background image

10

The maximum amount of fuel specified 
in this manual should not be exceeded, 
overloading can cause excess smoke.
Operation with the door open can cause 
excess smoke. The appliance must not be 
operated with the appliance door left open 
except as directed in the instructions. 
Operation with the air controls or dampers 
open can cause excess smoke. The appliance 
must not be operated with air controls or 
dampers door left open except as directed 
in the instructions.

DE-ASHING THE STOVE

Before de-ashing the stove, make sure that 
all the fuel has burned out and the ashes 

has cool down, then use a brush let the ash 
fall from bed of the fire into the ash pan 
underneath. Then take out of the ashpan. If 
you have the vacuum cleaner, suck the ash 
into the vacuum cleaner directly.
If the stove is still burning when you want to 
de-ash the stove, make sure that you take a 
heat resistant glove and use special tools for 
cleaning. Brush and vacuum cleaner are not 
suitable in this case.

WARNING
Take great care when removing and 
emptying the ash pan. It may be very hot 
and still contain burning or smouldering 
embers and is a fire risk.

7.  GUIDANCE ON SAFE OPERATION

FIRE CAN BE VERY DANGEROUS

During operation, the stove and all the fittings 
(door handles and controls) get very hot.

DO NOT OVER FIRE THE STOVE.

It is possible to fire the stove to such an 
extent that damage may occur. Look out for 
parts of the stove or flue glowing red hot. If 
such a situation occurs adjust the air supply 
accordingly to reduce the burning rate.

CHIMNEY FIRE

In the event of a chimney fire:

■ 

Shut all air controls immediately

■ 

Raise the alarm and evacuate the building

■ 

Call the fire brigade

■ 

Do not re-enter the building

FUMES

If installed, operated and maintained correctly 
the stove will not emit fumes into the room 
other than occasionally very small amounts 
when re-fuelling or de-ashing.

If fumes are being emitted during normal 
operation:

■ 

Ventilate the room by opening all doors 
and windows.

■ 

Let the fire burn out

■ 

Leave the room

■ 

Check the stove, flue and chimney for 
blockages

■ 

Do not re-use the stove until the cause 
of the problem has been identified and 
rectified.

If required seek expert help.

ADVERSE WEATHER CONDITIONS

In a small number of installations, very 
occasionally in specific weather conditions 
(direction of wind) the draw of the chimney 
may be affected causing a downdraught and 
fumes to be emitted into the room. 
If this is the case the stove should not be 
used and advice sought from a professional 
flue installer who would be able to advise 
on possible solutions such as an anti-
downdraught cowl.

Содержание 141-L-SOLWAY

Страница 1: ...User Installation Manual Version 2 2020 02 22 www mi fires com BS EN 13240 2001 A2 2004 Tested as intermittent appliances burning wood logs MODEL Solway Small Solway Medium Solway Large ...

Страница 2: ...and smoke control areas 3 2 Product Specification 4 3 Important information about installing and using the stove 5 4 Unpacking Assembly 6 5 Installation of the stove 6 6 Operating Instructions 8 7 Guidance on safe operation 10 8 Maintenance 11 9 Fault Finding 12 10 CE Data plates 13 ...

Страница 3: ...y Welsh Ministers and by the Department of the Environment respectively Further information on the requirements of the Clean Air Act can be found here https www gov uk smoke control area rules Your local authority is responsible for implementing the Clean Air Act 1993 including Designation and supervision of smoke control areas and you can contact them for details of Clean Air Act requirements The...

Страница 4: ...GS Dimensions WxDxH mm 470mm max footprint exc handle x 300mm max footprint exc handle x 530mm exc flue Flue size 125mm WOOD LOGS RESULTS PARAMETER SMALL MEAN MEDIUM MEAN LARGE MEAN Total efficiency 75 4 75 6 79 6 Nominal heat output 4 1 kW 5 0 kW 8 0 kW Mean CO2 emission 7 64 9 09 11 20 Mean CO emission 0 10 0 14 0 13 Mean CO emission at 13 O2 0 10 0 12 0 10 Mean flue gas temperature 246 ºC 282 º...

Страница 5: ...ng purposes only Burn only approved fuels Wood or manufactured smokeless fuel Do not use petroleum based products or use as an incinerator This stove will become very hot whilst in operation and due care should be taken Thick gloves should be used to operate the primary secondary controls or reaching inside the stove to position fuel or remove ash Do not place flammable objects on or near the stov...

