MGF B/SAFE Скачать руководство пользователя страница 3

www.mgfcompressors.it

 – 

[email protected]

  

Ourcompany is not responsible for accidents deriving from the use of the machine by NOT TRAINED and 
not qualified personnel, for aims different from the ones indicated above. 
 

10.

 

 SAFETY REGULATIONS 

Warning!

 Respect the following safety regulations for the use of electric tools in order to protect yourself 

against electric shocks, dangers of lesions or fire. 

Consider the working environment: 

- Do not expose electric tools to rain and do not use them in moist or wet environments; 
- Provide for a good lighting: 
- Do not use electric tools in areas with risk of fire, near liquids or inflammable gases; 
- Do not work in closed environments without an adequate change of air. 

Protect yourself against electric shocks: 

- Avoid the contact with grounded components (hoses, hot plates, refrigerators, electric heaters); 

Keep the tools in a safe place: 

- The tools not currently used must be put in a dry and well-sheltered place: 
- Not trained people must keep away from the machine; above all, it cannot be placed in areas easily reachable 
by children; 

Do not use the cables for aims different from the expected ones: 

- Do not transport the tool by its cable and do not extract the plug by pulling the cable. 
- Protect the cable against oil, acids, heat sources and sharp edges; 

Take care of the tools: 

- Keep the tools clean and always efficient by following the use and maintenance instructions; 
- Check the plug, the cable and the switch periodically, and, in case of damages, they must be replaced by 
skilled personnel. 

Net plug: 

- In order to perform cleaning or maintenance operations always extract the net plug; 

Avoid accidental starts: 

- Never transport the tools connected to the net when your fingers or hands are on the switch; 

Supply extension cable: 

- In order to use it outdoors, use only type approved extension cables for external use, and replace them if 
they are damaged. 

 

11.

 

SAFETY REGULATIONS DURING THE USE  

 

The machine cannot be used in explosion-prone areas; 

Incendiary sources such as free flames, cigarette smoking, sparks, incandescent wires, and overheated 
surfaces, etc. must not be present in the environment during use; 

Make sure no liquids and/or substances evaporating during use are sucked up by the machine; 

Make sure the area is well ventilated during use, and consider the direction of the wind if you are using it 
outdoors; 

During  the  spraying,  always  place  the  machine  behind  the  operator  and  never  direct  the  jet  in  the 
direction of the machine itself; 

The  operators  must  wear  the  suitable  protections  during  the  spraying  operations  (protective  masks, 
gloves, clothing, etc.); 

Always check the supply voltage comparing it with the data reported on the plate; 

Switch off the machine immediately when you hear noises or you fear possible accidents; 

Use only original spare parts; 

The possible damaged units must be repaired only by authorized Customer Care Service. 

 
Our company declines every responsibility whatsoever in case the user does not observe said safety criteria; 
furthermore, it is not responsible for any kind of negligence when using the equipment or tampering. 
 

12.

 

INSTALLATION (see drawing B)  

1)

 

Using the two-pin connection (bayonet connection), connect the hose to the turbine side, by making 
it turn clockwise without 

Содержание B/SAFE

Страница 1: ...LETTER AND USE OF THE MANUAL This use and maintenance manual is an integral part of the machine and the user must have knowledge of its content Although the main features of the machine described in this manual are not subject to change our company reserves the right to change those components details and accessories it deems necessary to improve the machine or to meet manufacturing or commercial ...

Страница 2: ...pply cable 9 Transport handle 7 TECHNICAL CHARACTERISTICS The blowing unit is fed by a single phase electric voltage between 220 230 240W and 50 60Hz The fan coupled motor generates an air flow which canalized into the feed pipe reaches the spray gun nozzle The high volume at low pressure provides the pulverization of the disinfection product and wrapped at the same time by the air blast deposits ...

Страница 3: ...sonnel Net plug In order to perform cleaning or maintenance operations always extract the net plug Avoid accidental starts Never transport the tools connected to the net when your fingers or hands are on the switch Supply extension cable In order to use it outdoors use only type approved extension cables for external use and replace them if they are damaged 11 SAFETY REGULATIONS DURING THE USE The...

Страница 4: ...s Weight Noise level double insulation 230V 50 60Hz 550W Two stage 1800 l min 64 cfm 0 13 bar 16 4 psi 10 C 40 C 300x220x310 mm 11 8x8 7x12 2 in 4 8 Kg 10 5 lb 75 dB double insulation 115V 60Hz 550W Two stage 1800 l min 64 cfm 0 13 bar 16 4 psi 10 C 40 C 300x220x310 mm 11 8x8 7x12 2 in 4 8 Kg 10 5 lb 75 dB 16 CONSIGLI IN CASO DI MALFUNZIONAMENTO Problema Probabile Causa Rimedio Turbine does not st...

Страница 5: ...ge our company reserves the right to change those components details and accessories it deems necessary to improve the machine or to meet manufacturing or commercial requirements at any time and without updating this manual immediately ALL RIGHTS ARE RESERVED The reproduction of any part of this manual in any given form without prior written authorization from our company is strictly forbidden 2 C...

Страница 6: ...he environment of use The airbrush is used with nebulisable sanitizing disinfectant liquids keep in mind that these can be toxic Provide good lighting of the treated room Do not work indoors without adequate air exchange Chemical considerations DO NOT USE with food or medicines Never point the spray gun in the direction of the human body or on animals Store tools in a safe place Tools not in use m...

Страница 7: ...m the treated surface by acting on the adjustment on the lid pos 10 it is possible to adjust the intensity of the nebulization quantity of liquid dispensed and reducing it it is possible to approach the treated surface without the risk of letting the nebulized liquid run off The excessive proximity of the spray gun to the treated surface will cause the liquid to pour out 11 MAINTENANCE To ensure f...

Страница 8: ...ed by incorrect use or assembly faults caused by external agents faults caused by negligence or poor maintenance WARRANTY DISCLAIMER The guarantee lapses in the event of arrears or other contractual defaults Repairs carried out under warranty do not interrupt the period of the same The warranty lapses fully if repairs or modifications to our equipment were made without our consent The unit is dism...

Отзывы: