Operating Instructions Synchroprint 5000
Operating instructions SP5000 V1-0.docx
Page 42 of 52
The following keys and knobs with a fixed function are available:
Key
Functional description
INLET MODE is used for the sequential start of a new print
job/run. It activates each selected print station/flash cure unit in
sequence when commencing a production run. After the first
complete printing cycle with all enabled print stations/flash cure
units, the startup mode will be turned off automatically.
OUTLET MODE is used to switch off the print stations one by one
when print job is finished.
SAMPLE starts a sample print. The desired amount can be
increased by pressing the button “Sample” more often. The actual
adjusted amount is displayed at “Produce”. The sample will
automatically perform the required inlet and outlet mode, the
manual adjustment is not necessary.
Pressing CLEAN initiates a “half-index” of the tables, particularly
useful for cleaning the screens. In clean position it is possible to
move the tables manually. Pressing CLEAN again moves the tables
back to its original position even when tables were moved
manually.
Starts an index and a working cycle. In Manual-mode only one
index and working cycle will be made. In Automatic-mode index
and working cycles start continuously.
Interrupts the running print job in Automatic-mode after the actual
working cycle is finished.
Turning SELECT changes the display or switches between different
input fields. Push knob so select actual field.
Turning SET changes a selected input field. Push knob to save
changes.