Operation
English
optoCONTROL 1200/1201
Receiver
Pin
Signal
Color
PC120x
Power +24 VDC
Analog output 0 ... 10 VDC
V
I
Load
1
< 100 mA
4
GND
1
2
3
Fig. 11 Receiver wiring, load connected to GND,
(PNP acive light quantity < threshold)
1
+12 ... +32 VDC
Brown
2
Analog out
(0 ... 10 VDC)
White
3
GND (0 V)
Blue
4
Digital out
Black
Screen Housing
---
1
2
4
3
Power +24 VDC
Analog output
I
Load
1
< 100 mA
V
GND
0 ... 10 VDC
V
Fig. 12 Receiver wiring, load connected with +24 VDC,
(NPN active light quantity > threshold)
1) High side/low side switch. The load can be connected to +24 VDC or to GND.