MHSC B36LA8 Скачать руководство пользователя страница 25

87D0176

25

B36LA8 & B36RA8 Woodburning Fireplaces

GAS APPLIANCE INSTALLATION

WARNING:

    Improper  installation  or  operation  of  a  gas 

appliance in this fireplace can allow unburned gas to leak 
out which will cause a fire or explosion hazard, or the re-
lease  of  poisonous  carbon  monoxide  into  the  dwelling 
which can cause serious injury or death to its inhabitants.  
To reduce these risks to a minimum, the following impor-
tant notices and instructions should be read and followed 
carefully.

IMPORTANT NOTICES:

  

1.  The provision for a gas line is intended for connection 

to a decorative gas appliance which and complies with 
the Standard for Decorative Gas Appliances for Instal-
lation in Vented Fireplaces, ANSIZ21.60.   If a deco-
rative  gas  appliance  is  installed,  it  must  be  installed 
in accordance with the National Fuel Gas Code, AN-
SIZ223.1.  

 

CAUTION:

  “When a decorative gas appliance  is in-

stalled, the fireplace damper must be fixed in a man-
ner which will maintain the minimum permanent vent 
opening at all times.”        

 

WARNING:

  This fireplace has not been tested with an 

unvented gas log set. To reduce risk of fire or injury, do 
not install an unvented gas log set into fireplace.

  The installer of the fireplace and gas appliance must 

describe the operation of the fireplace and appliance 
to  the  people  who  will  be  operating  them  and  leave 
all instruction manuals with the operator of the appli-
ance.

2.  An approved gas shut off valve must be located out-

side the fireplace in an area accessible to the users of 
the fireplace.

3.  All gas piping and fitting must be either steel or mal-

leable iron.  

4.  Some code authorities prohibit or place restrictions on 

the use of gas appliances in fireplaces.  Check with lo-
cal code authorities before proceeding with the instal-
lation.

5.  The gas appliance and all connecting gas piping should 

only be installed by a licensed gas appliance installer.  
Refer to 

Page 14, Figure 11

 for the gas line opening 

dimensions on the fireplace.

The following instructions only apply to passing the gas 
line  through  the  fireplace  wall.    Follow  the  instructions 
provided by the appliance for the gas line, testing and ad-
justing it.
1.  Remove  the  side  brick  form  the  fireplace  and  locate 

the dimple “B” referred to by 

Figure 29

.

2.  Tap out a round hole in the brick liner with a hammer 

by tapping lightly on the recessed area.

3.  Remove the two screws that hold the cover plate on 

the jacket wrap and discard the cover plate.

4.  Use a screwdriver or similar tool to push the loose in-

sulation  out  of  the  tube  between  the  firebox  and  the 
outer jacket of the fireplace.

5.  Install the gas pipe through the tube between the fire-

box and jacket.

6.  Attach the gas appliance to the gas pipe according to 

the instructions provided with the gas appliance.

7.  Pack the insulation removed in Step 4 around the pipe 

to prevent air flowing through the tube either into or out 
of the firebox.

8.  Be sure the gas is turned off at the appliance, then turn 

the gas on at the cut off valve and test the gas line con-
nections for leaks with soapy water solution or a liquid 
leak detector.  DO NOT USE A MATCH OR OTHER 
FLAME SOURCE TO CHECK FOR GAS LEAKS.  If a 
gas leak is detected, turn the gas off immediately and 
fix the leak.

9.  Proceed with installation and adjustment of the gaas 

appliance as directed by the instructions provided with 
the gas appliance. If a gas leak is detected, turn the 
gas off immediately and fix the leak.

FP2174
gas line installation 
12/08

CAUTION:

  When  using 

a  gas  appliance,  the  fire-
place damper must be set 
in fully open position.

Figure 29 - 
Installation of Gas Appliance in Fireplace

Outer Fireplace Wrap

Inner Fireplace Wrap

Side Brick

26” Max.

Fireplace Firebrick

Hearth Brick

Gas Line Access Tube

Repack Insulation Around Gas Line 
Where it Passes Through Gas Line 
Access Tube for Proper Seal

Maintain 1/2” 

Minimum Air 

Space Clearance 

to Combustibles 

for Gas Line Out 

to 4” From Side of 

the Fireplace

Combustible 
Materials May 
Be Located at 
Zero Clear-
ance to Gas 
Line Beyond 4” 
From Fireplace 
Side.

Back Refractory 
Brick

Side Refractory 
Brick

Dimple

FP2344
gas line

Содержание B36LA8

Страница 1: ...r Residential Installation 36 Built in Wood Burning Corner Fireplace with Optional Outside Air and Glass Doors WARNING This fireplace has not been tested with an unvented gas log set To reduce risk of...

Страница 2: ...installation you should check with local building officials to obtain required permits and assure compliance with local regulations and coded If you encounter problems with code requirements contact...

Страница 3: ...ed for supplemental heating only and is not intended for use as a primary heating system The fireplace is designed to sit directly on a combustible floor The fireplace must be installed with clearance...

Страница 4: ...the precautions and recommendations in the section of this manual pertaining to outside combustion air assembly The fireplace is also equipped with a flue damper which must be open when the fireplace...

Страница 5: ...provides for the installation of the model LF FS 2 firestop spacer in a residential installation Since the pitch of the roof influences the opening size required at the roof level table 1 should be u...

Страница 6: ...himney 1Z x Min Air space Clear ance to Combustibles Chimney Section SK81 1 ft pipe SK818 18 pipe SK83 3 ft pipe SK84 4 ft pipe Top Spacer Zero Clearance to Combustibles at Side Spacers Glass Doors Mo...

Страница 7: ...Model I658 Clearance from Fireplace Opening to Sidewall When Wall Shield is not Used B36RA8 Hearth Extension Model I627 Hearth Extension Model I658 Minimum Clearance from Fireplace Opening to Sidewal...

Страница 8: ...hearth extension and the face of the fireplace To help prevent the crack from developing the hearth extension materials must be firmly fastened in place Wall ties should be screwed to the face of the...

Страница 9: ...yramid style chimney cap used to terminate chimney through a chase Includes adapter Flashing not included CF8CA Adapter kit Unites square termination with chimney pipe 202036 Housing extensions Extend...

Страница 10: ...3 Min Storm Collar Flashing Roof Joist Shields Attic Space Refer to Table 1 for Roof Opening Size FS Firestop Spacer 14Z x x 14Z x Framed Opening 1Z x Clearance to Com bustibles with Firestop SK8 Seri...

Страница 11: ...tional for cold climate not a requirement for unit op eration Termination Cap Storm Collar Pan Flashing Draftstop Top Spacer Surround Screen Firebox Metal Safety Strips 1 2 or 3 pieces Nailing Flange...

Страница 12: ...oist 1Z x Clear ance to Combus tibles When Using Firestop Max Installation Height 86 14Z x Square Hole in Joist 1Z x Min Air Space Clear ance Between Chimney and combustibles Firestop Spacer Firestop...

Страница 13: ...arances as specified by this in struction manual 3 Set the fireplace in the desired location and be sure it is securely supported and leveled Install metal safety strip for hearth extension as shown b...

Страница 14: ...eplace Model C36RMA B36RA8 with RLK Louver kit WB36LR Glass Door and OAC6 Combustion Air Model C36LMA not shown same as above except uses LLK Louver Kit on the B36LA8 fireplace Cool Air Inlet WB36LR G...

Страница 15: ...ge to the chimney 4 Install firestop spacers at each ceiling level 5 Install the proper chimney cap or chimney housing on the chimney to prevent the entry of rain and debris into the chimney and to as...