Страница 6: ...tured using the screws supplied Ensure the fireproof gasket is correctly seated in the base of the flue adaptor 2 Install the blanking plate in the rear of the stove when the normal flue exit is required If the rear mounting flue configuration is to be used the blanking plate will be fitted to the top of the stove and the flue connector to the rear panel 3 Set ashpan in position as shown as pictur...

Страница 7: ...f combustion SOLWAY MEDIUM SOLWAY LARGE 500 500 600 500 200 200 500 Minimum distance to combustible wall Floor Protector Minimum Size mm 500 500 750 500 200 200 800 Minimum distance to combustible wall Floor Protector Minimum Size mm products from an open flued appliance This can occur even if the appliance and the fan are in different rooms If mechanical extraction is unavoidable in the same room...

Страница 8: ...rning mineral fuel and secondary air when burning wood The need for de ashing the appliance more frequently when burning mineral fuel By adjusting the degree to which the primary air and air wash vents are opened good control of the combustion is being established The air wash feature when used should function to effectively keep the inside of the door glass clear of smokey deposits WARNING The te...

Страница 9: ...r door left open for long periods The stove door should never be left open when the stove is in use Under normal chimney draft conditions expect to refuel the stove every 45 to 60 minutes REFUELLING PROCEDURE Always refuel onto hot embers if there is insufficient burning material in the fire bed to light a new fuel charge excessive smoke emission can occur Refuelling must be carried out onto a suf...

Страница 10: ...operation the stove and all the fittings door handles and controls get very hot DO NOT OVER FIRE THE STOVE It is possible to fire the stove to such an extent that damage may occur Look out for parts of the stove or flue glowing red hot If such a situation occurs adjust the air supply accordingly to reduce the burning rate CHIMNEY FIRE In the event of a chimney fire Shut all air controls immediatel...

Страница 11: ...Should rust become apparent clean thoroughly with a wire brush and apply a suitable anti rust treatment During prolonged periods out of use the air inlets should be left open and the door left slightly ajar in order to circulate fresh air and discourage condensation from forming which could encourage corrosion FIRE ROPE Check the rope around the door and glass if rope is becoming detached replace ...

Страница 12: ...regular basis If they become worn damaged or not positioned correctly non wear parts such as the stove top and sides will be exposed to excessive heat and may be damaged Only use replacement parts recommended by the manufacturer 9 FAULT FINDING FIRE WILL NOT BURN The fuel is too wet and not suitable Air inlets to the stove are blocked The flue is blocked or restricted Inadequate air supply into th...

Страница 13: ...iency 75 4 Thermal Output 4 1 kW CO at 13 O 0 10 Mean Flue Temp 246 C Fuel Smokeless Efficiency 79 2 Thermal Output 4 5 kW CO at 13 O 0 09 Mean Flue Temp 263 C Side Wall 500mm Back Wall 600mm Hearth temp 100 C Minimum Distance from flammable materials FOLLOW THE USER S INSTRUCTIONS USE ONLY RECOMMENDED FUELS APPLIANCE IS CAPABLE OF INTERMITTENT OPERATION APPLIANCE SHOULD NOT BE INSTALLED IN A SHAR...

Страница 14: ...iency 75 6 Thermal Output 5 0kW CO at 13 O 0 12 Mean Flue Temp 282 C Fuel Smokeless Efficiency 86 5 Thermal Output 4 9 kW CO at 13 O 0 10 Mean Flue Temp 210 C Side Wall 500mm Back Wall 600mm Hearth temp 100 C Minimum Distance from flammable materials FOLLOW THE USER S INSTRUCTIONS USE ONLY RECOMMENDED FUELS APPLIANCE IS CAPABLE OF INTERMITTENT OPERATION APPLIANCE SHOULD NOT BE INSTALLED IN A SHARE...

Страница 15: ...iency 79 0 Thermal Output 8 4 kW CO at 13 O 0 10 Mean Flue Temp 312 C Fuel Smokeless Efficiency 79 6 Thermal Output 79 6 kW CO at 13 O 0 08 Mean Flue Temp 310 C Side Wall 500mm Back Wall 750mm Hearth temp 100 C Minimum Distance from flammable materials FOLLOW THE USER S INSTRUCTIONS USE ONLY RECOMMENDED FUELS APPLIANCE IS CAPABLE OF INTERMITTENT OPERATION APPLIANCE SHOULD NOT BE INSTALLED IN A SHA...

Страница 16: ...www mi fires com MI Flues Ltd Taymin Business Park Mitcham Road Blackpool Lancashire FY4 4QN sales mi flues com sales mi fires com ...