Pressure change continuously: 

check air inside pump or plants. Check for dirty inside pump, valves good condition. Check filter and

gaskets.

Pressure sudden decreases:

 check for dirty filter and valves. Then check gaskets.

Pump is noisy:  

check for air suctions. Clean and move valve. Clean filter. Check water temperature. Check mechanical parts, in

particular ball bearings.

Water inside oil: 

change oil and look for damages on gaskets and rings. High humidity may cause this inconvenience.

Water losses from head: 

change gaskets and rings.

Oil  losses: 

change oil gaskets.

Switching on, there is “hum”, but the motor doesn’t turn: 

immediately turn off the motor, and verify if the pump isn’t locked. Check

if voltage in the electric net is corresponding with data on the label. Remember that long power cords may cause voltage losses. Verify
voltage at the pump plug.

The motor stops suddenly: 

thermal protection has switched off the pump for too high temperature. Check if voltage is correct, if pump

shaft isn’t blocked or hard to turn. Wait ten minutes, then restart pump. 

The motor don’t start:

 check electrical connections, plug and switch. If necessary, wait for thermal switch restarting.

Conformity Declaration

Conformity Declaration

MGF

MGF

 s.r.l. Via Chico Mendes, 8 – 43055 Mezzano Inferiore (PARMA) – ITALY declares that test pumps (art. 905650) responds to following

directives: 2006/42/CE, 2006/95/CE, 2004/108/CE, 2006/1907/CE, 2012/19/CE, 2011/65/CE.

Ing. Francesco Maioli

MGF

MGF

 srl

Diagrams

Diagrams

MGF

MGF

 srl –– Via Chico Mendes, 8 – 43055 Mezzani (PR) ITALY - Tel. +39 0521-818301| Fax +39 0521-818202 | E-mail: 

[email protected]

www.mgftools.com

  

www.nebulizzare.com

Содержание 905650

Страница 1: ...This manual has been written according to following directives 98 37 EEC 2006 42 EEC UNI EN 10893 Art 905650 Electric Test Pump 500bar User Manual rev 1 1 dated 29 09 2015 ...

Страница 2: ...ump is used incorrectly for a purpose for which it was not intended or is tampered TECHNICAL ASSISTANCE MGF TOOLS For any technical assistance contact us in one of the following ways phone 39 0521 818301 fax 39 0521 818202 e mail assistenza mgftools com We will serve you in the shortest possible time Material being shipped for repair must be authorized by the RMA binding condition for the withdraw...

Страница 3: ...and leave only it on the building site Don t leave the pump ON with TEST valve closed After a few minutes the bypass water increases temperature and this could damages gaskets Water temperature and air bubbles Water temperature and air bubbles can change pressure inside plant Consider these factors while testing big plants with big temperature differences High pressure water jets can cause damages...

Страница 4: ...net is corresponding with data on the label Remember that long power cords may cause voltage losses Verify voltage at the pump plug The motor stops suddenly thermal protection has switched off the pump for too high temperature Check if voltage is correct if pump shaft isn t blocked or hard to turn Wait ten minutes then restart pump The motor don t start check electrical connections plug and switch...

Отзывы: