Micon M1500-600/150kW 50Hz
Manual
UK1500.PM6
Rev. 95-06-23 OKK
Technical specifications
5
Electronic controls
5.3
Electrical construction
5.2
35
YAW SYSTEM
Yaw collar
: Rothe Erde ball ring with
internal toothing
Lubrication of bearings
: Mobilux 2/ Mobilith 460
Lubrication of teeth
: Rochol or similar
Yaw gear
: Bonfiglioli tooth wheel/planet
Lubrication
: Shell Tivela Compound A /Oil WB
Yaw motor
: Asynchronised brake motor
Yaw brakes
: 2 x Micon 1000
Control system
- Ensures automatic cut-in of generator
- Display with fault indicators ensures quick fault identification in the event of breakdown.
- Automatic restart after fault occurrence (see fault code table).
- Micon windmills are fitted as standard with condensators that have an equal
capacity to the generator's idling consumption of reactive effect.
- Overvoltage protection against lightning strike.
- Electronic cut-in equipment to limit the effects of cut-in surge on the generator's
fully laden current.
COMPUTER MANAGEMENT SYSTEM: (OPTIONAL EXTRA)
This system connects all Micon windmills in a windmill park together, and links them to a central
computer. It is then possible to obtain constant information on each individual machine's
performance. All recording of production and warranty information is automatic with direct access for
central administration
GENERATOR
Manufacturer
: Elin
Type
: Asynchronised - 3 phased
Output
: 600/150 //500/125 kW 690V 50/60 Hz
Protection class
: IP 54
Lubrication
: Mobiltemp SHC 100 grease
Weight
: 2850 kg
Computer
: MITA WP 2000
Cut-in module
: MITA WP 2050/2060