Page 29
Electrical Installation
thermoMETER TIM 8 / thermoIMAGER TIM 40
6.1
Process Interface
6.2
Process Interface TIM 8
The thermoMETER TIM 8 is equipped with an integrated process interface (cable with terminal block included
in scope of supply), which can be programmed via the software as an direct analog input (AI) / digital input,
as an direct analog output (AO) in order to control the process or as an RS485 interface
1)
. The signal level is
0 - 10 V for AI, 24 V for DI and 0/4 - 20 mA for AO.
The process interface can be activated choosing the following options:
Analog Input (AI)
Emissivity, ambient temperature, reference temperature, uncommitted value, flag
control, triggered recording, triggered snapshots, triggered line-scanner, triggered
event grabber, reset peak-/valley-hold
Analog Output (AO)
Main measure area, measure area, internal temperature, flag status, alarm, frame
sync, fail-safe, external communication
1) Power supply only necessary when using the Ethernet connection (without PoE) or self-sufficient opera-
tion.