Page 42
Installation and Assembly
capaNCDT 6100
Installation and Assembly
4.
Precautionary Measures
4.1
No sharp-edged or heavy objects may come into contact with the sensor cable sheath.
Protect the cable in pressurised rooms against pressure loads.
The minimum bending radius is 10 mm (.39 inch). Avoid kinks at all cost.
Check the connections for tight fit.
i
A damaged cable cannot be repaired.
4.2
Sensor
The sensors of the capaNCDT 6100 may be mounted free-standing or flush.
When assembling, make sure that the polished sensor surface is not scratched.
Sensor Radial Point Clamping with Grub Screw
4.2.1
This simple type of fixture is only recommended for a force and vibration-free installation position. The grub
screw must be made of plastic so that it cannot damage or deform the sensor housing.
Grub screw
Radial point clamping with grub screw
Fig. 3
Do not use metal grub screws!
Danger of damaging the sensor
>