MICRO-EPSILON capaNCDT CST6110 Скачать руководство пользователя страница 10

Page 10

Delivery

capaNCDT CST6110

3. 

Delivery 

3.1 

Unpacking/Included in Delivery

1x CST6110 Controller
1x Power supply and signal cable SCAC3/6/IP
1x Quick Manual

Separately available:
CS025/M5-CAm1,0/RS sensor including integrated sensor cable

  Carefully remove the components of the measuring system from the packaging and ensure that the goods are forwarded in such 

a way that no damage can occur.

  Check the delivery for completeness and shipping damage immediately after unpacking. 
  If there is damage or parts are missing, immediately contact the manufacturer or supplier.

Other optional accessories are listed in the appendix.

3.2 

Storage

 - Storage temperature:

 

ƒ

Sensor and sensor cable: -50 ... +125 °C (-58 ... +257 °F)

 

ƒ

Controller:  

-40 ... +85 °C (-40 ... +185 °F)

 - Humidity: 

5 - 95 % (non-condensing)

Содержание capaNCDT CST6110

Страница 1: ...CSE025 M5 CAm1 0 RS Operating Instructions capaNCDT CST6110...

Страница 2: ...LON MESSTECHNIK GmbH Co KG K nigbacher Strasse 15 94496 Ortenburg Germany Tel 49 0 8542 168 0 Fax 49 0 8542 168 90 e mail info micro epsilon com www micro epsilon com Capacitive rotation speed measuri...

Страница 3: ...npacking Included in Delivery 10 3 2 Storage 10 4 Mounting 11 4 1 Sensor Sensor Cable 11 4 2 Controller 12 4 3 Power Supply and Signal Cable SCAC3 6 IP68 13 4 4 Electrical Connections 13 4 4 1 Power S...

Страница 4: ...capaNCDT CST6110 6 Troubleshooting 27 7 Liability for Material Defects 28 8 Service Repair 28 9 Decommissioning Disposal 28 Appendix...

Страница 5: ...t avoided Indicates a user action i Indicates a tip for users Measurement Indicates hardware or a software button menu 1 2 Warnings Connect the power supply and the display output device according to...

Страница 6: ...counting tasks The system must only be operated within the limits specified in the technical data see Chap 2 4 The system must be used in such a way that no persons are endangered or machines and othe...

Страница 7: ...or This change in capacitance is detected and analyzed by the controller The rotational speed of measuring objects made of non conductive materials is also measured This requires a shorter distance be...

Страница 8: ...range Storage 40 85 C 40 185 F Operation 40 85 C briefly up to 125 C Shock DIN EN 60068 2 27 20 g 5 ms in 3 axes 1000 shocks each Vibration DIN EN 60068 2 6 10 g 10 2000 Hz in 3 axes 10 cycles Protect...

Страница 9: ...c 25 mm Mounting Screw connection via M5 thread Temperature range Storage 50 125 C 58 257 F Operation 50 125 C Humidity 0 95 r H non condensing Shock DIN EN 60068 2 27 50 g 5 ms in 3 axes 1000 shocks...

Страница 10: ...the measuring system from the packaging and ensure that the goods are forwarded in such a way that no damage can occur Check the delivery for completeness and shipping damage immediately after unpack...

Страница 11: ...Never bend the sensor cable more tightly than the permitted bending radius 10 x diameter for dynamic use 5 x diameter for static use i The calibrated sensor cables must not be short ened because this...

Страница 12: ...T CST6110 4 2 Controller The controller can be fastened by using two M4 screws 43 1 69 12 47 52 2 05 42 1 65 24 94 18 71 53 2 09 15 3 60 24 94 6 24 30 1 18 Mounting holes for M4 screws Fig 3 Dimension...

Страница 13: ...r pin side 6 pole cable connector Fig 4 Supply voltage connection 24 V 1 White 24 V supply 11 32 VDC reverse polarity protection 0 V 2 Gray Supply ground Analog out 3 Pink Signal output 0 5 V AGND 4 G...

Страница 14: ...reversal i Power supply only for measuring devices not to be used for drives or similar sources of impulse interference at the same time MICRO EPSILON recommends the PS2020 power supply unit see Optio...

Страница 15: ...he system detects ridges and grooves The sensor front may not touch the measuring object ridge Damage to or destruction of the sensor i The vibrations of a rotating mechanical shaft cause slightly lar...

Страница 16: ...g claws on the plug connector snap into the device component and create a reliable connection between the two compo nents It cannot be separated by pulling on the plug connector s cable By contrast th...

Страница 17: ...identified Rotational speed mea surement Green Measurement inside the measuring range Orange Measurement outside the measuring range MODE rota ry switch Description Measuring range Number of blades X...

Страница 18: ...not possible The controller evaluates the pulses provided by the sensor For the Rotational speed measurement modes MODES 7 8 9 and TTL pulse per rotation MODE 3 the controller must know the number of...

Страница 19: ...sition should always be fastened by the locknut except while it is being screwed onto the thread Observe how the color of the Status LED changes Status LED turquoise Too few pulses to check the signal...

Страница 20: ...sor and ridge ap prox 5 mm Carefully continue to screw in the sensor i The connector on the sensor cable can be turned in the socket without needing to be pulled off You can continue to screw in the s...

Страница 21: ...GNAL 2V Div TTL Fig 17 Screenshot of oscilloscope short distance low sensitivity Signals on oscilloscope after distance between sensor and measured object has been reduced without changing sensitivity...

Страница 22: ...tance between the sensor and the measuring object min max Sensitivity potentiometer Status LED turquoise Measurement not possible RAW SIGNAL 2V Div TTL Fig 18 Screenshot of oscilloscope long distance...

Страница 23: ...RAW signal is correct ly transformed into digital pulses without faults or pulse drops Status LED green Measurement possible RAW SIGNAL 2V Div TTL Fig 21 Screenshot of oscilloscope short distance low...

Страница 24: ...nal transformation Measuring object does not turn turns very slowly see Fig 10 Increase rotational speed Sensor identifies too few signal peaks Continue to carefully screw in the sensor or increase th...

Страница 25: ...tch for the output test Pin 3 analog output 1 V 1 5 V 2 V 5 V for measuring object dividers from 1 10 0 V for measuring object dividers from 11 16 Pin 5 TTL pulses t i approx 100 s t p varies dependin...

Страница 26: ...r max 100 000 rpm Fig 25 Signal for max 200 000 rpm Fig 26 Signal for max 400 000 rpm The controller outputs an analog signal for the operating modes 0 Signal test 4 5 6 Frequency measurement 1 Output...

Страница 27: ...bed see Chap 5 4 Change the sensitivity on the controller Change the distance between sensor and measured object Provide the controller with its own power supply If you use measuring devices e g an os...

Страница 28: ...MICRO EPSILON shall not be liable for any consequential special indirect or incidental damage In the interest of further development Micro Epsilon reserves the right to make design changes without no...

Страница 29: ...Page 29 Appendix capaNCDT CST6110 Appendix Optional Accessories PS2020 Power supply unit for DIN rail mounting Input 230 VAC Output 24 VDC 2 5 A...

Страница 30: ...KG K nigbacher Str 15 94496 Ortenburg Germany Phone 49 8542 168 0 Fax 49 8542 168 90 info micro epsilon de www micro epsilon de Your local contact www micro epsilon com contact worldwide X9751420 A01...