Time Clock
The internal time clock needs to be set to the correct local time.
Setting Date & Time
1. Press and hold F4 for three seconds.
2. Display screen will change to day, time and date.
3. Press “ESC” once.
4. Display screen will indicate “Stop”, “Program”, “Setup”, “Diagnostics” and “Network” with “>” indicating
selection.
5.
Use the ▲&▼buttons to move the
>selection indicator to “>Setup” and press OK.
6.
Use the ▲&▼buttons to move the >
selection indicator to “>Clock.” and press OK.
7.
Use the ► & ◄ buttons to move the cursor and the ▲&▼buttons to change the value.
8. Once the value is changed move the cursor to the next value.
9. Set the date and time and press OK to save.
10. Press “ESC” to exit the current menu.
11.
To exit the menus completely, press the “ESC” until day, time and date is displayed and press the ▲button.
12. The display will return to the home screen
Setting Auxiliary Parameters
1. Auxiliary features only operate in “Auto” (F2)
2. The Ibex pump system has internal features that can be activated if required. The features consist of a
drain valve timer, three, 24 hour, 7 day clock timers, cycle/pulse timer, temperature and humidity control
(optional upgrade)
3. To access and activate these features follow the steps bellow:
4. Press and hold F4 for three seconds.
5. Display screen will change to day, time and date.
6. Press “ESC” once.
7. Display screen will indicate “Stop”, “Set Param”, Msg Config” and “Set..” with “>” indicating selection.
8.
Use the ▲&▼buttons to move the >selection indicator to “>Set
Program” and press OK.
9.
Use the ▲&▼buttons to move the >selection indicator to “>Set Param
eters” and press OK.
10.
Using the ▲&▼bu
ttons to move through the menu until you get to required option and press OK.
11.
Use the ► & ◄ buttons to move the cursor and the ▲&▼buttons to change the value.
12. Once the value is changed move the cursor to the next value.
13. To save the changes press the “OK” button once.
Drain/Pressure Relief Valve Time
The drain/pressure relief valve time is the time setting that determines how long the drain valve remains open after
pump unit shuts down. This valve can be used to only relive the nozzle line pressure or relieve the nozzle line
pressure and drain the system. If only pressure relief is required then a short time of 10 – 15 seconds is adequate, if
the system is required to drain completely then a longer time setting would be required, depending on the system
size and length of manifold lines.
Setting Drain Valve Time
1. The following feature is available in “Set Param” and is labeled as “DRAIN T” the default drain time
setting is 30 seconds.
2. To access and increase or decrease the drain time, follow the steps in 9.2 "Setting Auxiliary
Parameters”
Содержание IBEX 1000
Страница 31: ...IBEX 8 Nozzle SMALL FRAME_June 2020 June 20 Page 31 of 41 IBEX 1 3 GALLON REAR VIEW...
Страница 32: ...IBEX 8 Nozzle SMALL FRAME_June 2020 June 20 Page 32 of 41 IBEX 1 3 GALLON RIGHT SIDE VIEW...
Страница 33: ...IBEX 8 Nozzle SMALL FRAME_June 2020 June 20 Page 33 of 41 IBEX 1 3 GALLON LEFT SIDE VIEW...
Страница 34: ...IBEX 8 Nozzle SMALL FRAME_June 2020 June 20 Page 34 of 41 IBEX 1 3 GALLON TOP VIEW...
Страница 35: ...IBEX 8 Nozzle SMALL FRAME_June 2020 June 20 Page 35 of 41 IBEX 1 3 GALLON INTERNAL TOP VIEW...
Страница 36: ...IBEX 8 Nozzle SMALL FRAME_June 2020 June 20 Page 36 of 41 IBEX 1 3 GALLON BOTTOM VIEW...
Страница 37: ...IBEX 8 Nozzle SMALL FRAME_June 2020 June 20 Page 37 of 41 IBEX 1 3 GALLON 240V CONTROL PANEL...
Страница 38: ...IBEX 8 Nozzle SMALL FRAME_June 2020 June 20 Page 38 of 41 IBEX 1 3 GALLON 480V CONTROL PANEL...
Страница 39: ...IBEX 8 Nozzle SMALL FRAME_June 2020 June 20 Page 39 of 41 IBEX 1 3 GALLON NOTES 1...
Страница 40: ...IBEX 8 Nozzle SMALL FRAME_June 2020 June 20 Page 40 of 41 IBEX 1 3 GALLON NOTES 2...
Страница 41: ...IBEX 8 Nozzle SMALL FRAME_June 2020 June 20 Page 41 of 41 IBEX 1 3 GALLON 208 240V ELECTRICAL DIAGRAM...