Page 24
Operating
capaNCDT CST6110
Possibility 2:
Status LED
Open the controller housing.
Use the MODE switch to select operating mode
0
.
Use the
BLADES
switch to define the measuring object divider.
Controller electronics with
adjusting elements
Start to rotate the measuring object.
Screw a locknut on the sensor and carefully turn the sensor onto the thread of the housing.
The sensor position should always be fastened by the locknut, except while it is being screwed
onto the thread.
Observe how the color of the
Status
LED
changes
.
Status
LED:
turquoise
Too few pulses to
check the signal
transformation
- Measuring object does not turn/turns very slowly, see
Increase rotational speed
- Sensor identifies too few signal peaks
Continue to carefully screw in the sensor or increase the controller’s
sensitivity using the
Sens
potentiometer (sensitivity).
If sensitivity is at the maximum, continue to screw in the sensor.
Status
LED: red
Signal faulty
- Ridges/grooves are not identified as such
Carefully continue to screw in the sensor or increase the sensitivity
- Sensitivity is at the maximum, faults are detected as ridges/grooves
Reduce the sensitivity and continue to carefully screw in the sensor
Status
LED
:
green
Signal faultless
Pulses are detected at regular time intervals. The RAW signal is correctly transformed into digital pulses without
faults or pulse drops.