Task
Frequency
Comment/Action
Clean
automatic relief
aperture
Monthly
The entire water separator/trap is attached to the pressure
regulator with a bayonet lock. Take off the water
separator/trap and clean the automatic relief aperture.
Lubrication
Every 2 weeks
for the first 6
months, then
quarterly
thereafter
The machine must be lubricated via the grease nipple
located on the centre shaft. MHM recommends “Berner
Heavy-Duty Multi-Purpose Grease” or a comparable grease
with the following technical specifications:
Water-repellent, lithium grease
Minimum melting point of approx. +195° C
Effective lubrication range from -20° C to +120° C
Clogged valve silencers cause lowered speed of pneumatic functions. In that
case the silencers must be changed.