INSTALLATION 

 

4-1  UNPACKING 

 

  

All the parts of the MEZZO stereo-microscope have been carefully packed so that they 
reach you in perfect condition. We recommend that you retain the original packaging as 
this will be needed if ever the device needs to be sent in, if you intend to store the item 
for a longer period, or if it needs to be transported to a technical service centre for 
servicing or repair. 

 

  

The packaging of the MEZZO comprises the following items: 

 

  

Microscope head with mount and LCD glare protection filter (4.2 Fig.1 - 10) 

 

  

Two eyepieces with eyepiece covers (4.2 Fig. 2 - 1) 

 

 

Supporting arm (for holding the welding hand-piece), with integrated LED light (4.2 
Fig.12) 

 

 

Bearing rod (4.2 Fig.1 -11) 

 

 

Base plate, for attaching the bearing rod (4.2 Fig.1 -13) 

 

 

Protective cover 

 

 

Tools for adjusting the focussing levels 

 

 

Remove and handle all microscope components with great care.  

 

 

Avoid touching the lenses and optical elements. Also avoid contact with dust, water or 
any other substances that could soil or damage the surface of the lenses and impair the 
quality of the image. 
 

 

4-2 

SETUP INSTRUCTIONS AND COMENCING WORK  

 

 

All stages of the microscope assembly must be carried out with great care. The 
individual parts must not be put together using excessive force. 

 

 

Mount the bearing rod (11) to the base plate (13), using the bolt that is included; tighten it 
with an open-ended spanner. Place upright, on a clean, flat, and stable surface. 

 

 

Slide the supporting arm (12) over the bearing rod (11) and secure it slightly above the 
middle of the rod, tightening hand tight. 

 

 

Slide the microscope head (8) and its mount with retaining screw (9) over the bearing rod 
(11), and secure it at about “3 fingers” width above the supporting arm for the hand-piece 
(12).  

 

 

Insert the eyepieces (1) with eyepiece covers, and secure them with the locking screw 
(4). 

 

 

Attach the “control lead for LCD glare protection filter (Shutter)” (15), to the back of the 
welding device. (Observe the guidelines in the instruction manual of the welding device). 

 

 

Connect the LED light with the PUK 3s. 
Insert the mains cable (16) into the connection socket marked “LED-Lamp 800 mA”, on 
the back of the welding device. 

 

 

Note! 

 

 

Always test that the LCD glare protection filter (Shutter) (6) is working correctly 
before you start welding. 

 

 

By pressing in the rotary knob 

Power

, of the “PUK U3” welding device, the 

shutter can be tested. During this process it will change from its clear setting to its 
dark setting, and back again. 

 

 

If the LCD glare protection filter (Shutter) doesn’t change from its clear to dark 
setting, then it must be exchanged straight away. No welding may be done unless 
the microscope has a fully functioning shutter. 

 

Содержание PUK 3s

Страница 1: ...y qualified personnel and then only for its designated use and in accordance with the guidelines here within The manufacturer accepts no responsibility and is in no way liable for damage caused by imp...

Страница 2: ...etting the viewing distance 7 5 3 Focussing 7 5 4 Dioptre settings 8 6 CARE AND MAINTENANCE 6 1 Maintenance of the optical components 8 6 2 Maintenance of the electrical components 9 7 TROUBLE SHOOTIN...

Страница 3: ...her application of the appliance other than the above stated is prohibited It is prohibited to use this apparatus out of doors Use only in dry surroundings 2 INTRODUCTION Arc welding without protectiv...

Страница 4: ...must be shut down and removed from the power supply it must also be secured against accidental re operation or activation It is likely and can be expected that a safe operation of the device is no lo...

Страница 5: ...ut together using excessive force Mount the bearing rod 11 to the base plate 13 using the bolt that is included tighten it with an open ended spanner Place upright on a clean flat and stable surface S...

Страница 6: ...n using these models it is necessary to use a transformer plug This is available as an optional extra Plug in the transformer plug into a suitable mains socket WARNING before connecting the stereo mic...

Страница 7: ...hat when both hands are resting on the hand rests 14 the work piece can easily be guided to the tip of the electrode Here remember to first correctly position the hand piece in the supporting arm Swit...

Страница 8: ...t eye open look through the left eye piece and adjust the focus by turning the dioptre adjustment 2 on the left eye piece tube 3 until the viewed object is in focus 6 CARE AND MAINTENENCE Under normal...

Страница 9: ...it flush with the underside of the supporting arm 7 TROUBLE SHOOTING PROBLEM CAUSE SOLUTION 7 1 PROBLEMS WITH ELECTRICAL COMPONENTS A The LED light doesn t work Cable is not attached Switch on the cor...

Страница 10: ...h the other 13 Always hold the microscope upright 8 TECHNICAL DATA 8 1 TECHNICAL INFORMATION MICROSCOPE LCD glare protection filter and LED light module for use only in conjunction with PUK precision...

Страница 11: ...posal system 10 EG CONFORMITY DECLARATION The Manufacturer Lampert Werktechnik GmbH Ettlebener Str 27 97440 Werneck Germany declares herewith that the following product Welding microscope with integra...

Отзывы: