GENERAL SAFETY WARNINGS AND PRECAUTIONS

CAUTION! - Never power up the motor before fully installed
on the column and leaf of the gate.

• During installation, handle the automation with care, avoiding the risk of

impact, dropping or contact with any type of liquid. Never place the
product near to sources of heat and never expose to naked flames. This
may damage product components and cause malfunctions, fire or haz-
ardous situations. If this occurs, suspend installation immediately and
contact the MhouseTechnical Assistance.

• Never make modifications to any part of the product. Operations other

than as specified can only cause malfunctions. The manufacturer
declines all liability for damage caused by makeshift modifications to the
product.

• If the power cable is damaged, it must be replaced exclusively by a

qualified technician, to avoid potential risks.

• Connect the control unit to an electric power line equipped with an

earthing system.

• This product is not designed to be used by persons (including children)

whose physical, sensorial or mental capacities are reduced, or with lack
of experience or skill, unless suitable instructions regarding use of the
product have been provided by a person responsible for safety.

• The key-operated selector switch must be positioned in sight of the

automation, but far from moving parts and at a height of at least 1.5 m
from the ground, not accessible by the public. If this is used in “hold-to-
run” mode, ensure that there are no persons in the vicinity of the
automation.

• In the vicinity of the automation children must be supervised to ensure

that they do not play with it.

• Ensure that there are not points of entrapment or crushing with fixed

parts when the gate leaf is in the maximum opening or closing position;
protect parts if necessary.

• The product may not be considered an efficient system of protection

against intrusion. If an efficient protection system is required, the
automation must be integrated with other safety devices.

• The automation must not be used before performing the commissioning

procedure as specified in the chapter “Testing and commissioning”.

• Check the automation frequently to ensure there is no imbalance, signs

of wear or damage to electrical or mechanical parts. Do not use the
automation if adjustments or repairs are necessary.

• In the event of long periods of disuse, to avoid the risk of leaks of harm-

ful substances from the optional battery (PR1) disconnect it from the
automation and store in a dry location.

• Do not allow children to play with fixed control devices. Keep remote

control devices out of reach of children.

• The product’s packaging materials must be disposed of in full compli-

ance with local regulations.

Operation warnings

• For cleaning the product surfaces, use a soft damp cloth. Use water

only; never use detergents or solvents for cleaning.

–––  STEP 1  –––

Safety warnings

• CAUTION!

– This manual contains important instructions and

warnings for personal safety.

Incorrect installation could cause seri-

ous physical injury. Carefully read all parts of this manual before starting
any work. If in doubt, suspend installation immediately and contact the
Mhouse Technical Assistance.

• CAUTION!

– Important instructions: keep this manual in a safe

place to enable future product maintenance and disposal proce-
dures.

• CAUTION!

– According to the most recent European legislation,

the production of a power-operated door or gate must comply with
the standards envisaged in the Directive 2006/42/EC (Machinery
Directive) and in particular standards EN 12445; EN 12453; EN
12635 and EN 13241-1, which enable declaration of presumed
conformity of the automation. 

In consideration of this

, all mains

connection, testing, commissioning and maintenance operations
must be performed exclusively by a qualified and skilled techni-
cian

.

All preliminary set-up, installation and programming operations
may be performed by personnel with standard skills, provided that
all instructions and the relative sequences in this manual are strict-
ly observed, with particular reference to the warnings in this STEP
1.

Installation warnings

While reading this manual, take care to observe all instructions
marked with the following symbol:

These symbols indicate subjects that may be the source of potential
hazards and therefore the prescribed operations must be performed
exclusively by qualified and skilled personnel, in observance of
these instructions current safety standards.

• Before installation, ensure that this product is suitable for automation of

your gate or door (see STEP 3 and chapter “Product Technical Specifi-
cations”). If not suitable, do NOT proceed with installation.

• On the system power mains install a device for disconnection (not sup-

plied), to guarantee a gap between contacts and complete disconnec-
tion in the conditions of overvoltage category III.

All installation and maintenance operations must be performed
with the automation disconnected from the power supply.

If the

power disconnect device is not visible from the location of the automa-
tion, before work a notice should be affixed on the disconnect device,
with the text “CAUTION! MAINTENANCE IN PROGRESS”.

KNOWLEDGE OF THE PRODUCT AND PREPARATION FOR INSTALLATION

–––  STEP 2  –––

2.1

- PRODUCT DESCRIPTION AND INTENDED USE

The devices in this kit, plus other accessories (some optional and not
included in the pack), form the automation system named “WG20S”,
designed for the automation of a “residential” swing gate. 

Any other use

than as specified herein or in environmental conditions other than as
stated in this manual is to be considered improper and is strictly pro-
hibited!

The main part of the automation comprises one control unit and two
electromechanical gearmotors, each equipped with a 24 V DC motor, a
worm reducer and a mechanical locking system with key to enable manu-
al opening and closing of the gate in the event of a power failure. 
The control unit comprises a board and incorporated radio receiver which
receives the commands sent by the user via a transmitter. It can memo-
rise up to 256 GTX4 transmitters (if memorised in “Mode I”) and up to 6
pairs of PH100 photocells.

NOTES TO MANUAL

• This manual describes how to set up a complete and optimal

automation, such as that shown in fig. 6, using all Mhouse devices
that are part of the automation system named “WG20S”. Some of
these devices are optional and may not be present in the kit. For a
complete overview of the devices, refer to the MHouse product
catalogue.

• This manual has been drawn up as a step-by-step guide. There-

fore, to ensure safe and facilitated assembly and programming
procedures, perform all operations described in the same order as
specified in this document.

Содержание WG10SK

Страница 1: ...MhouseKit WG20S For power operated swing gate Installation instructions and warnings and User Manual IS0010A00EN_28 03 2011...

Страница 2: ......

Страница 3: ...20S 7 PROGRAMMING STEP 7 13 7 1 POWER SUPPLY CONNECTION 13 7 2 INITIAL CHECKS 13 7 3 LEARNING CONNECTED DEVICES 13 7 4 LEARNING THE GATE LEAF OPENING AND CLOSING ANGLES 13 7 5 CHECKING THE RADIO TRANS...

Страница 4: ...place to enable future product maintenance and disposal proce dures CAUTION According to the most recent European legislation the production of a power operated door or gate must comply with the stan...

Страница 5: ...e TX and one RX D 2 GTX4 radio transmitters E 1 FL100 flashing light with integrated aerial F 1 control unit CL20S G Metal hardware Notes Some devices and accessories specified in the manual are optio...

Страница 6: ...aceways for electric cable ducting 4 1 3 Ensure all equipment and materials for work are available Before starting work ensure that you have all equipment and materials required to complete the work E...

Страница 7: ...English 5 English 2 3 4 5 GRAPH 2 1 B F D C A G E maximum leaf length m Maximum leaf weight kg...

Страница 8: ...nt plate as shown in fig 11 07 Remove the rear cover of the gearmotors pulling it out in the direction of the arrows fig 12 08 Move the leafs to the closed position 09 With reference to the previously...

Страница 9: ...ee the two options in fig 29 2 05 Fix the base using the relative screws B of fig 29 3 ensuring that the hole on the base C of fig 29 3 is aligned with the cable outlet 2 self tapping screws are also...

Страница 10: ...8 English English 8 9 11 12 13 14 15 10...

Страница 11: ...English 9 English 16 17 18 19 20 B A C D E F G H 21 22 23...

Страница 12: ...TX RX 24 25 26 Blue Brown Yellow Green 28 C B PH100 FL100 KS100 WG10SK M2 WG10SK M1 Brown Yellow Green Blue Blue Yellow Green Brown A B 27 10 English English...

Страница 13: ...English 11 English 30 A B 6 mm x4 A B A B A B B B B 1 2 3 4 1 2 3 4 5 29 6 B C A D E F...

Страница 14: ...12 English English 30 A B A B A B A B A B A B 5 6 7 8 9 11 12 10 A B A B 6 mm x4 A A A A 4...

Страница 15: ...ion for example if a photocell is added simply repeat the procedure from point 01 7 4 LEARNING THE GATE LEAF OPENING AND CLOSING ANGLES After learning devices the control unit must recognise the openi...

Страница 16: ...14 English English 31 A B 32 A C B 33 35 A B A B 34 T1 T2 T3 T4...

Страница 17: ...d Separate the waste into categories for disposal according to the methods envisaged by current legislation in your area or return the product to the retailer when purchasing a new version Caution Loc...

Страница 18: ...T1 three times Press T1 four times Press T2 once Press T2 twice Press T2 three times Press T2 four times Press T3 once Press T3 twice Press T3 three times Press T4 four times Press T4 once Press T4 tw...

Страница 19: ...ts to flash 05 Count the number of flashes and according to the number check the corresponding value on Table 3 Example After pressing T1 and T2 for 5 s followed by T1 if the flashing light flashes th...

Страница 20: ...m number of cycles per day performed by the automation in a certain period of the year provided that a positive energy balance is maintained The first step in calculating the energy available is dealt...

Страница 21: ...ECSBus ECSBus is a system that enables connections of ECSBus devices using just two wires which convey both electrical power and communication signals All devices are connected in parallel on the sam...

Страница 22: ...de 2 occupies one unit per key Caution As memorisation procedures have a time limit 10 s it is important to read the instructions in the next paragraphs before starting Key T1 OPEN Command Key T2 Pede...

Страница 23: ...es quickly for a number of times equal to the command selected 04 Within 10 s press the required key on the radio transmitter for at least 2 s to memorise it If the memorisation procedure is successfu...

Страница 24: ...g the manoeuvre ensure that there is voltage on the FLASH terminal of the flashing light as this is intermittent the voltage value is not significant TABLE 10 fig 45 10 5 TROUBLESHOOTING Table 10 give...

Страница 25: ...ible faults see Table 13 47 D E F C B A LED ECSBus A Off On One flash per second 2 long flashes 1 flash every 5 seconds Series of flashes separated by a pause Quick flash Status Fault Serious fault Ev...

Страница 26: ...cond 2 flashes per second Status Everything OK Everything OK The learning phase has not been carried out or there are errors in the memory data Device learning procedure underway Action Low speed sele...

Страница 27: ...specific fixing plates IP44 908 x 100 h 117 10kg Straight gearmotor for WG10SK swing gates TECHNICAL SPECIFICATIONS OF PRODUCT COMPONENTS The product WG20S is produced by Nice S p a TV I Mhouse S r l...

Страница 28: ...cts closure of the contact prompts the OPEN command For normally open and or 8 2kohm constant resistance type contacts or normally closed contacts with self learning of the normal status a variation w...

Страница 29: ...by the control units for MHOUSE automations 12V 21W fitting BA15 vehicle type lamp The device can only be connected to the terminals FLASH and AERIAL of the MHOUSE automation control units 20 50 C No...

Страница 30: ...nd marked Models WG10SK CL20S PH100 and FL100 conform to DIRECTIVE 2004 108 CE 108 EC OF THE EUROPEAN PARLIA MENT AND COUNCIL of 15th December 2004 regarding the approximation of member state legislat...

Страница 31: ...door until it is completely open and has come to a standstill Do not allow children to play near the door or with the con trols Keep the transmitters away from children Suspend the use of the automat...

Страница 32: ...an incorrectly balanced door may cause injuries 11 5 Remote control battery replacement fig 51 When the battery charge is low the transmitter range is reduced significantly When a key is pressed if l...

Страница 33: ...ial N Year of manufacture Location address Complies with the essential requirements of the following directives 2006 42 EC Machinery Directive 2004 108 EEC Electromagnetic compatibility directive 2006...

Страница 34: ......

Страница 35: ......

Страница 36: ...Mhouse is a commercial trademark owned by Nice S p a Nice S p a Via Pezza Alta 13 Z I Rustign 31046 Oderzo TV Italia Tel 39 0422 85 38 38 Fax 39 0422 85 35 85...

Отзывы: