4. Dimensions
•
AIRUNIT GEMINI ventilation unit
(
all dimension information in mm
)
AIRUNIT Ventilator unit
Air output
5 | 10 | 21 | 30 m³/h in heat recovery mode /
40 m³/h in exhaust air mode
Sound power level
23 | 34.5 | 49 | 55 dBa / 49 dBa in exhaust air mode
Sound pressure level at a distance of 1 meter
15.2 | 26.5 | 41.0 | 47.2 dBa / 41.0 dBa in exhaust mode
Power consumption
1.0 | 1.7 | 2.7 | 4.0 Watt / 2.7 Watt in exhaust air mode
Control
4 power exhaust air operation
Filter category
Filter ISO Coarse 50% (G3), regenerative
Supply voltage
230 V / 50 Hz
Heat recovery
up to 98
%
Remote control
yes
DIBt Zulassung
in preparation
Netzspannung
200-250 AC / 50-60 Hz
Ventilator
12 V / EC-, direct current
Ventilation unit
155 x 300 mm (W x H)
Length 500 mm can be shortened up to 300 mm
Membrane keypad
power levels, winter & summer operation, filter level indicator
Power unit
80 x 80 x 49 mm including cover frame, cannot be combined
with other switch ranges
223
4.1 Technical data
06
310
min.
305
min. 160
47
500 (can be shortened to 300)
360
230
Opening dimension wall breakthrough