Congratulations!   The   tool   you’ve   purchased   has   been   made   with   high   quality   materials   and   high   end   machining   technologies.

Compliance to our high quality standards will ensure you long time performances and reliability.

Read carefully this booklet and keep it in a safe place, to enjoy all the features of this professional tool and to work in an easy and safe

way.

Purpose of use

Purpose of use

This pump has been engineered for small transplanting and fillings and for plants test with water. The pump can work with all kind of
liquid with a maximum viscosity of 1.5 m Pa

s and with water solutions with PH between 7 and 12.

MGF

MGF

  refuses every responsibility for damages or bad working if the pump is used incorrectly, for a purpose for which it was not

intended or is tampered.

TECHNICAL ASSISTANCE MGF TOOLS 

For any technical assistance contact us in one of the following ways:

phone:

 +39 0521 818301

fax:

 +39 0521 818202

e-mail:

 

[email protected]

We will serve you in the shortest possible time.

Material being shipped for repair must be authorized by the RMA (binding condition for the withdrawal of any goods to be repaired).

TECHNICAL FEATURES

Dimensions

975 x 570 x 600 mm

Weight

132 Kg (140 w/ case)

Working Pressure

0 – 500 bar

Flow rate

7 – 15 L/min 

Inlet

clean water, 1 bar min

Max water temperature

60 °C

Motor

400 V ~ 50 Hz – 3 phases

Current - Power

29 A – 15 KW

Service

S1 – Class F

CosFi

0,8

Starting - Installation

Starting - Installation

Before starting operations, check if the pump has been labelled with serial number and technical data. Check all the optionals integrity

too. Keep package for further transports or stocking.

 

Содержание 905650

Страница 1: ...This manual has been written according to following directives 98 37 EEC 2006 42 EEC UNI EN 10893 Art 905650 Electric Test Pump 500bar User Manual rev 1 1 dated 29 09 2015 ...

Страница 2: ...ump is used incorrectly for a purpose for which it was not intended or is tampered TECHNICAL ASSISTANCE MGF TOOLS For any technical assistance contact us in one of the following ways phone 39 0521 818301 fax 39 0521 818202 e mail assistenza mgftools com We will serve you in the shortest possible time Material being shipped for repair must be authorized by the RMA binding condition for the withdraw...

Страница 3: ...and leave only it on the building site Don t leave the pump ON with TEST valve closed After a few minutes the bypass water increases temperature and this could damages gaskets Water temperature and air bubbles Water temperature and air bubbles can change pressure inside plant Consider these factors while testing big plants with big temperature differences High pressure water jets can cause damages...

Страница 4: ...net is corresponding with data on the label Remember that long power cords may cause voltage losses Verify voltage at the pump plug The motor stops suddenly thermal protection has switched off the pump for too high temperature Check if voltage is correct if pump shaft isn t blocked or hard to turn Wait ten minutes then restart pump The motor don t start check electrical connections plug and switch...

Отзывы: