5 Maintenance

5 Maintenance

Use the gauge glass to check the oil level every time before start-up (please observe horizontal position). The oil level should be 
half way up the gauge glass. 

Check that the filter is clean every time before start-up!

Please ensure that the water is clean when taking in at outside locations. The hose cross-section must be at least ½“ =12.7 mm 

The first oil change should take place after 500 operating hours. Further oil changes after 1000 operating hours in each case. Type  
of oil: SAE20/30. 
Warranty of any kind shall expire if the pump is operated without a universal safety valve or if the limiting values for temperature 
and speed are exceeded ("Guidelines for fluid spray guns"). 
The safety valve must be set in such a way that the maximum operating pressure cannot be exceeded by more than 10%

For 905550 only: 
Please note: Be sure to observe the information in the attached petrol motor instruction manual! The petrol motor should be  
serviced and cared for in accordance with the manufacturer’s instructions. (or contact the S.A.T. Technical Assistance Service - 
General Information section).

6 Repair

6 Repair

Both maintenance and repair must only be carried out by qualified and 

MGF

MGF

 approved personnel.

7 Disposal

7 Disposal

Components of the unit are recyclable material and should be put to recycling. For this purpose registered and certified recycling 
companies are available. For an environmental friendly disposal of the non-recyclable parts (e.g. electronic waste) please contact 
your local waste disposal authority. Oils and lubricants: Only specialist companies are authorized to dispose of old oils. Old oils and 
contaminated oils must be stored and disposed of in sealed, oil-resistant containers (metal drums). Defective electrical appliances 
and machines that cannot be repaired must be opened and cleaned to remove the remaining oil. Oil troughs must be cleaned so 
that there are no traces of oil. No oils (even very small amounts) may be allowed to enter the ground! 

Waste from maintenance work: Regulations issued by the responsible national and regional authorities for disposing of refuse must 
be observed. These are available from the local environmental authority. If in doubt, waste from maintenance work such as 
cleaning and rinsing agents, cloths etc. must be disposed of as special category waste by communal collecting points. Waste that 
can be recycled must be separated on the basis of material groups and sent for suitable recycling! For EU countries only: Do not 
dispose of electric tools with domestic waste. In accordance with European Directive 2012/19/EC on waste electrical and electronic 
equipment and its implementation as national law, electric tools that are no longer serviceable must be collected separately and 
utilised for environmentally compatible recycling.

10

MGF

MGF

 srl –– Via Chico Mendes, 8 – 43058 Sorbolo Mezzani (PR) Italy – Tel. +39 0521-818301 Fax: +39 0521-818202 

E-mail: 

[email protected]

  

www.mgftools.com

 – 

www.nebulizzare.com

Содержание 905500

Страница 1: ...Sorbolo Mezzani PR Italy Tel 39 0521 818301 Fax 39 0521 818202 E mail info mgftools com www mgftools com www nebulizzare com Art 905500 Water Jet Art 905550 Motor Jet High Pressure Water Jet User Manual Rev 3 15 02 2022 Art 905500 Art 905550 ...

Страница 2: ... all responsibility for malfunctions and or consequences arising from incorrect operations by the User Even partial reproduction of this manual in any form is prohibited without the written authorization of the Manufacturer The Manufacturer reserves the right to make improvements or changes to its instruments at any time and without notice 2 MGF MGF srl Via Chico Mendes 8 43058 Sorbolo Mezzani PR ...

Страница 3: ...F MGF srl General informations General informations TECHNICAL ASSISTANCE SERVICE S A T For any form of technical assistance you can contact us in one of the following ways telephone 39 521 818301 fax 39 521 818202 e mail assistenza mgftools com We will try to serve you as soon as possible It is possible to take advantage of an on site assistance service free of charge for interventions under warra...

Страница 4: ...h of children 10 Do not overload your machine Work is better and safer within the performance range indicated 11 Use the right tool Don t use low performance machines for heavy duty jobs Do not use the electric tool for purposes for which it was not intended 12 Wear proper clothing Do not wear loose clothing or jewellery as they can get caught in moving parts When working outdoors wear slip resist...

Страница 5: ...only if a anti return flow valve with an aerator is fitted in the inlet pipe before the machine 2 Hose lines are to be guided in such a way that they are not pinched or damaged by bodies with sharp edges Extended tensile and bending stress to the hose lines is to be avoided 3 The operator must ensure that the proper condition of the important parts and safety devices is checked every time before t...

Страница 6: ...ing pipes drains downpipes house service connections rain downpipes and for cleaning work in general as well as for water testing Working pipe diameter is variable accordingly to the nozzle installed on top of the pipe All models are equipped with Variable pressure regulator from 0 to rated max pressure High quality pump with 3 ceramic pistons running in an oil bath run dry safe stainless steel va...

Страница 7: ... temperature is 60 C POWER SUPPLY CONNECTION Plug the line cord plug into the socket except on 905550 Please observe the necessary fuse protection in accordance with the current consumption of the devices Power supply shall be equipped with a safety switch with a sensibility of 10mA When using cable drums be sure to unwind the cable completely MACHINE PREPARATION Unroll the high pressure hose with...

Страница 8: ...unction 3 3 Actuation valve UNCLOGGING CLEANING function 4 4 Pump pressure regulator 5 5 Pulsation generating valve 8 MGF MGF srl Via Chico Mendes 8 43058 Sorbolo Mezzani PR Italy Tel 39 0521 818301 Fax 39 0521 818202 E mail info mgftools com www mgftools com www nebulizzare com ...

Страница 9: ...he device or deactivate the motor with reference to article 905550 see the instructions for the internal combustion engine supplied or contact the S A T Technical Assistance Service General Information section Stop the supply of water turn off tap Venting Press the dead man s switch shortly to relieve the pressure After using the washing lance unscrew the washing lance from the high pressure hose ...

Страница 10: ...ies are available For an environmental friendly disposal of the non recyclable parts e g electronic waste please contact your local waste disposal authority Oils and lubricants Only specialist companies are authorized to dispose of old oils Old oils and contaminated oils must be stored and disposed of in sealed oil resistant containers metal drums Defective electrical appliances and machines that ...

Страница 11: ...8 Drawings 8 Drawings Art 905500 11 MGF MGF srl Via Chico Mendes 8 43058 Sorbolo Mezzani PR Italy Tel 39 0521 818301 Fax 39 0521 818202 E mail info mgftools com www mgftools com www nebulizzare com ...

Страница 12: ...Art 905550 12 MGF MGF srl Via Chico Mendes 8 43058 Sorbolo Mezzani PR Italy Tel 39 0521 818301 Fax 39 0521 818202 E mail info mgftools com www mgftools com www nebulizzare com ...

Страница 13: ...own responsibility that the product Water Jet and Motor Jet cod 905500 and 905550 from serial number 2022029999 is in compliance with the Machinery Directive 2006 42 EC MGF MGF srl 13 MGF MGF srl Via Chico Mendes 8 43058 Sorbolo Mezzani PR Italy Tel 39 0521 818301 Fax 39 0521 818202 E mail info mgftools com www mgftools com www nebulizzare com ...

Страница 14: ...14 MGF MGF srl Via Chico Mendes 8 43058 Sorbolo Mezzani PR Italy Tel 39 0521 818301 Fax 39 0521 818202 E mail info mgftools com www mgftools com www nebulizzare com ...

Отзывы: