B36LA8 & B36RA8 Woodburning Fireplaces
FIREPLACE INSTALLATION
Figure 5
39”
6” Min.
FP2162
brick or stone hearth extension
Fireplace
Hearth
Do Not Block Air
Inlet Openings
Safety Strip Required
When Unit is Placed on
Combustible Floor or
Platform
58” or 54” if Wall
Shield is Used
FP2162
Alternate Brick or Stone Hearth Ex-
tensions for use with the B36LA8,
& B36RA8 Fireplace
&0
3INGLESTORYINSTALL
Figure 6
Single Story Installation
with Attic Space
Chimney Cap
3’ Min.
Storm Collar
Flashing
Roof Joist
Shields
Attic Space
Refer to Table
1 for Roof
Opening Size
FS Firestop Spacer 14
Z\x
”
x 14
Z\x
” Framed Opening
1
Z\x
” Clearance to Com-
bustibles with Firestop
“SK8” Series Chimney
1
Z\x
” Min. Air Space
Clearance Between
Combustibles and
Chimney
13’ Min.
FP2163
&0
SHIELDINSTALL
Figure 7
Installation of Shields with MHSC End Open Fireplace
and “SK8” Series Chimney
Roof Joists Shields - Secure to Top of Chase Top
Opening Before the Chase Top Flashing is Installed
14
Z\x
” Min.
Chase Top Installation
14
Z\x
” Min.
Secure Shields to
the Roof as shown
Before Installing the
Roof flashing on a
Conventional Roof
Conventional Roof Installation
FP2164