SMOKELESS ANTHRACITE RESULTS

PARAMETER

 SMALL 

MEAN

 MEDIUM 

MEAN

 LARGE 

MEAN

Total efficiency

79.2

86.5%

79.6%

Nominal heat output

4.5 kW

4.9 kW

8.0 kW

Mean CO

2

 emission

9.14

11.81%

11.20%

Mean CO emission

0.12

0.17%

0.13%

Mean CO emission (at 13 % O

2

)

0.09%

0.10%

0.08%

Mean flue gas temperature

263 ºC

210 ºC

310 ºC

Flue gas mass flow

4.1 g/s

3.2 g/s

5.9 g/s

Mean CnHm emission (at 13 % O

2

)

45 Nmg/m

3

45 Nmg/m

3

30 Nmg/m

3

Mean NOx emission (at 13 % O

2

)

140 Nmg/m

3

111 Nmg/m

3

124 Nmg/m

3

DIN Plus particulates (at 13 % O

2

)

24 Nmg/m

3

16 Nmg/m

3

18 Nmg/m

3

Please note that details and specifications contained herein are correct at the time of going to 
print. We reserve the right to change specifications at any time without prior notice.

3.  IMPORTANT INFORMATION ABOUT INSTALLING AND USING THE STOVE

 All national and local regulations, 

including those referring to national and 
European standards, need to be complied 
with when installing the stove.

 The stove must be installed by a 

registered installer or approved by your 
local building control officer.

  Only use for domestic heating purposes 

only.

  Burn only approved fuels (Wood or 

manufactured smokeless fuel). Do not 
use petroleum based products or use as 
an incinerator.

  This stove will become very hot whilst in 

operation and due care should be taken. 

  Thick gloves should be used to operate 

the primary/secondary controls or 
reaching inside the stove to position fuel 
or remove ash. 

  Do not place flammable objects on or 

near the stove.

  It is possible to fire the stove beyond its 

design capacity. This could damage the 
stove, so watch for signs of overfiring - if 
any part of the stove starts to glow red, 
the stove is in an overfire situation and the 
controls should be adjusted accordingly. 

  Never leave the stove unattended for 

long periods without first adjusting 
the controls to a safe setting. Careful air 
supply control should be exercised at all 
times.

  The stove must NOT be installed into a 

chimney that serves any other appliance 
and is suitable for intermittent burning.

  Do not make unauthorised changes or 

modifications to the stove

 The stove and chimney flue must 

be regularly cleaned. It is especially 
important to check for blockages 
following a prolonged shutdown period. 

  It is recommended that the stove and flue 

is regularly maintained by a competent 
engineer or Chimney sweep.

Содержание 141-L-SOLWAY

Страница 1: ...User Installation Manual Version 2 2020 02 22 www mi fires com BS EN 13240 2001 A2 2004 Tested as intermittent appliances burning wood logs MODEL Solway Small Solway Medium Solway Large ...

Страница 2: ...and smoke control areas 3 2 Product Specification 4 3 Important information about installing and using the stove 5 4 Unpacking Assembly 6 5 Installation of the stove 6 6 Operating Instructions 8 7 Guidance on safe operation 10 8 Maintenance 11 9 Fault Finding 12 10 CE Data plates 13 ...

Страница 3: ...y Welsh Ministers and by the Department of the Environment respectively Further information on the requirements of the Clean Air Act can be found here https www gov uk smoke control area rules Your local authority is responsible for implementing the Clean Air Act 1993 including Designation and supervision of smoke control areas and you can contact them for details of Clean Air Act requirements The...

Страница 4: ...GS Dimensions WxDxH mm 470mm max footprint exc handle x 300mm max footprint exc handle x 530mm exc flue Flue size 125mm WOOD LOGS RESULTS PARAMETER SMALL MEAN MEDIUM MEAN LARGE MEAN Total efficiency 75 4 75 6 79 6 Nominal heat output 4 1 kW 5 0 kW 8 0 kW Mean CO2 emission 7 64 9 09 11 20 Mean CO emission 0 10 0 14 0 13 Mean CO emission at 13 O2 0 10 0 12 0 10 Mean flue gas temperature 246 ºC 282 º...

Страница 5: ...ng purposes only Burn only approved fuels Wood or manufactured smokeless fuel Do not use petroleum based products or use as an incinerator This stove will become very hot whilst in operation and due care should be taken Thick gloves should be used to operate the primary secondary controls or reaching inside the stove to position fuel or remove ash Do not place flammable objects on or near the stov...