Страница 16: ...to the chimney exit B36LA8 B36RA8 Maximum 90 0 Minimum Without Elbows 15 6 With 2 Elbows 17 6 With 4 Elbows 21 0 B Do not use more than 4 elbows per chimney Attach the straps of the return top elbow t...

Страница 17: ...lace may be used 6 A guy wire stabilizer is required for chimneys extend ing more than 6 1 8 m above a roof line The Ten Foot Rule Major U S building codes specify a minimum chimney height above the r...

Страница 18: ...hase it is also a good idea to install a firestop at the first ceiling level above the fireplace and enclose the chase with sheeting material Insulation may then be installed above sheet ing material...

Страница 19: ...size of the hole in ceiling will vary with the angle at which the chimney passes through ceiling Drive a nail up through ceiling at marked chimney center point Go to floor above and see where hole wil...

Страница 20: ...is used to keep pipe spaced properly and required for safety Nail the firestop spacer at each corner to the framing members of the ceiling hole Note A firestop spacer is not required at the roof Hole...

Страница 21: ...chimney termina tion installed Refer to installation instructions provided with the chimney termination to find correct size of roof hole There must be an air space 1 38 mm with SK8 between outermost...

Страница 22: ...E Firestop Spacer 14Z x x 14Z x Maximum four 4 elbows Per Fire place Offset Max 10 Support Straps Diagonal Chimney Enclosure Vertical Chimney Enclosure Recommended Diagonal Chimney Enclosure Acceptabl...

Страница 23: ...an exterior location which is not likely to be accidentally blocked in any manner The assembly should be located above the snow line to prevent blockage by snow accumulation 3 The combustion air inlet...

Страница 24: ...e fireplace with the four 4 sheet metal screws provided Figure 24 3 Cut a 6 diameter opening for model OAC4 in the out side wall covering where the model OAC4 outside grille is to be located Figure 26...

Страница 25: ...sions on the fireplace The following instructions only apply to passing the gas line through the fireplace wall Follow the instructions provided by the appliance for the gas line testing and ad justin...

Страница 26: ...is manual Page 13 Figure 10 Combustible mantels and trim must be installed in accordance with the National Fire Protection Association ANSI NFPA 211 Standard Section 7 2 3 3 Glass Door Installation Th...

Страница 27: ...rer Recommendation Top Edge of Fireplace Opening Mantel Installation Do Not Install Combustible Facing Material Below Top Edge of Fireplace Air Inlet Opening CAUTION Never block bottom air inlet openi...

Страница 28: ...blems If your fireplace is equipped with an outside combustion air assembly open the combustion air inlet by pushing upward on the lever located above the firebrick on the left side of the firebox NEV...

Страница 29: ...ced on a noncombustible floor or on the ground well away from all combustible materials pending final disposal If the ashes are disposed of by burial in soil or otherwise locally dispersed they should...

Страница 30: ...the chimney 9 Do install firestop spacers at each ceiling level when the chimney is installed in a multistory building 10 Do install the proper chimney cap or chimney housing on the chimney to preven...

Страница 31: ...larly 21 Don t operate the fireplace with the glass fire screen doors partially open The doors should always be fully open or fully closed 22 Don t use gasoline kerosene engine oil or charcoal lighte...

Страница 32: ...Y 40361 www mhsc com Item Description Qty B36RA8 B36LA8 1 Retainer Side Brick 1 020270 020270 2 Retainer 2 Z19901 Z19901 3a Firebrick Side Assy Right 1 014012 3b Firebrick Side Assy Left 1 021663 4 Ro...

Страница 33: ...87D0176 33 B36LA8 B36RA8 Woodburning Fireplaces...

Страница 34: ...34 87D0176 B36LA8 B36RA8 Woodburning Fireplaces...

Страница 35: ...your local building code contains restrictions on the use of this fireplace before you purchase it Blowers or fans which are warranted separately Heat loss due to the passage of heat or air through o...

Страница 36: ...MHSC 149 Cleveland Drive Paris Kentucky 40361 www mhsc com...

Отзывы: