Page 20
Commissioning
IF2030/ENETIP
5.4
Class Directory
Class Instance Attribute Data type
Name
RS485 RS422 Description
0x80
1
0
Uint8
RW Select sensor
Address of currently selected sensor
1
1
Uint8[32] R
Sensor addresses
Shows address list of available sensors
0x90
0
Uint32[64] R
Device error log
Reads out the last 32 error codes with time stamp
0xA0 1
0
Uint32
RW Baudrate
IF2030 baud rate
1
Uint8
RW Minimum cycle time
Minimum time for one communication cycle in ms,
cycle time = 0: use estimated time
2
Uint8
RW Preferred sensor
data size
Desired useful data length in bytes per sensor,
value = 0: estimated/calculated value
3
Uint8
RW Sensor interface
0: RS485,
1: Reserved,
2: ASCII + RS422
4
Uint8
W
Reset device config
One byte deletes settings from flash, settings are
included in RAM until restart
5
Uint8
W
Reset sensor config
One byte deletes settings from flash, settings are
included in RAM until restart
6
Uint8
W
Reset device
One byte performs reset
7
Uint8
RW enable/disable
HTTL Sync
0: Disable HTTL synchronization
1: Enable HTTL synchronization
8
Uint8
RW enable/disable cy-
clic status header
0: Disable 8 byte status header in cyclic data
1: Enable 8 byte status header in cyclic data
Содержание IF2030/ENETIP