MHSC SB44SS Скачать руководство пользователя страница 10

SB44SS Outdoor Woodburning Fireplace

10

87D0059

INSTaLLaTION preparaTION 

Figure 8

8’ 0” 

Level 

FP1880 
install prep 
8/08 

Joist - Insulate 
Same as Ceiling

Refer to Notes

Firestop Spacer

Solid 
Surface

Chimney Cap

Flat Chase 
Top Flashing

Chimney 
Section

Insulate Outside 
Walls of Chase

Solid Continuous 
Surface

Insulation
(Thermal Barriers)

Outside Base

FP1880

NOTeS:

1.  Firestop spacer must be used.
.  Local codes may not require firestop-

ping at the ceiling level for chase in-
stallation, but it is recommended for 
safety and reducing heat loss.

3.  Do not insulate the chase with blown 

or  fill  type  insulation.  Insulation 
should  only  contact  the  fireplace  at 
points where the fireplace would nor-
mally be contacted by framing mate-
rials.

Survey the planned location for the fireplace for overhead plumbing or electrical wires, etc., that might 
complicate the installation or endanger persons installing or cleaning the chimney.  Avoid a location 
where the chimney cap will be near abrupt changes in the roof shape, nearby wall or embankments, 
under or near trees or above the roof of a single story wing of a two story building. 

Figure 10.

  All 

these conditions can cause turbulence or pressure conditions that can cause poor chimney draft 
and smoke spillage from the fireplace opening.  Elbows may be used to offset the chimney to avoid 
obstructions or to locate the chimney cap in a preferred location. Refer to the sections of this manual 
pertaining to chimney offsets for instructions on proper elbow use.  Poor installation or location of 
the chimney cap and/or components can cause wind blown rain to enter the chimney.
Be sure the selected location will allow a 17” square combustible material-free space for the chimney 
to pass through.  If the chimney is to pass through living or storage spaces, be sure there is adequate 
space to enclose the chimney to avoid personal contact with, or damage to, the chimney.  If the 
fireplace is to be installed on an outside wall, the surrounding walls (chase) should be constructed 
and insulated as shown by 

Figure 6

.  Failure to insulate the fireplace form outside temperatures will 

cause heat loss through and around the fireplace.

Содержание SB44SS

Страница 1: ...or Fireplace Model SB44SS 539026 SB5400 cover Safety Notice If this appliance is not properly installed operated and main tained a house fire may result To reduce the risk of fire follow the installat...

Страница 2: ...his or any other factory built fireplace properly can result in a house fire or other occurrences that could cause deaths injuries and property damages It is very important that the persons installing...

Страница 3: ...t or other prod ucts not specified for use with this fireplace Warning Do not pack required air spaces with combustible material or insulation not specifically recommended for use in such areas Propos...

Страница 4: ...fireplace is designed to sit directly on a combustible floor The fireplace must be installed with clearances to combustible building materials specified in this manual Only parts manufactured by MHSC...

Страница 5: ...up to open or pulling down to close the damper When the fireplace is not in use the damper should be closed to prevent cold air form entering the chimney as well as preventing warm air in the room fro...

Страница 6: ...356 456O 456O 856QE 27 1156QE 6 6 1 8 3556QE 52 6 10 6QE 8 6 11 6 155 6 O 539028 SB5400SS dims 11 ID Flue 13 OD Outer Pipe Gas Line Opening Outside Air Opening A B C FP1531 hearth dimensions 9 04 djt...

Страница 7: ...stibles Flexible Duct Type FP 4 U Combustion Air Assembly FP2236 Nail to Framing Members Galvanized Metal Strip CAUTION Do not restirict side air inlet vents with sur round or trim materials Storm Col...

Страница 8: ...igure 4 12 Max M1002 Mantel install 8 08 Mantel Installation Combustible Framing Members to Top of Spacers Combustible Mantel Top Edge of Fireplace 18 Min From Fireplace Opening to Bottom of Combustib...

Страница 9: ...tral heat outlets or returns or other places where air movements may disturb the airflow around the fireplace Air turbulence near the fireplace may cause smoke to spill out of the fireplace opening 64...

Страница 10: ...hanges in the roof shape nearby wall or embankments under or near trees or above the roof of a single story wing of a two story building Figure 10 All these conditions can cause turbulence or pressure...

Страница 11: ...Spacer FP1883 Insulating Fireplace Enclosure for Cold Climates If you live in a cold climate it is not required but highly recommended that you insulate the fireplace enclosure to eliminate cold air...

Страница 12: ...n it and insulating qualities equal to or better than the 1 2 covering provided by the H2068 Figure 12 Figure 13 Hearth Safety Strip is Required When Unit is Placed on a Combustible Floor or Platform...

Страница 13: ...he crack from developing the hearth extension materials must be firmly fastened in place Wall ties should be screwed to the face of the fireplace and imbedded in the mortar joints of brick stone or ot...

Страница 14: ...stallations RLTCF11L Extended chimney cap for contemporary installations 8 6 12 0 6 12 pitch flashing for contemporary installation 8 12 12 6 12 to 12 12 pitch flashing for contemporary installation F...

Страница 15: ...require electrically grounding the fireplace and chimney Chimney Installation In order to assure safe and satisfactory performance of the fireplace it is very important to properly install the chimne...

Страница 16: ...ress down until the snap locks engage Continue the process adding the chimney sections on top of each other until the chimney is at least six inches above the roof opening on all sided As the chimney...

Страница 17: ...Securely to Lower pipes Before Fastening Support Straps FP1890 FP 548b SHR 5 11 99 djt Angle of Chimney at Ceiling Size of Chimney Vertical 30 11 CF 2 Wall FS2A 1756O x 1756O 445 x 445 mm FS6A 17 6 x...

Страница 18: ...two inch minimum air space clearance to the chimney at the extremities of the offset It is recommended that enclosing material not follow the inclined portions of the chimney Offset Installation Sequ...

Страница 19: ...ra tion above A Height of the chimney is measured from the hearth to the chimney exit Max 86 0 Min 0 Elbows 18 0 2 Elbows 24 0 4 Elbows 30 0 B Do not use more than 4 elbows per chim ney Attach the str...

Страница 20: ...imney Enclosure Chimney Must Be Enclosed in Accessible Areas Firestop Spacer Diagonal Chimney Enclosure RISE Firestop Spacer 2 Air Space Clearance to Combustibles NOTE Four 4 elbows may be used when t...

Страница 21: ...uct in place and slide the flashing over the chimney Adjust the chimney to assure that the proper minimum clearances are maintained 5 Nail the flashing securely in place with eight nails 6 Seal the cr...

Страница 22: ...ould be at least 24 inches apart to help prevent smoke from a fireplace in use from being drawn down the chimney of a fireplace that is not in use Additional spacing between caps or staggering the hei...

Страница 23: ...rting collar to left side of fire place with four 4 sheet metal screws provided NOTE The starting collar extends through the outer fireplace jacket and will seal against the firebox wall when secured...

Страница 24: ...gasoline might be drawn into the fireplace 4 Combustion air can be drawn form the crawl space under a house when an adequate supply of air is provided by open ventilation 5 Do not take combustion air...

Страница 25: ...st three inches beyond the face of the wall to which the AK 4 inlet air vent will be attached The duct may be cut with a standard pocket knife use FP 4 U duct for maximum efficiency and safety Do not...

Страница 26: ...eplace When an approved ANSI Z21 11 2 unvented room heater is installed in this fireplace an H2853 CANOPY must also be installed Warning Do not operate an unvented gas log set in this fireplace with t...

Страница 27: ...the supporting floor will further reduce the possibility of such a crack developing Wall ties should be fastened to the face of the fireplace with sheet metal screws and placed in the mortar joints of...

Страница 28: ...any trim materials to extend closer than 3 8 inch to the vertical edges of the firebox opening if glass doors are to be installed Use Only Noncombustible Materials Below Top of Spacers Fireplace Face...

Страница 29: ...wood is generally more expensive but a little combined with other wood goes a long way Start your fire with a mixture of softwood and hardwood then add some fruit or nut wood for nostalgic aroma Since...

Страница 30: ...he fireplace is equipped with glass doors close them DO NOT LEAVE CHILDREN OR PHYSICALLY OR MENTALLY HANDICAPPED OR SENILE PERSONS ALONE WITH A BURNING FIREPLACE You ll need a minimum of three logs pr...

Страница 31: ...ng the heating season to determine if a creosote buildup has occurred If creosote has accumulated it should be removed to reduce the risk of a chimney fire The chimney cap can be removed for inspectio...

Страница 32: ...ial and parts for the installation of the fireplace 3 Do insulate the exterior walls surrounding the fireplace to prevent excessive heat loss from the fireplace 4 Do trim the face of the fireplace onl...

Страница 33: ...flashing roof 14 Don t dry clothing or other articles near the fireplace 15 Don t store or place flammable liquids gases or pressurized containers near the fireplace 16 Don t neglect to instruct all r...

Страница 34: ...t and accurate service please provide the following information when placing a repair part order Model number of your Appliance Part Name Part Number and Quantity of parts needed Technical Service Dep...

Страница 35: ...this fireplace before you purchase it Blowers or fans which are warranted separately Heat loss due to the passage of heat or air through or around the fireplace Also under our five year coverage we do...

Страница 36: ...MHSC 149 Cleveland Drive Paris Kentucky 40361 www mhsc com...

Отзывы: