AIRBRUSH DESCRIPTION 

B/SAFE  airbrush,  in  combination  with  the  B/SAFE  turbine,  allows  the  proper  nebulization  and  uniform 
distribution of the powdered liquid on the surfaces. The quantity of provided liquid can be regulated using 
the special adjusting srew placed at the top of the plastic receiver ( pos. 10).  Moreover, various types of 
spray can be obtained (oval vertical, oval horizontal or round) by rotating the locknut keeping down the fog 
effect. 
 

5.

 

TECHNICAL FEATURES 

The features of the airbrush ensure that the covering product is atomised and surround it in a jet of air so 
that it is softly deposited with precision on the support to be painted.  
 

6.

 

LIQUIDI PER LA SANIFICAZIONE/DISINFEZIONE UTILIZZABILI 

 

 
 
MGF recommends the use of hydrogen peroxide with a concentration of 3% (hydrogen peroxide Vol.10), of 
hydrogen peroxide with silver ions and quaternary ammonium salts. If you use concentrated liquids, always 
check the correct dilution percentage for nebulization. 
 
Our company is not responsible for any damage to people or things caused by the careless use of the device. 
 

7.

 

IMPROPER AND DANGEROUS USES 

                        

 
 
Our company is not liable for accidents resulting from the use of the equipment by NON-EMPLOYED and 
unqualified personnel or who use the same for purposes other than those indicated above. 
 

8.

 

SAFETY STANDARDS 

Warning! Respect the following safety regulations: 
Consider the environment of use: 

- The airbrush is used with nebulisable sanitizing / disinfectant liquids, keep in mind that these can be toxic 
- Provide good lighting of the treated room 
- Do not work indoors without adequate air exchange. 

Chemical considerations: 

- DO NOT USE with food or medicines; 
- Never point the spray gun in the direction of the human body or on animals. 

Store tools in a safe place: 

- Tools not in use must be stored in a dry and sheltered place; 
- Keep unauthorized people away, especially do not leave the tool in places accessible by children. 

Hold tools carefully: 

- Keep tools clean and always efficient by observing the instructions for use and maintenance. 
 

9.

 

SAFETY STANDARDS DURING USE 

- The airbrush must not be used in places related to the anti-deflagrating regulation; 
-  During  use  the  surroundings  are  to  be  free  of  inflammable  sources  such  as  flames,  smoking  cigarettes, 
sparks, white-hot cables, over-heated surfaces, etc.; 
- During use make sure that there is sufficient airing in the surrounding area and pay attention to the direction 
of the wind outdoors. 

 

The use of inflammable alcoholic  liquids, ethers or other highly flammable liquids is not allowed  

 

The use of the equipment for processes other than those indicated by the manufacturer can 
cause damage to the equipment and danger to the operator 

The  equipment  is  not  designed  for  the  processing  of  dangerous  materials,  explosives, 
herbicides and pesticides. 

We inform you that some of the liquids on the market can damage the surfaces of the treated 
equipment,  always  check  with  your  liquid  supplier  and  the  supplier  of  the  equipment  the 
suitability of the liquid used 

Содержание B/SAFE

Страница 1: ...LETTER AND USE OF THE MANUAL This use and maintenance manual is an integral part of the machine and the user must have knowledge of its content Although the main features of the machine described in this manual are not subject to change our company reserves the right to change those components details and accessories it deems necessary to improve the machine or to meet manufacturing or commercial ...

Страница 2: ...pply cable 9 Transport handle 7 TECHNICAL CHARACTERISTICS The blowing unit is fed by a single phase electric voltage between 220 230 240W and 50 60Hz The fan coupled motor generates an air flow which canalized into the feed pipe reaches the spray gun nozzle The high volume at low pressure provides the pulverization of the disinfection product and wrapped at the same time by the air blast deposits ...

Страница 3: ...sonnel Net plug In order to perform cleaning or maintenance operations always extract the net plug Avoid accidental starts Never transport the tools connected to the net when your fingers or hands are on the switch Supply extension cable In order to use it outdoors use only type approved extension cables for external use and replace them if they are damaged 11 SAFETY REGULATIONS DURING THE USE The...

Страница 4: ...s Weight Noise level double insulation 230V 50 60Hz 550W Two stage 1800 l min 64 cfm 0 13 bar 16 4 psi 10 C 40 C 300x220x310 mm 11 8x8 7x12 2 in 4 8 Kg 10 5 lb 75 dB double insulation 115V 60Hz 550W Two stage 1800 l min 64 cfm 0 13 bar 16 4 psi 10 C 40 C 300x220x310 mm 11 8x8 7x12 2 in 4 8 Kg 10 5 lb 75 dB 16 CONSIGLI IN CASO DI MALFUNZIONAMENTO Problema Probabile Causa Rimedio Turbine does not st...

Страница 5: ...ge our company reserves the right to change those components details and accessories it deems necessary to improve the machine or to meet manufacturing or commercial requirements at any time and without updating this manual immediately ALL RIGHTS ARE RESERVED The reproduction of any part of this manual in any given form without prior written authorization from our company is strictly forbidden 2 C...

Страница 6: ...he environment of use The airbrush is used with nebulisable sanitizing disinfectant liquids keep in mind that these can be toxic Provide good lighting of the treated room Do not work indoors without adequate air exchange Chemical considerations DO NOT USE with food or medicines Never point the spray gun in the direction of the human body or on animals Store tools in a safe place Tools not in use m...

Страница 7: ...m the treated surface by acting on the adjustment on the lid pos 10 it is possible to adjust the intensity of the nebulization quantity of liquid dispensed and reducing it it is possible to approach the treated surface without the risk of letting the nebulized liquid run off The excessive proximity of the spray gun to the treated surface will cause the liquid to pour out 11 MAINTENANCE To ensure f...

Страница 8: ...ed by incorrect use or assembly faults caused by external agents faults caused by negligence or poor maintenance WARRANTY DISCLAIMER The guarantee lapses in the event of arrears or other contractual defaults Repairs carried out under warranty do not interrupt the period of the same The warranty lapses fully if repairs or modifications to our equipment were made without our consent The unit is dism...

Отзывы: