LIMITED WARRANTY

This device is classified as, and is only suitable for use as, a supplementary breathing apparatus (SBA) for aviation 
use.  It is intended to help supply the needed amount of oxygen for persons during flight altitudes where supple-
mental oxygen is needed.  This device is not suitable for any type of life support operations.  This device is not 
suitable for SCBA (Self Contained Breathing Apparatus), SCUBA (Self Contained Underwater Breathing Apparatus) 
or any medical operations.

Before it is put to use, it is the responsibility of any user who will use this device to become familiar with the 
operation and safety aspects of this device. Using the system improperly could cause failure and lead to possible 
property damage and/or personal injury. 

NOTICE OF NON-LIABILITY

Mountain High Equipment & Supply Company warrants your MH EDS O2D2-2G unit against defects in materials and 
workmanship for two (2) years from date of purchase invoice. The warranty is non-transferable. Should any part of the 
MH EDS O2D2-2G become defective within the warranty period return the EDS Unit with a description of what/why it 
is not functioning and we will repair or replace it, at our discretion, free of charge (you pay only shipping to MH). 

Contact MH at [email protected] for RMA# and Return Form

Return the Unit to:

Mountain High Equipment and Supply Company

Service Department

2244 SE Airport Way, Suite 100

Redmond OR 97756-7537

This warranty is non-transferable and only valid if Mountain High Equipment & Supply Company determines that 
the system and its components have not been damaged due to improper use, been submerged in fluids, dismantled 
or abused. Mountain High Equipment & Supply Company reserves the right to determine if repairs are to be done 
under warranty or at a nominal charge. 

To activate warranty coverage, you must complete and return your 

enclosed owner’s EDS Registration Card.

9

Содержание Pulse-Demand EDS O2D2-2G

Страница 1: ...atents Pending 800 468 8185 541 923 4100 Fax 541 923 4141 www MHoxygen com 2244 SE Airport Way Suite 100 Redmond OR 97756 7537 THE EDS O2D2 2GTM IS DESIGNED FOR EASY OPERATION CAREFULLY READ THIS INST...

Страница 2: ...hly oxidizing gas and can vigorously accelerate combustion It can provide a catalyst for spontaneous combus tion resulting in personal injury or death if not used properly and with caution DO NOT use...

Страница 3: ...he O2D2 with a Mountain High four port regulator FPR locate the oxygen input tube clear tube with a short red tube on one end and insert the Red tube into the Red Oxygen In connector on the O2D2 unit...

Страница 4: ...ries should be part of your pre flight inventory Regardless of use replace batteries annually DO NOT STORE THE EDS UNIT WHILE THE INLET IS UNDER PRESSURE Remove all sources of oxygen pressure and secu...

Страница 5: ...lthy person using a cannula at the given altitudes your needs may be different To determine whether you are receiving enough oxygen in a particular mode you will need to use a pulse oximeter available...

Страница 6: ...LOW FAULT EVENT The LED Red Light will flash on and off along with a Hi Lo audio chime for 2 seconds with every event NOTE The FLOW FAULT is not intended as a low or out of oxygen warning It is only i...

Страница 7: ...ously and leak oxygen To use the MH EDS O2D2 2G with a third party regulator or built in oxygen system with a pressure higher than 20 psi it is mandatory that you use the MH EDS IN LINE REGULATOR EDS...

Страница 8: ...ower Supply with the MH EDS O2D2 2G as other power supplies may not be compatible External 4 5 VDC Power Connector The MyGoFlightAdapter DualMicro is the top of the line DC charger for 12 28 volt syst...

Страница 9: ...2 2G unit against defects in materials and workmanship for two 2 years from date of purchase invoice The warranty is non transferable Should any part of the MH EDS O2D2 2G become defective within the...

Страница 10: ...to ensure your system is operating properly and upgraded to the latest specifications Any other parts replaced due to damage or field use would be subject to an additional charge Q How long should I e...

Страница 11: ...as the amount of dissolved CO2 reduces in the blood so does the need to respirate Unfortunately this also exacerbates hypoxia as less oxygen is inhaled and admitted into the blood as the body has no r...

Страница 12: ...EDS Audio Cable Aircraft Input TWO O2D2 2G UNITS DRIVING ONE INPUT The outputs from one O2D2 2G May NOT be tied to the outputs from another O2D2 2G In the case of installing two O2D2 2G units in an ai...

Страница 13: ...r we breathe to compensate for either a deficiency on the part of the individual or a de ficiency in the atmosphere in which we are breathing A person may have a respiratory or circulatory impairment...

Страница 14: ...c effects during the period in which oxygen is being used Because of the insidious nature of hypoxia a person already mildly hypoxic is very unlikely to even think of using oxygen equipment either int...

Страница 15: ...en Systems Transfillers Face Masks with and without mics AMSKM 2100 02 medium with mike Anti Bacterial Face Mask Wipes 00VEN 0077 00 EZ Breathe Quick Disconnect 19053 0009 00 Cylinders E Z Breathe Can...

Страница 16: ...ries are used Remove during long term storage External Power 4 5 VDC external power jack with auto battery disconnect with series diode is provided No over voltage protection is provided External Audi...

Отзывы: