background image

2

TABLE OF CONTENTS

PAGE:

VERIFICATION OF OPERATOR AND HARDWARE 

 3

SPECIFICATIONS  

 4

SAFETY INSTRUCTIONS  

 5

INSTALLATION  

 6

ELECTRICAL CONNECTIONS AND SETTINGS  

 10

LIMIT SWITCH ADJUSTMENT  

 20

PHOTOCELL INSTALLATION INSTRUCTIONS  

 21

EMERGENCY MANUAL OPERATION  

 24

OPERATOR MAINTENANCE  

 25

MECHANICAL DRAWINGS AND PARTS LISTS  

 26

ELECTRICAL DIAGRAMS  

 28

WARRANTY  

 32

     WARNING

DO NOT CONNECT TO ELECTRICAL

 POWER DURING INSTALLATION 

OR SERVICING OF OPERATOR

IMPORTANT

FOR ANY QUESTIONS CONCERNING THE SAFETY OR 

OPERATION OF THIS OPERATOR PLEASE CONTACT 

MICANAN SYSTEMS AT 1-877-888-1116

SAVE THESE INSTRUCTIONS

For more information, please visit www.devancocanada.com 

or call toll free at 855-931-3334

Содержание Pro-APTC

Страница 1: ...installation instruction manual Serial Installation Date Wiring Diagram PRO APTC...

Страница 2: ...OPERATION 24 OPERATOR MAINTENANCE 25 MECHANICAL DRAWINGS AND PARTS LISTS 26 ELECTRICAL DIAGRAMS 28 WARRANTY 32 WARNING DO NOT CONNECT TO ELECTRICAL POWER DURING INSTALLATION OR SERVICING OF OPERATOR I...

Страница 3: ...is shipped with rails drive chain carriage and the straight bar of the trolley arm already assembled Check that along with your operator rail assembly you have received the following standard hardware...

Страница 4: ...UCTION Heavy duty worm gear reducer 40 1 reduction or 25 1 high speed VFD option OUTPUT SHAFT SPEED 40 RPM DOOR SPEED standard 7 second BRAKE Model PRO APTCB Magnetic braking system to prevent coastin...

Страница 5: ...the door system READ AND FOLLOW ALL INSTALLATION INSTRUCTIONS Commercial door operators are never to be installed on a residential installation Install only on a properly operating and balanced door A...

Страница 6: ...n 1 Install control station away from all moving door parts within sight of the door and a minimum of 5 ft 1 5 m from the ground 2 Install entrapment warning sign next to control station INSTALLATION...

Страница 7: ...e above the door Fig A 2 Open door and mark the center line of the door on the ceiling Fig B 3 Determine the highest point of door travel by manually opening the door Using a carpenter s level project...

Страница 8: ...centered with door and positioned so that these holes are 2 1 2 6 5 cm above the high arc line of door Secure wall mounting bracket by welding or using suitable hardware 8 Swing the operator above th...

Страница 9: ...door Adjust length of 2 piece trolley arm accordingly Using suitable hardware Align door bracket with centerline of door and secure to door using suitable hardware 10 For high ceiling applications in...

Страница 10: ...r to connection of power supply or control station ELECTRICAL CONNECTIONS IMPORTANT EACH INDIVIDUAL COMMERCIAL DOOR OPERATOR MUST HAVE IT S OWN DEDICATED POWER SUPPLY MICANAN HIGHLY RECOMMENDS THAT EA...

Страница 11: ...e terminal strip must remain connected MOTOR DIRECTION VERIFICATION Make sure the mode of operation is selected to D1 After electrical power connections are made manually move door to mid position Usi...

Страница 12: ...not connected in B2 T and Ts modes door can only be closed by constant pressure on close and if constant pressure is removed before door reaches full close position door reverses to full open Note Onl...

Страница 13: ...1 mode setting please read all modes of Operation and determine which operational mode is desired B2 Momentary on open and close Open Button Momentary activation opens the door When door is closing mo...

Страница 14: ...Momentary contact from mid stop opens the door to full open position Constant activation when door is opening bypass mid stop if enabled Close button Constant pressure on close Door reverses to full o...

Страница 15: ...Momentary activation refreshes the timer to close Timer to close Closes the door from mid stop or full open Momentary activation of stop button will de activate the timer Timer resumes its normal oper...

Страница 16: ...d T modes of operation Delay on close timer is OFF when the Delay on close dial is set to OFF position To adjust this timer rotate the dial clockwise to the desired value The minimum value for delay o...

Страница 17: ...or is opening Dry contact status for door closing status Contact closes when door is closing Dry contact for door full open status Contact closes when door is fully open Dry contact for door full clos...

Страница 18: ...eat transmitter programming steps for additional transmitters OPERATION 1 Press and release the button on MICANAN transmitter 2 Receiver LED will light momentarily and door will cycle TO ERASE ALL LEA...

Страница 19: ...elay on close timer Blinking Delay on close timer is counting Selector dial is set to Run timer Timer to close Blinking Timer to close is counting Safety Photo ON Primary safety devices not connected...

Страница 20: ...reversing device from reversing door when door is almost fully closed To adjust door travel 1 Open cycle Depress cam plate and spin Open limit cam away from Open limit switch to increase door travel...

Страница 21: ...tal injury Follow these instructions carefully WARNING Keep fingers and other body parts away from all moving parts of the door operator system while the system is being operated WARNING To prevent un...

Страница 22: ...Turn the power on to the operator Align transmitter and receiver by adjusting height of the fixture Fig 4 3 Pair the two white wires and the two black wires together from transmitter and receiver to a...

Страница 23: ...erminals on the logic board or interface module if applicable as shown in Fig 4 Use minimum 18 gauge wires and secure the wires to wall or ceiling 7 Turn the power on to the operator Align transmitter...

Страница 24: ...engages carriage EMERGENCY MANUAL OPERATION The operator is equipped with a dual handle quick release disconnect system to manually operate door in case of emergency This feature should not be used to...

Страница 25: ...ucer and operator runs smoothly and quietly Verify that carriage runs smoothly on tracks Every 6 months 1 Verify tightness of all fasteners and set screws 2 Verify that operator is properly secured 3...

Страница 26: ...DATE I APPROVED I DRAWN BY UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN INCHES TOLERANCES XX 01 ANGLES 30 RIBVJI ON A MKCANAN Y IBM lINC TITLE MATERIAL JPRO APrC EIGHT SIZE lb I A CAD FILE PRD APTC XE...

Страница 27: ...4 MF00011 50 H H BOLT 3 8 16UNC X 3 4 LONG 8 MQ00008 51 SET SCREW 5 16 18 4 MQ00009 52 SET SCREW 1 4 20 4 MF00046 53 H H SLOTTED SELF ROUNDING WASHER HEAD SCREW 10 32 UNF x 1 2 13 CODE PART DESCRIPTIO...

Страница 28: ...MICANAN Commercial Door Opening Devices 3 1 2 4 5 6...

Страница 29: ...MICANAN Commercial Door Opening Devices 4 1 2 3 5 6...

Страница 30: ...MICANAN Commercial Door Opening Devices 4 1 2 3 5 6...

Страница 31: ...Notes...

Страница 32: ...PARTS DEVANCO CANADA 19192 HAY ROAD UNIT Q SUMMERSTOWN ON K0C 2E0 TOLL FREE 855 931 3334 www devancocanada com WHEN ORDERING REPAIR PARTS PLEASE SUPPLY THE FOLLOWING INFORMATION 3 PART NUMBER 3 DESCRI...

Отзывы: