4. Miner Connection and Pre-Power Check
(
1
)
Before the wiring and power-on of the machine, according to the warning signs
on the side of the machine, shake the machine to check whether there is a radiator or
other components loose. This is to ensure that there is no radiator or other components
that may fall off before wiring and power-on.
(
2
)
The machine is connected to the power wiring, and the network port is
connected to the switch. Check the power control wiring, fan control wiring, adapter
board control wiring, and ensure that the fan control wiring is not loose, and the copper
line is connected correctly before powering on the machine.
Notes
:
(
1
)
When the power copper busbar is connected to the hash board, the positive and
negative poles of the copper busbar are connected correctly, and the screw washers of
the fixed copper bar are aligned parallel to the edge of the copper bar, the fixed screws
must be tightened. Otherwise the power board may burn out. For the control board
and power supply, hardware damage caused by copper stripping is not covered by the
warranty.
(
2
)
The power control wiring between the control board and the power supply must
be connected. Otherwise, the power supply voltage output may not be controlled,
resulting in low power calculation.
(
3
)
The control board must be connected to the fan wiring securely. If the fan wiring
is disconnected or the connection is poor, the miner may not be able to cool down, the
power board throttled, and the power reduced.
5. Miner Data Configuration
(
Configuration on
the web page
)
5.1. Query the dynamic IP address obtained by the miner
5.1.1. Run WhatsMinerTools software
Miner Data Configuration: Connect PC to the same network the machine is located, run
WhatsMinerTools
software on the PC, select the “Detect IP” tab, set the room number,
rack number and layer number of the rack where the mining machine is located, the
location number of the layer, click "Start".