OPERATION MANUAL

       IAQ CARBON DIOXIDE

    (CO

2

) MONITOR / LOGGER

Monitor
98136

98137(Backlight)

98138

98139 (Backlight)

Logger
98536

98537(Backlight)

98538

98539(Backlight)

Содержание 98136

Страница 1: ...OPERATION MANUAL IAQ CARBON DIOXIDE CO2 MONITOR LOGGER Monitor 98136 98137 Backlight 98138 98139 Backlight Logger 98536 98537 Backlight 98538 98539 Backlight...

Страница 2: ...P Reminder Logger status Logger setting Schedule Real time Key start mode Zoom in zoom out 15 Specifications 16 Trouble shooting CE 17 Warranty 18 CO2 levels and guide lines Operation a Power on off b...

Страница 3: ...nvisible and odorless an increased CO2 content makes is apparent because human will notice increased fatigue and reduced concentration FEATURES 1 Super large LCD simultaneously display of CO2 level Te...

Страница 4: ...pm a 700ppm 4 icon 700ppm a 1000ppm 5 icon 1000ppm a 2500ppm 6 icon 2500ppm a 5000ppm 7 icon 5000ppm 8 Air Temp Ambient Temperature 9 DPT Dew point temperature 10 WBT Wet bulb temperature 11 MH Month...

Страница 5: ...ly LCD shows current CO2 RH Temperature Date and Time Six 6 smiley icons indicate the indoor air quality level and appear on the top of first layer display SEL R Edit Date Time or alarm level TRH M Te...

Страница 6: ...old the meter close to your mouth or any other source of CO2 RECORDING MEASUREMENT Model 9853X series While recording the green LED light is flashing and Logging icon is flashing on LCD too If you hav...

Страница 7: ...2 VENT R lps ppm CO2 VENT R cfm p ppm TWA STEL lps cfm p Note 2 98138 98139 98538 98539 only a TWA Time Weighted Average 8 hours The meter keeps updating the reading every minute If the meter has been...

Страница 8: ...eed 490 l s we don t need ventilate 1 400 l s for saving energy o HUMIDITY WET BULB HUMIDITY DPT WBT o HUMIDITY DEW POINT HUMIDITY o AIR TEMP HUMIDITY TEMPERATURE HUMIDITY Ref 2 d TRH MODE Temperature...

Страница 9: ...s ON when the meter is turned on ABC is designed to calibrate the meter at the minimum CO2 reading detected during 7 5 days continuous monitoring power on e Temperature unit C or F selection Press UNI...

Страница 10: ...l or convenient stores the ABC function should be turned off for not being calibrated with high CO2 level When adaptor plug in long press POWER button to turn off the meter Hold MODE UNIT and press PO...

Страница 11: ...G FUNCTION 98536 98538 98537 98539 If you want record the CO2 concentration Temp RH plug with supplied USB cable as below to do the on line logging function Model 98137U or 9853x series NOTE Ensure to...

Страница 12: ...to the next setting After Month and date setting it displays Hour and Minute the same operation to set up always press TRH M to save and exit Setting Month M D Setting Date M D Setting Year When the...

Страница 13: ...ll show A on on the top layer of display press SEL R button to select Alarm on or off If alarm is on press TRH M button to save the setting and move to CO2 alarm setting d CO2 alarm level setting The...

Страница 14: ...110 exe for installation the driver B Install the logger software for Windows XP Please follow the following steps to install the software 1 Put CD into CD driver click Setup exe MSI Installer Bootstr...

Страница 15: ...Installed the USB driver computer will automatically detect logger click My computer Content in hardware content click Device manager to find the listed COMx listed under Ports COM LPT as below with...

Страница 16: ...ress SETTING button to enter Log setting pic 1 Note If logger is not plugged in USB port the warning message Reminder Data Logger is not plugged in USB port shows below pic 2 Make sure logger is plugg...

Страница 17: ...N A for non LCD models Press ON Logger LCD still illuminated after complete recording or OFF LCD is not illuminated after complete recording Press OK after selection ALARM SENSOR Pic 4 Select Temp Hum...

Страница 18: ...ecording Key start mode Select the mode to record once press the POWER button Roll over mode Select the mode to record after download the data without reset up each parameter and selection Only Real t...

Страница 19: ...button to select file and show the graph Save data Press SAVE button to save txt file Or Excel PDF file Available soon by updating newest logger software version Print graph Press PRINT button and pr...

Страница 20: ...mode N A N A YES YES Temp rang e 10 50 40 85 10 50 40 85 Temp accuracy RH range RH accuracy TWA STEL N A YES N A YES VENT rate lps cfm P N A N A N A YES Dew Point Temp N A YES N A YES Wet Bulb Temp N...

Страница 21: ...mp sensor is failed E 4 Operation Temp is too high E 5 Operation Temp is too low E 6 Some hardware are failed Note If above error codes appear on the display please contact with local distributor for...

Страница 22: ...instructions manual or improper combination with incompatible accessories or equipment or by previous attempts for repair carried out by none skilled or unauthorized personnel WARRANTY This instrumen...

Страница 23: ...average in occupational exposure limit is 5000ppm CO2 LEVELS AND GUIDELINES Non enforced reference levels a 250 350ppm Background normal outdoor air level b 350 1 000ppm Typical level found in occupie...