Страница 6: ...tured using the screws supplied Ensure the fireproof gasket is correctly seated in the base of the flue adaptor 2 Install the blanking plate in the rear of the stove when the normal flue exit is required If the rear mounting flue configuration is to be used the blanking plate will be fitted to the top of the stove and the flue connector to the rear panel 3 Set ashpan in position as shown as pictur...

Страница 7: ...f combustion SOLWAY MEDIUM SOLWAY LARGE 500 500 600 500 200 200 500 Minimum distance to combustible wall Floor Protector Minimum Size mm 500 500 750 500 200 200 800 Minimum distance to combustible wall Floor Protector Minimum Size mm products from an open flued appliance This can occur even if the appliance and the fan are in different rooms If mechanical extraction is unavoidable in the same room...

Страница 8: ...rning mineral fuel and secondary air when burning wood The need for de ashing the appliance more frequently when burning mineral fuel By adjusting the degree to which the primary air and air wash vents are opened good control of the combustion is being established The air wash feature when used should function to effectively keep the inside of the door glass clear of smokey deposits WARNING The te...

Страница 9: ...r door left open for long periods The stove door should never be left open when the stove is in use Under normal chimney draft conditions expect to refuel the stove every 45 to 60 minutes REFUELLING PROCEDURE Always refuel onto hot embers if there is insufficient burning material in the fire bed to light a new fuel charge excessive smoke emission can occur Refuelling must be carried out onto a suf...

Страница 10: ...operation the stove and all the fittings door handles and controls get very hot DO NOT OVER FIRE THE STOVE It is possible to fire the stove to such an extent that damage may occur Look out for parts of the stove or flue glowing red hot If such a situation occurs adjust the air supply accordingly to reduce the burning rate CHIMNEY FIRE In the event of a chimney fire Shut all air controls immediatel...

Страница 11: ...Should rust become apparent clean thoroughly with a wire brush and apply a suitable anti rust treatment During prolonged periods out of use the air inlets should be left open and the door left slightly ajar in order to circulate fresh air and discourage condensation from forming which could encourage corrosion FIRE ROPE Check the rope around the door and glass if rope is becoming detached replace ...

Страница 12: ...regular basis If they become worn damaged or not positioned correctly non wear parts such as the stove top and sides will be exposed to excessive heat and may be damaged Only use replacement parts recommended by the manufacturer 9 FAULT FINDING FIRE WILL NOT BURN The fuel is too wet and not suitable Air inlets to the stove are blocked The flue is blocked or restricted Inadequate air supply into th...

Страница 13: ...iency 75 4 Thermal Output 4 1 kW CO at 13 O 0 10 Mean Flue Temp 246 C Fuel Smokeless Efficiency 79 2 Thermal Output 4 5 kW CO at 13 O 0 09 Mean Flue Temp 263 C Side Wall 500mm Back Wall 600mm Hearth temp 100 C Minimum Distance from flammable materials FOLLOW THE USER S INSTRUCTIONS USE ONLY RECOMMENDED FUELS APPLIANCE IS CAPABLE OF INTERMITTENT OPERATION APPLIANCE SHOULD NOT BE INSTALLED IN A SHAR...

Страница 14: ...iency 75 6 Thermal Output 5 0kW CO at 13 O 0 12 Mean Flue Temp 282 C Fuel Smokeless Efficiency 86 5 Thermal Output 4 9 kW CO at 13 O 0 10 Mean Flue Temp 210 C Side Wall 500mm Back Wall 600mm Hearth temp 100 C Minimum Distance from flammable materials FOLLOW THE USER S INSTRUCTIONS USE ONLY RECOMMENDED FUELS APPLIANCE IS CAPABLE OF INTERMITTENT OPERATION APPLIANCE SHOULD NOT BE INSTALLED IN A SHARE...

Страница 15: ...iency 79 0 Thermal Output 8 4 kW CO at 13 O 0 10 Mean Flue Temp 312 C Fuel Smokeless Efficiency 79 6 Thermal Output 79 6 kW CO at 13 O 0 08 Mean Flue Temp 310 C Side Wall 500mm Back Wall 750mm Hearth temp 100 C Minimum Distance from flammable materials FOLLOW THE USER S INSTRUCTIONS USE ONLY RECOMMENDED FUELS APPLIANCE IS CAPABLE OF INTERMITTENT OPERATION APPLIANCE SHOULD NOT BE INSTALLED IN A SHA...

Страница 16: ...www mi fires com MI Flues Ltd Taymin Business Park Mitcham Road Blackpool Lancashire FY4 4QN sales mi flues com sales mi fires com ...