11
70D0004
TPB Series Log Set
FLOOR CLEARANCES
The gas log heater must be installed at least 1
C\,
" above
any combustible flooring material, such as carpeting or
tile, which is closer than 14" to the base of the fireplace.
The minimum distance must be maintained from the top
surface of carpeting, tile, etc.
Figure 11
OR
The gas log heater may be installed nearer to the floor if a
minimum of 14" of noncombustible material such as slate
or marble is installed between the base of the fireplace and
the combustible flooring.
Figure 12
1
3
/
8
" M i n i m u m
FP2003
min clear comb floor
14" M i n i m u m
FP2004
min clear nocomb floor
Heater in
Fireplace or
Firebox
Combustible
Material
FP003
Figure 11 -
Minimum Clearance above Combustible Flooring
Heater in
Fireplace or
Firebox
Combustible
Material
This Distance May Now be Less
Than 1
C\,
"
FP004
Figure 12 -
Minimum Clearance above Combustible Flooring with
Noncombustible Material Installed at Base of Fireplace