
ROWS
SECTION
METER
CAL
ROW
SPACING
ADJUST
RATE
TARGET
RATE
SPEED
CAL
METER CAL
TEST
TEST
SPEED
RPM
(1) (2) (3)
DISTANCE
AREA /
HOUR
SEEDS
(1) (2) (3)
SEEDS /
DISTANCE
SPEED
AREA
(1) (2) (3)
ON
OFF
L
C
R
SECTIONS
RUN
HOLD
CAL
AUTO
MAN
RESET
ON / OFF
____
SEED RATE
SEED
SPACING
RATE 1
RATE 2
RATE 3
AUTO
Operation
(cont)
Resetting System Counters
The AREA, DISTANCE and SEED counters maintain a running
count during operation regardless of the position of the
rotary switch. When any of these counters reach their
maximum capacity, or when you want to start a new count,
the value may be reset to zero by performing the following
routine. Counter pairs may be reset independently of other
counter pairs.
1. Turn the sections OFF or put the system in HOLD.
2. Turn the rotary switch to the counter to be reset.
3. To reset distance turn the rotary switch to DISTANCE and
simply press and hold the RESET button until the display
reads zero. The display will show the word “CLEAr” during
this process, and will show 0.0 when reset to zero is
complete.
4. To reset the seed and area counters; there are three
independent AREA counters, paired with three SEED
counters. The active pair of counters is indicated by
the small numbers in the lower right area of the display
(1,2, or 3) when the rotary switch is in the AREA or SEED
position. Select the pair of counters you want to use by
pressing the “+” button. The small number will increment
each time the “+” button is pressed (from 1 to 3, then rolls
back to 1). DO NOT attempt to select the counter number
by using the “-” button, because that will clear the active
pair of counters if held for 2 seconds. If the “-” button is
accidentally pressed, the console will display “CLEAr” to
alert the user that the counters will be cleared. If the user
continues to hold the “-” button for 2 seconds “CLEAr”
will disappear and be replaced by 0.0, indicating that the
selected pair of counters has been cleared.
Clearing Counters
When the desired counter number is displayed, press the
“-” (RESET) button and “CLEAr” will be displayed.
NOTE:
holding the “-” (RESET) button for 2 seconds will clear both
the #3 AREA counter
AND
the #3 SEEDS counter whether
the rotary switch is in the AREA or the SEEDS position.
If the
“-” button is released before 2 seconds have elapsed, the
counters will not be cleared and the “CLEAr” message will
be replaced with the previous total.
ROWS
SECTION
METER
CAL
ROW
SPACING
ADJUST
RATE
TARGET
RATE
SPEED
CAL
METER CAL
TEST
TEST
SPEED
RPM
(1) (2) (3)
DISTANCE
AREA /
HOUR
SEEDS
(1) (2) (3)
SEEDS /
DISTANCE
SPEED
AREA
(1) (2) (3)
ON
OFF
L
C
R
SECTIONS
RUN
HOLD
CAL
AUTO
MAN
RESET
ON / OFF
____
SEED RATE
SEED
SPACING
RATE 1
RATE 2
RATE 3
HOLD
V
2
ROWS
SECTION
METER
CAL
ROW
SPACING
ADJUST
RATE
TARGET
RATE
SPEED
CAL
METER CAL
TEST
TEST
SPEED
RPM
(1) (2) (3)
DISTANCE
AREA /
HOUR
SEEDS
(1) (2) (3)
SEEDS /
DISTANCE
SPEED
AREA
(1) (2) (3)
ON
OFF
L
C
R
SECTIONS
RUN
HOLD
CAL
AUTO
MAN
RESET
ON / OFF
____
SEED RATE
SEED
SPACING
RATE 1
RATE 2
RATE 3
HOLD
V
3
ROWS
SECTION
METER
CAL
ROW
SPACING
ADJUST
RATE
TARGET
RATE
SPEED
CAL
METER CAL
TEST
TEST
SPEED
RPM
(1) (2) (3)
DISTANCE
AREA /
HOUR
SEEDS
(1) (2) (3)
SEEDS /
DISTANCE
SPEED
AREA
(1) (2) (3)
ON
OFF
L
C
R
SECTIONS
RUN
HOLD
CAL
AUTO
MAN
RESET
ON / OFF
____
SEED RATE
SEED
SPACING
RATE 1
RATE 2
RATE 3
HOLD
V
1
36
HOLD
3
Display indicates counter pair #2 is selected
Display indicates counter pair #3 is selected
Display indicates counter pair #1 is selected
ROWS
SECTION
METER
CAL
ROW
SPACING
ADJUST
RATE
TARGET
RATE
SPEED
CAL
METER CAL
TEST
TEST
SPEED
RPM
(1) (2) (3)
DISTANCE
AREA /
HOUR
SEEDS
(1) (2) (3)
SEEDS /
DISTANCE
SPEED
AREA
(1) (2) (3)
ON
OFF
L
C
R
SECTIONS
RUN
HOLD
CAL
AUTO
MAN
RESET
ON / OFF
____
SEED RATE
SEED
SPACING
RATE 1
RATE 2
RATE 3
HOLD
V
3
After the “-” (RESET) button has been held for 3 seconds,
the “CLEAr” message will be replaced by 0.0, indicating that
counter pair #3 has been cleared
.
Содержание ProPlant
Страница 1: ...Reference Manual ProPlant TM Automatic Seed Rate Controller...
Страница 41: ...41 Appendices...
Страница 47: ......