software supplied with 
Pulsar ESV+

Rack

To meet the different operating environments of your
UPS, Pulsar ESV+

Rack includes 2 MGE UPS SYS-

TEMS software programs:

ESV-Driver software for Windows;

Network based Solution-Pac™ power management

software.

ESV-Driver for Windows

ESV-Driver for Windows provides communication with the
UPS from a simple Windows workstation. ESV-Driver is
compatible with Windows 3.1x and Windows 95/98, for
communication with the UPS via a serial connection for
various needs:

personalization of the UPS operating mode: the

ESV-Tuner utility, can be used to change certain UPS
operating parameters if the standard factory settings are
not ideal for the operating conditions.

It is possible to modify the output voltage, battery-test fre-
quency, startup and shutdown sequences, etc.;

Solution-PacTM for networks and
multi-server systems

Protection by UPS is only complete and effective if com-
bined with powerful software functions which warn users
and the operator of any power supply problem, automate
system shutdown, supervise and remotely control the
UPSs. MGE UPS SYSTEMS created Solution-PacTM for
this purpose. Solution-PacTM combines all these func-
tions in a single CD-ROM, usable in local or remote
mode (TCP/IP and SNMP), and covering the main net-
work environments.
Solution-PacTM is the ideal solution for protecting net-
works and multiserver systems.
Solution-PacTM on a single CD-ROM contains everything
needed to safeguard one or more systems and to super-
vise one or more UPSs from a local or remote station.
Solution-PacTM includes SNMP proxy agents, system
shutdown software, and supervision software.

Solution-PacTM is a powerful and upgradable  software
tool which provides all the supervision, control and safety
functions associated with a UPS:

graphic display of the UPS,

remote control of the UPS and output receptacles,

user alarm of problems, 

recording of events in log files,

automatic system shutdown and restart,

local or remote supervision of UPSs and ancillary

devices,

transmission of UPS information and alarms to any

SNMP supervisor.

paging / e-mail capabilities

multiple server shutdown in heterogeneous environ-

ment.

Platforms supported:
Windows 3.1, 95, 98, NT, Novelle Netware, OS/2, Linux,
Mac/OS, Sun Solaris, HP/UX, IBM Aix, Dec Unix and
Open VMS, Silicon Graphics, IRIX.

Содержание Pulsar ESV 11+Rack

Страница 1: ...user manual Pulsar ESV 8 Rack 11 Rack 14 Rack 22 Rack 1 2 www mgeups com...

Страница 2: ...ou require assistance Yours truly MGE UPS SYSTEMS Federal Communications Commission FCC Statement Note this equipment has been tested and found to comply with Part 15 of the FCC Rules These limits are...

Страница 3: ...et shall be near the equipment and easily accessible To isolate Pulsar from AC input turn unit off and remove the plug from the utility power outlet if Pulsar is to be stored for a long time it is rec...

Страница 4: ...MGE UPS SYSTEMS Pulsar ESV 8 Rack 11 Rack 14 Rack 22 Rack 86 153523 00 4...

Страница 5: ...MGE UPS SYSTEMS Pulsar ESV 8 Rack 11 Rack 14 Rack 22 Rack 86 153523 00 5 general contents discover Pulsar 6 illustrations and features key diagram introduction getting started operation 11...

Страница 6: ...2 Rack 86 153523 00 6 front view of ESV 8 Rack 11 Rack 14 Rack 22 Rack rear view of ESV11 Rack 14 Rack 1 2 MGE UPS SYSTEMS Inc Vac IN 8 15 10 7b 7a 7 6 9 17 5 16 12 1 2 1a 1b 1c 1d 1e 1f 1g 2 3 MGE UP...

Страница 7: ...00 7 13 The indispensable companion sofware for your UPS L indispensable compl ment logiciel de votre onduleur solution pac rear view of ESV8 Rack 1 2 MGE UPS SYSTEMS Inc T 10A 125V I max 6 5A Vac OUT...

Страница 8: ...ator light flashing quickly only overload 1d yellow indicator light flashing quickly only operating on booster or fader mode 1e yellow indicator light flashing quickly only plug 2 not powered 1f yello...

Страница 9: ...on cards key to diagrams page 6 to 8 2 function button switches off audio warning device or measures load charge percentage with utility power 3 ON OFF switch 4 utility input receptacle 5 utility powe...

Страница 10: ...tomate system shutdown supervise and remotely control the UPSs MGE UPS SYSTEMS created Solution PacTM for this purpose Solution PacTM combines all these func tions in a single CD ROM usable in local o...

Страница 11: ...liminary checks 13 connections 13 power connections 13 serial connections 13 computer network protection 13 communication 14 operation 15 starting up with utility power 15 starting up without utility...

Страница 12: ...e alarm climate control fault intrusion etc additional communications options SNMP administration MGE has the most com plete offering for the administration of a group of UPSs using the SNMP protocol...

Страница 13: ...onnect the other end to a serial port of a computer system computer network protection If you wish to use the network line filtering functions Ethernet for example use a cable of the RJ45 type Connect...

Страница 14: ...To install ESV Driver connect the serial cable supplied to COM1 to COM4 set up by ESV Tuner seri al port of your computer equipped with Windows 3 1 or 95 98 on the one end and to the serial Pulsar ES...

Страница 15: ...es are not powered normal operation indicator lights and audio warning device test press button on off press button 3 1 sec automatic sequence your main devices are supported by the battery Output rec...

Страница 16: ...d normal operation with battery autonomy indicator lights and audio warning device test press button 3 1 sec automatic sequence your main devices are supported by the battery Output receptacles 1 and...

Страница 17: ...power the fader and booster functions are used to keep the output voltage range Umax Umin compatible with the supply operating range of your application this operating range can be configured via the...

Страница 18: ...the utility power returns Pulsar switches to normal operation x min x min 5 min 0 min if Pulsar is operating off load device switches off Pulsar switches off automatically low battery warning indicati...

Страница 19: ...reset ther mal breaker 6 re start Pulsar A battery test is carried out while Pulsar is in start up phase then automatically every 7 days overhaul times adjustable using ESV Driver If a battery fault...

Страница 20: ...to avoid any data loss use a screwdriver to remove the cover on the right side of the UPS ESV Rack use a screwdriver to remove horizontal metal plate holding the batteries For ESV22 Rack remove termi...

Страница 21: ...s with load on battery voltage V single phase 120V 5 frequency F 50Hz 60Hz 1Hz auto selection output specifications with load on utility power voltage V see normal operation with utility power present...

Страница 22: ...k battery back up time Pulsar ESV 11 Rack 14 Rack battery back up time Pulsar ESV 22 Rack battery back up time t mn 0 2 tower servers desktop server tower server external mass storage tower server 12...

Страница 23: ...ance of original two 2 year warranty or 90 days whichever is greater Customer must first obtain a Return Material Authorization number RMA from MGE s Sales Administration department The RMA must be cl...

Страница 24: ...Product names mentioned herein may be trademarks and registered trademarks of their respective companies Published by MGE UPS SYSTEMS 02 99 Austria 0660 6215 Belgium 0800 7 2189 China Hong Kong 852 2...

Отзывы: