Hose connection:

 screw the high pressure hose and the suction hose (through quick connector or 1/2” F thread) without using too

high torque.

Water plant connection:  

incoming water must be clean, without corrosives and, if possible, without limestone. Maximum allowed

temperature for water is 60 °C. Connection requires a hose of at least ½” (Ø 13 mm internal) and 15 bar. Shorten if possible the
connection hose and eliminate every bottleneck on the hose. Minimum flow rate is 20 L/min.

Power connection: 

before connecting, check if the electric plant respects safety requirements and if it is able output required power.

The plant must have safety switch and earth grounding. Before connecting, turn off the pump. Don’t connect other loads on the same

point. Using long power cords, be sure that section of every cable is right for the current  flow, to avoid high temperatures and
dissipations.

Air blowing: 

to avoid pressure oscillation due to air inside plant, it’s due eliminating all air inside plant to allow complete water plant

filling.

Working suggestions and Warnings

Working suggestions and Warnings

Pressure regulation device w/double valve allows working at desired pressure before filling the system. 

Close the tap on the high pressure hose: read pressure = 0 on the test gauge

Turn fully counterclockwise the the pressure regulator

Start the motor switching the main switch

Turn the pressure regulator clockwise, until you reach the desired working pressure on the gauge on the pump (setting gauge)

Open the tap on the pressure hose

Fill the system 

Close the tap and stop the pump

Close “TEST” valve, as the desired pressure has been reached. 

In this way you’ll cut off from test the pump and all the input

plant, while you can continue checking pressure on gauge.

 

For long time tests, you can disconnect HELP instrument from the pump and

leave only it on the building site.

Don’t leave the pump “ON” with “TEST” valve closed.

 After a few minutes the bypass water increases temperature and this could

damages gaskets.

Water temperature and air bubbles: 

Water temperature and air bubbles can change pressure inside plant. Consider these factors

while testing big plants with big temperature differences.

High pressure water jets can cause damages if used improperly

. Avoid starting pump without connecting it to the plant.

High pressures can bring to explosions:  

always consider your working pressure range before starting the test on the system:

otherwise you may damage things and persons

Work always in a safe way:

 respect general safety instructions, don’t let that water flows inside pump, use safety shoes and glasses.

Respect electrical safety instructions:

 maintenance and inspections are allowed only with the pump disconnected from power net.

Don’t stress the power cord, change it if damaged. Keep dry every electric part.

Check if high pressure hoses aren’t been damaged.

 If necessary, change them with original spare parts. Work on them only with

the motor turned off and with pressure discharged.

Ensure always motor ventilation. 

Verify that motor can have right air flow from the chassis.

Check 

inlet filter

 before every test.

Change oil

 after 50 hours and then after 100 hours. Use 

MGF

MGF

 mineral oil (see below). This maintenance timing can change with harder

working conditions.

Art.

Description

790051

Oil for 

MGF

MGF

 Pumps 5 L tank

790050

Oil for 

MGF

MGF

 Pumps 0,5 L bottle

If you don’t use the pump for a long time, and / or in low temperature countries, pump a little amount of no frost solution inside the
pump. This will ensure long life to gaskets. Before restarting pump, turn the shaft from the hole on the chassis to unblock, if necessary,

valves. 

Before starting, turn manually the shaft if necessary (gaskets glued).

Troubleshooting

Troubleshooting

The pump doesn’t reach the pressure:

 check in order: inlet filter, air inside pump, valves, inlet connection, gaskets.

Содержание 905650

Страница 1: ...This manual has been written according to following directives 98 37 EEC 2006 42 EEC UNI EN 10893 Art 905650 Electric Test Pump 500bar User Manual rev 1 1 dated 29 09 2015 ...

Страница 2: ...ump is used incorrectly for a purpose for which it was not intended or is tampered TECHNICAL ASSISTANCE MGF TOOLS For any technical assistance contact us in one of the following ways phone 39 0521 818301 fax 39 0521 818202 e mail assistenza mgftools com We will serve you in the shortest possible time Material being shipped for repair must be authorized by the RMA binding condition for the withdraw...

Страница 3: ...and leave only it on the building site Don t leave the pump ON with TEST valve closed After a few minutes the bypass water increases temperature and this could damages gaskets Water temperature and air bubbles Water temperature and air bubbles can change pressure inside plant Consider these factors while testing big plants with big temperature differences High pressure water jets can cause damages...

Страница 4: ...net is corresponding with data on the label Remember that long power cords may cause voltage losses Verify voltage at the pump plug The motor stops suddenly thermal protection has switched off the pump for too high temperature Check if voltage is correct if pump shaft isn t blocked or hard to turn Wait ten minutes then restart pump The motor don t start check electrical connections plug and switch...

Отзывы: