background image

IM3061 

01/2020 

REV03 

SPEEDTEC 505SP BR 

OPERATOR’S MANUAL 

ENGLISH 

Lincoln Electric Bester Sp. z o.o.

 

ul. Jana III Sobieskiego 19A, 58-263 Bielawa, Poland 

www.lincolnelectric.eu 

Содержание SPEEDTEC 505SP BR

Страница 1: ...IM3061 01 2020 REV03 SPEEDTEC 505SP BR OPERATOR S MANUAL ENGLISH Lincoln Electric Bester Sp z o o ul Jana III Sobieskiego 19A 58 263 Bielawa Poland www lincolnelectric eu ...

Страница 2: ...ence record in the table below your equipment identification information Model Name Code Serial Number can be found on the machine rating plate Model Name Code Serial number Date Where Purchased ENGLISH INDEX Technical Specifications 1 Electromagnetic Compatibility EMC 2 Safety 3 Intoduction 5 Installation and Operator Instructions 5 WEEE 10 Spare Parts 10 Authorized Service Shops Location 10 Elec...

Страница 3: ...Output Voltage GMAW 60Vdc 60 500A 39Vdc 100 390A 33 5Vdc FCAW 60Vdc 60 500A 39Vdc 100 390A 33 5Vdc SMAW 60Vdc 60 500A 40Vdc 100 390A 35 6Vdc GTAW 60Vdc 60 500A 30Vdc 100 390A 25 6Vdc WELDING CURRENT RANGE GMAW FCAW SMAW GTAW 20A 500A 20A 500A 5A 500A 5A 500A RECOMMENDED INPUT CABLE AND FUSE SIZES Fuse Type gR or Circuit Breaker Type Z Power Lead 380V 40A 4 Conductor 4mm2 440V 32A DIMENSION Weight ...

Страница 4: ...esses Equipment for calibration and measurement Personal medical devices like pacemakers and hearing aids Check the electromagnetic immunity for equipment operating in or near the work area The operator must be sure that all equipment in the area is compatible This may require additional protection measures The dimensions of the work area to consider will depend on the construction of the area and...

Страница 5: ...AL OPTICAL RADIATION According with the requirements in 2006 25 EC Directive and EN 12198 Standard the equipment is a category 2 It makes mandatory the adoption of Personal Protective Equipment PPE having filter with a protection degree up to a maximum of 15 as required by EN169 Standard FUMES AND GASES CAN BE DANGEROUS Welding may produce fumes and gases hazardous to health Avoid breathing these ...

Страница 6: ...g away from those parts during machine starting operating and servicing SAFETY MARK This equipment is suitable for supplying power for welding operations carried out in an environment with increased hazard of electric shock The manufacturer reserves the right to make changes and or improvements in design without upgrade at the same time the operator s manual ...

Страница 7: ...or equipment damage Read the section on electromagnetic compatibility in this manual Do not operate in areas with an ambient temperature greater than 40 C Duty cycle and Overheating The duty cycle of a welding machine is the percentage of time in a 10 minute cycle at which the welder can operate the machine at rated welding current Example 60 duty cycle Welding for 6 minutes Break for 4 minutes Ex...

Страница 8: ...idual code digits are flashed in red with a long pause between digits If more than one code is present the codes will be separated by green light Read the error code before the machine is turned off If occurs to clear the error try to turn Off the machine wait for a few seconds then turn ON again If the error remains a maintenance is required Please contact the nearest authorized technical service...

Страница 9: ...s chapter Description of the User Interface is available in the operator s manual od wire feeder IM3028 IM3034 IM3045 IM3046 IM3052 IM3053 and the Guide supplied with a Replaceable Front Panel Welding Cables Connection Insert the plug of the work lead into the socket 5 The other end of this lead connects to the work piece with the work clamp Connect the wire feeder to the power source Insert the p...

Страница 10: ... indicator 3 will turn on The power source is also electronically protected against overload and accidental short circuit The overload and short circuit protection circuit automatically reduces the output current to a safe value when it detects an overload Transport Lifting WARNING Falling equipment can cause injury and damage to unit Figure 8 During transportation and lifting with a crane adhere ...

Страница 11: ... be disconnected from the machine before each maintenance and service After each repair perform proper tests to ensure safety Customer Assistance Policy The business of The Lincoln Electric Company is manufacturing and selling high quality welding equipment consumables and cutting equipment Our challenge is to meet the needs of our customers and to exceed their expectations On occasion purchasers ...

Страница 12: ...er is not listed Contact the Lincoln Electric Service Department for any code number not listed Use the illustration of assembly page and the table below to determine where the part is located for your particular code machine Use only the parts marked X in the column under the heading number called for in the assembly page indicate a change in this printing First read the Part List reading instruc...

Страница 13: ...CI Lincoln Arclink Communication Interface K14106 1 PF40 Digital Wire Feeder K14107 1 PF42 Digital Wire Feeder K14108 1 PF44 Digital Wire Feeder K14109 1 PF46 Digital Wire Feeder K14110 1 PF22 Digital Wire Feeder K14138 1 PF26 Digital Wire Feeder K14121 1 Replaceable Front Panel with User Interface U2 K14122 1 Replaceable Front Panel with User Interface U4 K14123 1 Replaceable Front Panel with Use...