MGF B/SAFE Скачать руководство пользователя страница 5

www.mgfcompressors.it

 – 

[email protected]

  

 

 

 

 

Dear Customer, 
thank you for choosing this product. It is a leading reference point in the field of liquids nebulization. Our 
company  has  always  meant  great  reliability,  quality  and  safety.  All our  products  have  been  designed  and 
manufactured to guarantee the best performance ever. We feel confident we have further improved working 
standards and we are certain we have met all safety requirements, because our units have the DECLARATION 
OF CONFORMITY to European Directives 

THE MANAGEMENT 

 

1.

 

INFORMATION LETTER AND USE OF THE MANUAL 

This use and maintenance manual is an integral part of the machine and the user must have knowledge of its 
content. Although the main features of the machine described in this manual are not subject to change, our 
company  reserves  the  right  to  change  those  components,  details  and  accessories  it  deems  necessary  to 
improve  the  machine  or  to  meet  manufacturing  or  commercial  requirements,  at  any  time  and  without 
updating this manual immediately. 
ALL RIGHTS ARE RESERVED. The reproduction of any part of this manual, in any given form, without prior 
written authorization from our company, is strictly forbidden. 
 

2.

 

CHECK OF THE PURCHASED PRODUCT 

The original configuration of the airbrush must not be changed. Our original accessories and spare parts will 
always guarantee all safety standards. On receipt of goods check that: 
- The package is intact and is not damaged. 
- All the necessary documentation for the correct installation and use of the equipment is enclosed. 
Please inform the dealer in case of damages 

3.

 

STANDARD FITTED EQUIPMENT 

The airbrush with 0,5 mm nozzle also incluses: 

 

1 Locknut for nebilization 

 

1 spanner for nozzle replacement 

 

 

B

/S

A

F

E

 –

 T

U

R

B

IN

E

 A

IR

B

R

U

S

H

E

S

 

U

S

E

 A

N

D

 M

A

IN

T

E

N

A

N

C

E

 M

A

N

U

A

E

N

G

 

 

Содержание B/SAFE

Страница 1: ...LETTER AND USE OF THE MANUAL This use and maintenance manual is an integral part of the machine and the user must have knowledge of its content Although the main features of the machine described in this manual are not subject to change our company reserves the right to change those components details and accessories it deems necessary to improve the machine or to meet manufacturing or commercial ...

Страница 2: ...pply cable 9 Transport handle 7 TECHNICAL CHARACTERISTICS The blowing unit is fed by a single phase electric voltage between 220 230 240W and 50 60Hz The fan coupled motor generates an air flow which canalized into the feed pipe reaches the spray gun nozzle The high volume at low pressure provides the pulverization of the disinfection product and wrapped at the same time by the air blast deposits ...

Страница 3: ...sonnel Net plug In order to perform cleaning or maintenance operations always extract the net plug Avoid accidental starts Never transport the tools connected to the net when your fingers or hands are on the switch Supply extension cable In order to use it outdoors use only type approved extension cables for external use and replace them if they are damaged 11 SAFETY REGULATIONS DURING THE USE The...

Страница 4: ...s Weight Noise level double insulation 230V 50 60Hz 550W Two stage 1800 l min 64 cfm 0 13 bar 16 4 psi 10 C 40 C 300x220x310 mm 11 8x8 7x12 2 in 4 8 Kg 10 5 lb 75 dB double insulation 115V 60Hz 550W Two stage 1800 l min 64 cfm 0 13 bar 16 4 psi 10 C 40 C 300x220x310 mm 11 8x8 7x12 2 in 4 8 Kg 10 5 lb 75 dB 16 CONSIGLI IN CASO DI MALFUNZIONAMENTO Problema Probabile Causa Rimedio Turbine does not st...

Страница 5: ...ge our company reserves the right to change those components details and accessories it deems necessary to improve the machine or to meet manufacturing or commercial requirements at any time and without updating this manual immediately ALL RIGHTS ARE RESERVED The reproduction of any part of this manual in any given form without prior written authorization from our company is strictly forbidden 2 C...

Страница 6: ...he environment of use The airbrush is used with nebulisable sanitizing disinfectant liquids keep in mind that these can be toxic Provide good lighting of the treated room Do not work indoors without adequate air exchange Chemical considerations DO NOT USE with food or medicines Never point the spray gun in the direction of the human body or on animals Store tools in a safe place Tools not in use m...

Страница 7: ...m the treated surface by acting on the adjustment on the lid pos 10 it is possible to adjust the intensity of the nebulization quantity of liquid dispensed and reducing it it is possible to approach the treated surface without the risk of letting the nebulized liquid run off The excessive proximity of the spray gun to the treated surface will cause the liquid to pour out 11 MAINTENANCE To ensure f...

Страница 8: ...ed by incorrect use or assembly faults caused by external agents faults caused by negligence or poor maintenance WARRANTY DISCLAIMER The guarantee lapses in the event of arrears or other contractual defaults Repairs carried out under warranty do not interrupt the period of the same The warranty lapses fully if repairs or modifications to our equipment were made without our consent The unit is dism...

Отзывы: