18
Operator's Manual
MAINTENANCE CHART
PROCEDURE
DAILY
3 MONTHS
6 MONTHS
9 MONTHS
12 MONTHS
Inspect electrical cord
X
Test GFCI (according to instructions
on GFCI).
X
Check water pump oil level
X
Oil leak visual inspection
X
Fuel leak visual inspection
X
Water leak visual inspection
X
Hose visual inspection
X
Water strainer inspection
X
High pressure nozzle inspection
X
Fuel filter/water sep. inspection
X
Change water pump oil **
X
X
X
X
Replace high pressure nozzle***
X
X
X
X
Inspect belt
X
X
X
X
Check burner air adjustment
X
X
X
X
Test water pressure*
X
X
X
X
Test water temperature*
X
X
X
X
Replace fuel filter
X
X
Test fuel pressure*
X
Delime coil****
X
Test voltage and amp draw*
X
Inspect fuel pump filter*
X
Check burner electrodes*
X
Replace fuel nozzle*
X
*
Should be performed by an authorized service technician.
** The pump oil must be changed after the first 50 hours of operation and every 500 hours or 3 months, whichever
comes first.
*** High pressure nozzle should be replaced whenever pressure is less than 85%.
**** Scale build up will vary with mineral content in the water and amount of usage. Deliming can range from weekly
to yearly maintenance.
STORAGE & MAINTENANCE
Содержание HHB Series
Страница 8: ...8 Operator s Manual HHS FEATURES FEATURES HHS_HHB 021714 RJA ...
Страница 32: ...32 Manuel de l utilisateur ÉLÉMENTS CONSTITUTIFS DU HHS FEATURES HHS_HHB 021714 RJA ...
Страница 73: ...Manual del operario de las lavadoras de chorro a presión 73 NOTA ...
Страница 74: ...74 Manual del operario de las lavadoras de chorro a presión NOTA ...