Page 23
Installation and Mounting
scanCONTROL 30xx
5.2
Connections
5.2.1
General
1
2
1 Multifunction socket (Power supply, IO)
2 Ethernet socket
Fig. 8 Output sockets arrangement
Designation Sensor connector Pin Cable color PCR3000-x
Notes
Connection view
+Ub
9
red
+ 11 V - 30 V DC
(rated value 24 V); max. 5 W
2
3
4
5
6
7
8
9
1
10
11
12
12-pin screw connector,
solder pin side (cable)
GND
2
blue
0 V
+Laser on/off
3
white
available with SI option
-Laser on/off
1
brown
RS422
12
red-blue
RS422
input respectively output
/RS422
11
gray-pink
GND RS422
10
purple
Ground connection RS422
In1
4
green
Switching input In1
In2
6
yellow
Switching input In2
In3
8
gray
Switching input In3
In4
5
pink
Switching input In4
GND-In
7
black
Ground connection In
Screen
Housing
black
Not electrically connected to GND
Fig. 9 Assignment of the multifunction socket on scanCONTROL 30xx
GND: Galvanically isolated from IN1, 2, 3, 4, RS422, Laser on/off
Laser on/off: Input galvanically isolated from GND IN, RS422
In1, In2, In3, In4, RS422: Inputs galvanically isolated from GND and Laser on/off