Page 16
Commissioning
IF2030/PNET
5.
Commissioning
5.1
Configuring the Sensors
The sensor used must be correctly configured to work with the IF2030. Micro-Epsilon recommends that the
sensor’s base configuration be set by using its web interface. The configuration can later also be adjusted via
fieldbus. Please refer to the operating instructions of the corresponding sensor for detailed information on config-
uring the sensor.
5.2
Baud Rate and Sensor Interface
IF2030/PNET must be set for the interface used and the sensor’s baud rate. The baud rate and sensor interface
can be configured in various ways.
Sensor/Controller Baudrate [Baud] RS485 RS422
Sensor/Controller Baudrate [Baud] RS485 RS422
ACC5703
230400
•
ILD1420
921600
•
ACS7000
230400
•
ILD1750
921600
•
DT6120
230400
•
ILD2300
921600
1
•
IFC24x1
115200
•
INC5701
230400
•
IFC242x
115200
•
ODC2520
115200
•
ILD1320
921600
•
Fig. 10 Baud rate (factory setting) of the sensors or controllers to be connected
5.2.1
Option 1: Basic Settings Module
After setting up the IF2030/PNET in the TIA portal, see Chap.
, the
Basic Settings
module offers an easy
way to specify the required settings.
Select the baud rate and interface as necessary, see Chap.
1) The ILD2300 is set for 691.2 kBaud ex factory. Increase the baud rate to 921.6 kBaud in the sensor.