![MICRO-EPSILON IF2030/PNET Скачать руководство пользователя страница 48](http://html1.mh-extra.com/html/micro-epsilon/if2030-pnet/if2030-pnet_operating-instructions-manual_1785372048.webp)
Page 48
Annex | Sensor Values, Data Format, Conversion
IF2030/PNET
A 4.4
INC5701
Baud rate
230400 b/s
RS485 half duplex max. sampling rate 250 Hz, ex factory INC5701D, Little Endian
Bus address 126
Byte
Meaning
Data format
Data[0]
Status byte (contains error flags, normaly 0x00)
8 bit
Data[1]
Long term values counter [bit 0:7]
Uint 32 bit
Data[2]
Long term values counter [bit 8:15]
Data[3]
Long term values counter [bit 16:23]
Data[4]
Long term values counter [bit 24:31]
Data[5]
Number of measured values in this package
8 bit
Data[6]
Padding byte
8 bit
Data[7]
Padding byte
8 bit
Data[8]
Measured value 1 [bit 0:7]
Float 32 bit
Data[9]
Measured value 1 [bit 8:15]
Data[10]
Measured value 1 [bit 16:23]
Data[11]
Measured value 1 [bit 24:31]
Data[12]
Measured value 2 [bit 0:7]
Float 32 bit
Data[13]
Measured value 2 [bit 8:15]
Data[14]
Measured value 2 [bit 16:23]
Data[15]
Measured value 2 [bit 24:31]
Fig. 23 Encoding of Measured Data in the Transmission Protocol, INC5701S