Страница 1: ...une 20 Page 1 of 41 IBEX SERIES 1 3 GPM 2020 Installation Maintenance Manual Version 06 20 MicroCool 72216 Northshore Street 103 104 Thousand Palms CA 92276 USA www microcool com Phone 1 760 322 1111...

Страница 2: ...OLET WATER PURIFIERS 6 REVERSE OSMOSIS WATER TREATMENT 6 3 INSTALLATION OF THE PUMP MODULE 7 POSITIONING THE PUMP MODULE 7 WATER SUPPLY AND CONNECTION 7 DRAINAGE FROM THE PUMP 7 4 PUMP MODULE POWER SU...

Страница 3: ...Setting for Humidity control with Temperature override 15 Setting for Temperature control with Humidity override 15 To view the VFD fault code 15 10 SYSTEM MAINTENANCE 22 CRANKCASE OIL 22 SYNTHETIC 7...

Страница 4: ...IEW 32 IBEX 1 3 GALLON LEFT SIDE VIEW 33 IBEX 1 3 GALLON TOP VIEW 34 IBEX 1 3 GALLON INTERNAL TOP VIEW 35 IBEX 1 3 GALLON BOTTOM VIEW 36 IBEX 1 3 GALLON 240V CONTROL PANEL 37 IBEX 1 3 GALLON 480V CONT...

Страница 5: ...SEE SECTION 9 SYSTEM OPERATION FOR FUTHER INFORMATION OIL CHANGE INTERVAL The crankcase oil must be changed after the first 50 hours of operation and from then on once every 500 hours SYNTHETIC 75W 9...

Страница 6: ...ation WATER TREATMENT Generally speaking most municipal water is suitable for atomization Well water river water and the like should be tested before atomizing If an analysis indicates any unusually h...

Страница 7: ...wn in the table below Pump Model Flow MIN Flow rate USGPM MIN Flow Rate LPM MIN Pressure psi bars IBEX 1000 1 00gpm 1 00 3 79 20 1 40 IBEX 2000 2 00gpm 3 00 11 40 20 1 40 IBEX 3000 2 50gpm 3 75 14 25...

Страница 8: ...irectly to a fused disconnect box If the power supply cannot be directly wired to a disconnect box then it should be hard wired using a junction box into a suitable circuit with a disconnect box locat...

Страница 9: ...te care must be taken NOT to connect a different or separate power supply to these terminals as serious damage could occur If in doubt please contact the factory for a suitable relay or conditioner WA...

Страница 10: ...ter pressure is not sufficient do not try to start the pump The water pressure problem must be corrected first 7 1 4 To prime the pump module turn on the power supply to the IBEX module open the elect...

Страница 11: ...ump 2 Turn off the electrical supply at the disconnect switch to electrically isolate the pump 3 Locate the pressure transducer and unplug the electrical lead by squeezing the clip 4 Restore the power...

Страница 12: ...wired input switch into the electrical control panel on terminal 1 2 on TB1 yellow and blue terminal blocks Auto mode is also used if the internal 24 hour 7 day clocks and or internal temperature and...

Страница 13: ...steps bellow 4 Press and hold F4 for three seconds 5 Display screen will change to day time and date 6 Press ESC once 7 Display screen will indicate Stop Set Param Msg Config and Set with indicating s...

Страница 14: ...presents on time and TL represents the off time Setting Cycle Pulse Timer 1 The following feature is available in Set Param and is labeled as CYCLE T the default setting is 1 minute on and 1 minute of...

Страница 15: ...p contact 2 Set the humidity set point to desired humidity to be maintained as described above 3 The controller will start the pump system when the humidity drops below the set point Setting for Tempe...

Страница 16: ...ver turn the black screw release counter clockwise about 1 8 and hold it in that position 3 Pull the door open with the red disconnect switch in the vertical position 4 Once the inspection is complete...

Страница 17: ...set F4 Hold for 3 seconds to enter parameter settings Data Plate Press and hold F4 for 3 seconds The pump detail display will remain visible for 30 seconds Model number Serial number Manufacture date...

Страница 18: ...ve when temp and humid soft key is set to ON in parameter set only available with optional upgrade Auto Run Control Parameters Pump is running in AUTO System pressure Current humidity Current temperat...

