difficult testing operations.

(10)In this case, ensure that inlet hose and bypass hose aren’t too close, in order

to avoid turbolences inside tanks.

(11)Air accumulator is loaded at 5÷6 bar, corresponding to max working pressure

of the pump. This tank avoids pressure oscillating at outlet. For this reason, 
to have the best pressure control, periodically check pressure inside air tank, 

by connecting a car wheels air gun to the valve on the head. If necessary, 
load the accumulator to 5÷6 bar max.

(12)We suggest to keep max suction height under 3 m. Use always hoses without

bendings and, if possible, filled with water.

(13)

Pump can be started only with bypass valve completely opened. In this way 

you won’t load (and overheat) without reason the motor during start 

transient. The connection of the high pressure hose must be made without 
high torque, in order to not damage connection threads.

Working

Working

Plant Tests

Put the pump on a horizontal surface. Connect test instrument to the plant. Open test

valve and bypass valve. 
When the water flow begins, close bypass valve and fill the plant with the water, and 
outflow all air or gases in general inside plant.

Turn press valve in order to reach requested pressure, then close test instrument 
valve and open bypass lever.
During the test you can leave test instrument on the plant and disconnect the pump. 

Using differents test instruments, it’s possible to make different parallel test using 
only a pump.

Fillings and Transplantings

Check always chemical compatibility before working. The std version is equipped with
Nitrile gaskets. Inlet and bypass hose must be put into the tank with the liquid to be 
transplanted. High pressure outlet hose must be connected to the system to be filled 

(i.e. solar panel system) or into the tank to be filled. It’s possible to leave inlet filter 
only if the working fluid is clean and without suspended particles.
Before starting pump, open completely bypass pump.

After Use

Cleaning: To preserve good working performance, after working, you may clean the 

pump by pumpung for 2-3 minutes clean water, then leaving the pump on without 

inlet flow, to dry the head inside.

Low Temperatures: Avoid frozen water inside the pump: it can damage pump and 

gaskets. After use, dry the pump and/or pump inside a no-frost solution (water and 

3

Содержание 905100

Страница 1: ...1 Art 905100 ELECTRIC PRESSURE TESTER User Manual Rev 1 0 of 02 08 2016 ...

Страница 2: ...h a serial id number and technical data 2 Check all working contidions and verify if they allows you to work in safe way lighting humidity temperature wind 3 Before connecting to the mains check that electrical requirements reported on the label are satisfied by the mains same Connect to a plant equipped with differential switch or similar safety devices If you need to use long power cords ensure ...

Страница 3: ...lose bypass valve and fill the plant with the water and outflow all air or gases in general inside plant Turn press valve in order to reach requested pressure then close test instrument valve and open bypass lever During the test you can leave test instrument on the plant and disconnect the pump Using differents test instruments it s possible to make different parallel test using only a pump Filli...

Страница 4: ...ng maintenance causing damages to peoples and things Working the pump has an acoustical power lower than 83dBA This is an electrical tool respect general electrical devices safety instructions disconnect the pump after working and before maintenance don t let water enter in contact with the electrical parts The pumps guarantee loses its validity if this booklet instructions aren t respected Mainte...

Страница 5: ...If necessary contact our technical helpdesk The pump doesn t turn Check if the bypass valve is open Check starting capacitor If necessary contact our technical helpdesk The pump cannot reach requested pressure Verify for losses on plant close pressure regulation valve If necessary clean inlet filter In a second time check for valve wearout or dirty If you need one use only original spare parts Low...

Страница 6: ... A A Benzyl A D Butyl A A Diacelone D D Ethyl A A Hezyl A A Isobutyl A C Isopropyl A C Methyl C B Octyl A B Propyl A A A very good B good C poor D not allowed Conformity Declaration Conformity Declaration The Manufacturer MGF MGF srl Via Mendes 8 43055 Mezzani PR ITALY declares that pressure testers 905100 are manufactured according with 2006 42 EEC regulations ing Francesco Maioli 6 ...

Отзывы: