10
Description Housing Receiver
To open the receiver housing, the screw on the right must be removed. Then the upper shell of the housing
can be unhooked, the wall mounting plate mounted on the wall and the electrical connection carried out.
Commissioning
1.
Insert batteries in the transmitter/thermostat
2.
Connect the receiver to the 230V power supply
3.
Connect the consumer in accordance with the currently valid regulations.
4.
The device is ready for operation.
Description of the receiver Key and LEDs
The on/off button on the receiver can be used to completely deactivate the consumer (all LEDs not off). In
this case the receiver no longer responds to the radio commands of the transmitter/thermostat.
LED1 (
red
) ON = receiver is ready to receive
LED2 (
red
) OFF = receiver is off and not ready to
receive / consumer is switched off
LED2 (
green
) ON = consumer is switched on
LED2 (
green
) OFF = consumer is switched off
LED3 (
yellow
) ON = reception status coupling
LED3 (
yellow
) flashes = reception of radio
commands