Страница 19: ...9 of 41 Pressure Relief Pump has stopped and is draining System pressure Drain Time Auto Cycle Run Pump is running on cycle time On timer System pressure Hours of Operation Auto Start Delay Auto Start...

Страница 20: ...the system locks out on a fault Frequency Inverter Fault Pump system has faulted on VFD fault 30 second restart delay is in process If VFD fault is cleared within 30 seconds pump will restart and oper...

Страница 21: ...ctly and are in Auto Press F3 to reset if fault does not clear activate the prime and flush sequence by pressing F3 and F4 simultaneously This will flush the pump system with cool supply water Once it...

Страница 22: ...and some require lubrication periodically Refer to the motor nameplate for the type of motor If the motor is equipped with external grease nipples refer to the chart below for lubrication instructions...

Страница 23: ...ter cartridges with new dry cartridges Turn off electrical power to pump module This will help to prevent water freezing and damaging the pump or its components Note The pump unit has an automatic flu...

Страница 24: ...ation of the bulb and receptacle and gently plug the new bulb into the receptacle ensuring that it goes in all the way 4 Replace the receptacle onto the UV housing and reinstall the locking pin 5 The...

Страница 25: ...en restored or VFD was able to automatically re set the fault will clear and system will return to normal operation If the fault s has not been cleared the pump system will lock out and the LCD Displa...

Страница 26: ...wer supply and parameter P0296 Supply voltage is too high producing voltage on the DC link above the maximum value in P0004 Ud 410 Vdc in 200 240 Vac P0296 0 Ud 810 Vdc in 380 480 Vac P0296 1 Ud 1000...

Страница 27: ...or cable capacitance too high causing current peaks in the output F0076 This fault indicates the motor presents phase loss imbalanced phase current or is disconnected Motor wiring or connection error...

Страница 28: ...of time provided above shall constitute fulfillment of all liabilities of the seller to the purchaser with respect to or arising out of the goods whether based on contract negligence strict tort or ot...

Страница 29: ...ould be considered as being covered by UL s Certification and Follow Up Service Look for the UL Certification Mark on the product CERTIFICATE OF COMPLIANCE Certificate Number 20190307 E352513 Report R...

Страница 30: ...IBEX 8 Nozzle SMALL FRAME_June 2020 June 20 Page 30 of 41 14 IBEX 1 3 Gallon Illustrations IBEX 1 3 GALLON FRONT VIEW...

Страница 31: ...IBEX 8 Nozzle SMALL FRAME_June 2020 June 20 Page 31 of 41 IBEX 1 3 GALLON REAR VIEW...

Страница 32: ...IBEX 8 Nozzle SMALL FRAME_June 2020 June 20 Page 32 of 41 IBEX 1 3 GALLON RIGHT SIDE VIEW...

Страница 33: ...IBEX 8 Nozzle SMALL FRAME_June 2020 June 20 Page 33 of 41 IBEX 1 3 GALLON LEFT SIDE VIEW...

Страница 34: ...IBEX 8 Nozzle SMALL FRAME_June 2020 June 20 Page 34 of 41 IBEX 1 3 GALLON TOP VIEW...

Страница 35: ...IBEX 8 Nozzle SMALL FRAME_June 2020 June 20 Page 35 of 41 IBEX 1 3 GALLON INTERNAL TOP VIEW...

Страница 36: ...IBEX 8 Nozzle SMALL FRAME_June 2020 June 20 Page 36 of 41 IBEX 1 3 GALLON BOTTOM VIEW...

Страница 37: ...IBEX 8 Nozzle SMALL FRAME_June 2020 June 20 Page 37 of 41 IBEX 1 3 GALLON 240V CONTROL PANEL...

Страница 38: ...IBEX 8 Nozzle SMALL FRAME_June 2020 June 20 Page 38 of 41 IBEX 1 3 GALLON 480V CONTROL PANEL...

Страница 39: ...IBEX 8 Nozzle SMALL FRAME_June 2020 June 20 Page 39 of 41 IBEX 1 3 GALLON NOTES 1...

Страница 40: ...IBEX 8 Nozzle SMALL FRAME_June 2020 June 20 Page 40 of 41 IBEX 1 3 GALLON NOTES 2...

Страница 41: ...IBEX 8 Nozzle SMALL FRAME_June 2020 June 20 Page 41 of 41 IBEX 1 3 GALLON 208 240V ELECTRICAL DIAGRAM...

Отзывы: