See diagrams above for the recommended 
distance from combustible materials. 
However, any household furnishings should 
be at least 1000mm away as they could be 
adversely affected by heat
If the stove is to be installed in a non 
combustible recess it is recommended that 
100mm clearance is left at the back and sides 
for maintenance and to allow air to circulate 
around the stove.
Due to the heat of a hot stove, a suitable fire 
guard should be used to provide additional 
protection. 
Never allow young children to be left 
unsupervised in a room containing a hot stove.

VENTILATION 

Your stove requires ventilation to supply it 
with air for combustion. 
Ventilation is also required to ensure the 
proper operation of flues and chimneys to 
ensure that the products of combustion are 
safely dispersed to the outside air. Please 
ensure the stove has sufficient ventilation for 
operation. 
Extraction fans lower the pressure in a building 
which can cause spillage of combustion 

SOLWAY MEDIUM

SOLWAY LARGE

500

500

600

500

200

200

500

Minimum distance to combustible wall

Floor Protector 

Minimum Size (mm)

500

500

750

500

200

200

800

Minimum distance to combustible wall

Floor Protector 

Minimum Size (mm)

products from an open-flued appliance. This 
can occur even if the appliance and the fan 
are in different rooms. 
If mechanical extraction is unavoidable in 
the same room as your stove, then seek 
specialist advice to ensure safe operation of 
the appliance. 
A competent installer should be aware of 
specific ventilation parameters. 
Building control guidance for heat producing 
appliance ventilation can be found at: https://
www.hetas.co.uk/19223/ 

FLOOR

National and local building regulations must 
be complied with when considering the floor 
or hearth where the stove is to be installed. 
The floor must be capable of bearing the 
weight of the stove and the maximum hearth 
temperature measured on testing was above 
100 deg C on full fire. 

THE CHIMNEY

The stove is supplied with a flue pipe 
connector for top or rear mounting with the 
fixing screws supplied. The stove should 
never be connected to a shared chimney/flue 
system.

Содержание 141-L-SOLWAY

Страница 1: ...User Installation Manual Version 2 2020 02 22 www mi fires com BS EN 13240 2001 A2 2004 Tested as intermittent appliances burning wood logs MODEL Solway Small Solway Medium Solway Large ...

Страница 2: ...and smoke control areas 3 2 Product Specification 4 3 Important information about installing and using the stove 5 4 Unpacking Assembly 6 5 Installation of the stove 6 6 Operating Instructions 8 7 Guidance on safe operation 10 8 Maintenance 11 9 Fault Finding 12 10 CE Data plates 13 ...

Страница 3: ...y Welsh Ministers and by the Department of the Environment respectively Further information on the requirements of the Clean Air Act can be found here https www gov uk smoke control area rules Your local authority is responsible for implementing the Clean Air Act 1993 including Designation and supervision of smoke control areas and you can contact them for details of Clean Air Act requirements The...

Страница 4: ...GS Dimensions WxDxH mm 470mm max footprint exc handle x 300mm max footprint exc handle x 530mm exc flue Flue size 125mm WOOD LOGS RESULTS PARAMETER SMALL MEAN MEDIUM MEAN LARGE MEAN Total efficiency 75 4 75 6 79 6 Nominal heat output 4 1 kW 5 0 kW 8 0 kW Mean CO2 emission 7 64 9 09 11 20 Mean CO emission 0 10 0 14 0 13 Mean CO emission at 13 O2 0 10 0 12 0 10 Mean flue gas temperature 246 ºC 282 º...

Страница 5: ...ng purposes only Burn only approved fuels Wood or manufactured smokeless fuel Do not use petroleum based products or use as an incinerator This stove will become very hot whilst in operation and due care should be taken Thick gloves should be used to operate the primary secondary controls or reaching inside the stove to position fuel or remove ash Do not place flammable objects on or near the stov...

Страница 6: ...tured using the screws supplied Ensure the fireproof gasket is correctly seated in the base of the flue adaptor 2 Install the blanking plate in the rear of the stove when the normal flue exit is required If the rear mounting flue configuration is to be used the blanking plate will be fitted to the top of the stove and the flue connector to the rear panel 3 Set ashpan in position as shown as pictur...

Страница 7: ...f combustion SOLWAY MEDIUM SOLWAY LARGE 500 500 600 500 200 200 500 Minimum distance to combustible wall Floor Protector Minimum Size mm 500 500 750 500 200 200 800 Minimum distance to combustible wall Floor Protector Minimum Size mm products from an open flued appliance This can occur even if the appliance and the fan are in different rooms If mechanical extraction is unavoidable in the same room...

Страница 8: ...rning mineral fuel and secondary air when burning wood The need for de ashing the appliance more frequently when burning mineral fuel By adjusting the degree to which the primary air and air wash vents are opened good control of the combustion is being established The air wash feature when used should function to effectively keep the inside of the door glass clear of smokey deposits WARNING The te...

Страница 9: ...r door left open for long periods The stove door should never be left open when the stove is in use Under normal chimney draft conditions expect to refuel the stove every 45 to 60 minutes REFUELLING PROCEDURE Always refuel onto hot embers if there is insufficient burning material in the fire bed to light a new fuel charge excessive smoke emission can occur Refuelling must be carried out onto a suf...

Страница 10: ...operation the stove and all the fittings door handles and controls get very hot DO NOT OVER FIRE THE STOVE It is possible to fire the stove to such an extent that damage may occur Look out for parts of the stove or flue glowing red hot If such a situation occurs adjust the air supply accordingly to reduce the burning rate CHIMNEY FIRE In the event of a chimney fire Shut all air controls immediatel...

Страница 11: ...Should rust become apparent clean thoroughly with a wire brush and apply a suitable anti rust treatment During prolonged periods out of use the air inlets should be left open and the door left slightly ajar in order to circulate fresh air and discourage condensation from forming which could encourage corrosion FIRE ROPE Check the rope around the door and glass if rope is becoming detached replace ...

Страница 12: ...regular basis If they become worn damaged or not positioned correctly non wear parts such as the stove top and sides will be exposed to excessive heat and may be damaged Only use replacement parts recommended by the manufacturer 9 FAULT FINDING FIRE WILL NOT BURN The fuel is too wet and not suitable Air inlets to the stove are blocked The flue is blocked or restricted Inadequate air supply into th...

Страница 13: ...iency 75 4 Thermal Output 4 1 kW CO at 13 O 0 10 Mean Flue Temp 246 C Fuel Smokeless Efficiency 79 2 Thermal Output 4 5 kW CO at 13 O 0 09 Mean Flue Temp 263 C Side Wall 500mm Back Wall 600mm Hearth temp 100 C Minimum Distance from flammable materials FOLLOW THE USER S INSTRUCTIONS USE ONLY RECOMMENDED FUELS APPLIANCE IS CAPABLE OF INTERMITTENT OPERATION APPLIANCE SHOULD NOT BE INSTALLED IN A SHAR...

Страница 14: ...iency 75 6 Thermal Output 5 0kW CO at 13 O 0 12 Mean Flue Temp 282 C Fuel Smokeless Efficiency 86 5 Thermal Output 4 9 kW CO at 13 O 0 10 Mean Flue Temp 210 C Side Wall 500mm Back Wall 600mm Hearth temp 100 C Minimum Distance from flammable materials FOLLOW THE USER S INSTRUCTIONS USE ONLY RECOMMENDED FUELS APPLIANCE IS CAPABLE OF INTERMITTENT OPERATION APPLIANCE SHOULD NOT BE INSTALLED IN A SHARE...

Страница 15: ...iency 79 0 Thermal Output 8 4 kW CO at 13 O 0 10 Mean Flue Temp 312 C Fuel Smokeless Efficiency 79 6 Thermal Output 79 6 kW CO at 13 O 0 08 Mean Flue Temp 310 C Side Wall 500mm Back Wall 750mm Hearth temp 100 C Minimum Distance from flammable materials FOLLOW THE USER S INSTRUCTIONS USE ONLY RECOMMENDED FUELS APPLIANCE IS CAPABLE OF INTERMITTENT OPERATION APPLIANCE SHOULD NOT BE INSTALLED IN A SHA...