background image

Page 2

scanCONTROL 25xx

4. 

Laser Safety

The scanCONTROL 25xx/BL sensors operate with a semiconductor laser with a  
wavelength of 405 nm (visible/blue). Operation of the laser is indicated visually by the 
LED on the sensor, see operating instructions Chap. 3.3.  
When operating the scanCONTROL 25xx/BL sensors, the relevant regulations accord-
ing to IEC 60825, Part 1 of 05/2014 and the applicable accident prevention regulations 
must be followed. The laser warning labels for Germany have already been attached. 
For other non German speaking countries, an IEC standard label is included in delivery 
and the versions valid for the user’s country must be attached before the device is put 
into operation for the first time.

  If both warning labels are covered over when the unit is installed, the user must 

ensure that supplementary labels are attached.

Laser Class 2M

The sensors fall within laser class 2M (IIM). The laser is operated on a pulsed mode, 
the 

maximum optical power is ≤ 8 mW. 

Laser radiation. Close your eyes or immediately turn away if the 
laser beam hits the eye. Irritation or injury of the eyes possible.

Attach the following warning labels to the cover (front and rear side) of the sensor 
housing.

Laser warning sign and laser label LLT25xx-25/BL, LLT25xx-50/BL, LLT25xx-100/BL

COMPLIES WITH 21 CFR 1040.10 AND 1040.11 

EXCEPT FOR CONFORMANCE WITH 

IEC 60825-1 ED. 3., AS DESCRIBED IN

LASER NOTICE NO. 56, DATED MAY 8, 2019

Only for USA

i

 Mark the laser area recognizable 

and everlasting.

Содержание scanCONTROL 25 BL Series

Страница 1: ...d exposure of sensor to aggressive media detergents cooling emulsions Damage to or destruction of the sensor 2 Notes on CE Marking The following apply to the scanCONTROL 25xx BL measuring system EU Directive 2014 30 EU EU Directive 2011 65 EU The measuring system is designed for use in industrial applications The measuring system satisfies the requirements if the guidelines in the operating inst r...

Страница 2: ...st be attached before the device is put into operation for the first time i If both warning labels are covered over when the unit is installed the user must ensure that supplementary labels are attached Laser Class 2M The sensors fall within laser class 2M IIM The laser is operated on a pulsed mode the maximum optical power is 8 mW Laser radiation Close your eyes or immediately turn away if the la...

Страница 3: ...422 11 Gray Pink In1 6 Yellow Switching input In1 GND In1 4 Green Ground connection In1 In2 5 Pink Switching input In2 GND In2 8 Gray Ground connection In2 In3 10 Purple Switching input In3 GND In3 7 Black Ground connection In3 Screen Housing Black Not electrically connected to GND 2 3 4 5 6 7 8 9 1 10 11 12 GND galvanically isolated from In1 In2 In3 RS422 Laser on off Laser on off Input galvanica...

Страница 4: ...switching inputs together via software between LLL low voltage TTL logic and HLL high voltage HTL logic LLL Low 0 V 0 8 V high 2 4 V 5 V internal pull up 10 kΩ connected to 5 V HLL Low 0 V 3 V high 11 V 24 V up to 30 V are permissible internal pull up 10 kΩ connected to 24 V Pulse duration 5 µs External Laser Switch off Optional The external laser switch off is implemented as a hardware solution a...

Страница 5: ...P address in the link local net 169 254 x x No collision detection is implemented This is also the default setting The sensor supports DHCP This setting is activated by default and has priority over search the link local net The scanCONTROL 25xx BL sensor supports Power over Ethernet If the sensor is connected to a POE capable network adapter switch and you also use the power supply of the multifu...

Страница 6: ...ools The following minimum system requirements are necessary Windows 8 or 8 1 Windows 10 each 32 bit and 64 bit 1 GHz processor or faster 32 bit and 64 bit 1 GB RAM recommended 4 8 GB Screen resolution 1024 x 768 recommended 1920 x 1080 scanCONTROL 3D View The following minimum system requirements are necessary Windows 8 or 8 1 Windows 10 each 64 bit 1 GHz processor or faster 64 bit 1 GB RAM recom...

Страница 7: ... Close unused connection plugs with the included protective caps Turn on the power supply 24 VDC Please wait until the scanCONTROL measuring system is recognized by the PC This may take a few seconds Now you can operate the scanCONTROL measuring system with the scanCON TROL software packages i Operating the sensors via Ethernet may require the IP settings of the PC sensor or the firewall settings ...

Страница 8: ...ssed via GigEVision and GenICam for digital cameras via Ethernet interface SDK for fast integration into applications C C C and others Please refer to the respective SDK documentation for further information on accessing the profile data 10 Transmitting Measurement Results scanCONTROL 25xx BL offers the following options for transmitting measurement results Ethernet interface Modbus TCP protocol U...

Страница 9: ...these fieldbus systems Furthermore all scanCONTROL sensor settings can be set via the 2D 3D Gateway e g Laser on off or User Mode Sensor parameterization Supply voltage Triggering Encoder Synchronization Mode switching Sensor control Gateway parameterization USB Ethernet switch 2D 3D Gateway The 2D 3D Gateway can connect up to four scanCONTROL SMART sensors to the fieldbus Measurement values are t...

Страница 10: ...2 5 3 0 5 7 LINK ACT MS I O ETHERNET NS 8 7 6 5 4 3 2 1 N O LINK ACT 1 2 X 1 X 2 8 1 ON 24V X3 0V 0 WBM 255 DHCP OU fieldbus coupler L1 L2 L3 N PE OU Filter module OU Fieldbus coupler 13 14 C D B A 750 626 Ñ 2 5 3 0 5 7 LINK ACT MS I O ETHERNET NS 8 7 6 5 4 3 2 1 N O LINK ACT 1 2 X 1 X 2 8 1 ON 24V X3 0V 0 WBM 255 DHCP System supply Field supply 230 V 24 V 230 V 24 V 12 scanCONTROL 25xx BL with 2D...

Страница 11: ...tal output terminals need a field supply of 5 VDC or 24 VDC depending on the module type After mounting the modules install the required wiring Connect the System supply out contacts of the OU Filter module to the System supply in contacts of the OU Fieldbus coupler 0 V and 24 V Connect the system supply in of the OU Filter module to the power supply 0 V and 24 V Connect the field supply in of the...

Страница 12: ...or and free cable ends Calibration protocol assembly instructions 2 Protective caps 14 Additional Information Please refer to the enclosed online documentation the Status and Error Messages and Notes sections in the scanCONTROL Configuration Tools operating instructions You will find details about the individual programs in the respective operating instructions or in the operating instructions of ...

Отзывы: