Page 16
Commissioning
IF2030/ENETIP
5.
Commissioning
5.1
Configuring the Sensors
The sensor used must be correctly configured to work with the IF2030. Micro-Epsilon recommends that the sensor’s base configura-
tion be set by using its web interface. The configuration can later also be adjusted via fieldbus.
Please refer to the operating instructions of the corresponding sensor for detailed information on configuring the sensor.
5.2
Baud Rate and Sensor Interface
IF2030/ENETIP must be set for the interface used and the sensor’s baud rate.
Sensor/
Controller Baud rate [Baud] Bus address RS485 RS422
Sensor/
Controller
Baud rate [Baud] Bus address RS485 RS422
ACC5703
230400
126
•
ILD1750
921600
•
ACS7000
230400
•
ILD1900
921600
•
DT6120
230400
126
•
ILD2300
921600
1
•
IFC24x1
115200
•
INC5701
230400
126
•
IFC242x
115200
•
MSC7602
256000
•
ILD1320
921600
•
ODC2520
115200
•
ILD1420
921600
•
Fig. 11 Baud rate (factory setting) of the sensors or controllers to be connected
The baud rate and sensor interface are transferred with Class 0xA0 (Object), see Chap.
1) The ILD2300 is set for 691.2 kBaud ex factory. Increase the baud rate to 921.6 kBaud in the sensor.