background image

1. 

Warnings

Avoid unnecessary laser radiation to be exposed to the human body.
Connect the power supply and the display-/output device according to the safety 

regulations for electrical equipment. The power supply must not exceed the specified 

limits.

 

> Risk of injury, damage to or destruction of the sensor
Avoid shocks and impacts to the sensor. Avoid exposure of sensor to aggressive 

materials (detergents, cooling emulsions).

 

> Damage to or destruction of the sensor
Avoid constant exposure of the sensor to dust or splashes of water by appropriate 

methods such as blowing or using a protective housing.

 

> Damage to or destruction of the sensor
Read the detailed instruction manual before operating the sensor. You will find this 

manual online at www.micro-epsilon.com.

2. 

Notes on CE Identification

The following applies to the scanCONTROL 25xx:  

 - EU Directive 2014/30/EU

 - EU Directive 2011/65/EU, “RoHS“ category 9

The sensor is designed for use in industry and satisfies the requirements. The sensor 

fulfills the specifications of the EMC requirements, if the instructions in the manual are 

followed.

3. 

Proper Environment

 - Protection class: 

IP 65

 - Operating temperature:  0 to +45 °C (+32 to +113 °F), by free circulation of air

 - Storage temperature: 

-20 to +70 °C ( -4 to +158 °F)

 - Humidity: 

5 - 95 % (non condensing)

4. 

Scope of Delivery of scanCONTROL 

25xx

 - 1 Sensor scanCONTROL 25xx with integrated controller

 - 1 Multifunction cable PCR3000-5, length 5 m; for power supply, trigger and RS422; 

M12x1 screw connector and free cable ends

 - Calibration final inspection / assembly instructions / 2 protective caps

Assembly Instructions
scan

CONTROL 

2500 / 2510

Содержание scanCONTROL 2500

Страница 1: ...r You will find this manual online at www micro epsilon com 2 Notes on CE Identification The following applies to the scanCONTROL 25xx EU Directive 2014 30 EU EU Directive 2011 65 EU RoHS category 9 T...

Страница 2: ...s used for the first time i If the information labels are hidden in the installed state the user must ensure that additional labels are fitted at the point of installation scanCONTROL 25xx sensors wit...

Страница 3: ...22 11 gray pink In1 6 yellow Switching input In1 GND In1 4 green Ground connection In1 In2 5 pink Switching input In2 GND In2 8 grey Ground connection In2 In3 10 purple Switching input In3 GND In3 7 b...

Страница 4: ...nal levels are switchable for all switching inputs between LLL TTL logic and HLL HTL logic LLL level Low 0 V 0 8 V high 2 4 V 5 V internal pull up resistor 10 k to 5V HLL level Low 0 V 3 V high 11 V 2...

Страница 5: ...et 169 254 x x No collision detection is implemented This is also the default setting The sensor supports DHCP This setting is activated by default and has priority over the retrieval in the link loca...

Страница 6: ...n Tools The following minimum system specification is necessary Windows 7 32 bit and 64 bit Windows 10 32 bit and 64 bit 800 MHz or faster 32 bit and 64 bit processor 512 MB RAM Screen resolution 1024...

Страница 7: ...Loosen the screws before you remove the connector from the socket Connect the shield of the power supply cable to the PE protective earth conduc tor of the main power supply Close unused connection p...

Страница 8: ...L can be accessed via GigEVision and GenICam for digital cameras via Ethernet interface SDK for fast application integration C C C and others For details how to access profile data refer to the enclos...

Страница 9: ...ms Furthermore all scanCONTROL sensor settings can be set via scanCON TROL Gateway e g Laser on off or switch User Mode Sensor parame terization Power supply Triggering Encoder Synchronization Mode co...

Страница 10: ...V 230 V 24 V 13 scanCONTROL 2510 with scanCONTROL Output Unit for Con 13 14 C D B A 750 626 Power jumper contacts Supply via power jumper contacts 24V Status voltage supply Power jumper contacts Syste...

Страница 11: ...field supply in of the OU Filter module to the power supply 0 V and 24 V resp 0 V and 5 V i The system supply and field supply should be separated to ensure the bus operation and electrical isolation...

Страница 12: ...rther Information Please refer to the enclosed online manual the section Status and Error Messages and Notes in the scanCONTROL Configuration Tools manual You will find details to the separate program...

Отзывы: